Restorable Conventional Manual Alarm Call Point For Fire Safety Alarm System
|   | 
                                            ...l Point Rated operational voltage 9 to 33VDC Volts Non-polarized Relay contact rating 1A/30VDC Work temperature -10°C~+50°C Certification CE Humidity ≤95%. Size 86*89*37mm Weight 125 g Installation The call point has one 470ohm resistor is used on the...                                         
                                            Shenzhen Xinhe'an Technology Co., Ltd.
                                         
 | 
Green Emergency Door Release Break Glass , Manual Alarm Call Point Single Pole
|   | 
                                            Break Glass Fire Emergency Exit Release,SingLe PoLe Emergent Exit Button Products Feature 1. One-stop security solution provider, can be help you to save costs & times 2. Best quality products with very competitive price for your market 3. Professional ......                                         
                                            Shenzhen Vians Electric Lock Co.,Ltd. 
                                         
 | 
Break Glass Manual Fire Alarm Call Point
|   | 
                                            ...Manual Fire Alarm Call Point Parameter for break glass manual fire alarm call point: 1. Working voltage: 12/24VDC 2. Power: 10W 3. Switch state: Normally closed open (single or dual) 4. Color: Red, Green 5. Dimensions: 87mm*87mm*51mm . Materical: ABS plastic Color: Red / green/white/yellow (Optional) One year warranty Fire alarm break glass with manual call point Suitable for exit door or emergency door NC/NO/DPDT optional Manual......                                         
                                            Yiwu Yidun E-commerce Firm
                                         
 | 
Fire Fighting Equipment Break Glass Manual Fire Alarm Call Point
|   | 
                                            ... Resistance ≤0.2ohm Temp. Range -10℃~+50℃ Max. Relative Humidity ≤93RH±2% LED indicator green for working, red for alarm Type Can't be reset Color Red,Green,Yellow Use school/ hotel/ home..etc...                                         
                                            Mantern Industrial Co., Ltd.
                                         
 | 
Manual Vaseline Drip Point Instrument with 110mm Glass Test Tube 250rpm Mixing Motor and 400W Heater
|   | 
                                            ...Manual Drip Point Instrument The ST212AL manual Vaseline drop point analyzer fully complies with the standards of the 2025 Chinese Pharmacopoeia, British Pharmacopoeia, and SH/T0678 "Vaseline Drop Point Determination Method" for determining the drop point of Vaseline, that is, the temperature at which Vaseline reaches a certain fluidity under the specified test. Product model ST212AL Product Name Manual......                                         
                                            Shandong Shengtai instrument co.,ltd
                                         
 | 
ST212AL Manual Vaseline Drop Point Tester for Precise Vaseline Fluidity Temperature Determination in SH/t0678 Method
|   | 
                                            ...Manual Vaseline Drop Point Tester for Precise Vaseline Fluidity Temperature Determination in SH/t0678 Method ST212AL manual Vaseline drop point tester fully complies with the standards for determining the drop point of Vaseline in Chinese Pharmacopoeia, British Pharmacopoeia and SH / t0678 Vaseline drop point determination method in 2020 to determine the drop point......                                         
                                            Shandong Shengtai instrument co.,ltd
                                         
 | 
Manual Riser Zero Point Clamping 0.005mm Quick Change Clamping System
|   | 
                                            ...5-sided machining and can either be mounted directly and firmly on the machine table or set up and removed on a zero-point plate. It is available in round and rectangular versions in heights of 80 and 100 mm. The zero-point plates are pinned, aligned and...                                         
                                            Dongguan LiHeng machinery industry co.,ltd
                                         
 | 
SSMR100045P Chemical Acid Storage Cabinet Manual Close 3-point self-latching Steel Two door
|   | 
                                            ... with 1 ½” air space. 3-point self-latching (Non Sparking) doors. Reinforced 16-gauge all-welded construction. Two 2” vents with flash arrestors. Shelves and trays ......                                         
                                            SUPER SECURITY LTD
                                         
 | 
HONEYWELL TC806B1076 SMOKE DETECTOR For Fire Alarm System Point Photoelectric Smoke Fire Detector
|   | 
                                            ...: ● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER ● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more ! HONEYWELL TC806B1076 SMOKE DETECTOR For Fire Alarm System Point...                                         
                                            IRONMAN TECHNOLOGY CO., LTD
                                         
 | 
KLBH-H3 Gas Alarm With Shut Off Valve Detect Combustible Gas CO Alarm Set Point 10%LEL / 100PPM Semiconductor Sensor Type
|   | 
                                            KLBH-H3 Gas Alarm with shut off valve Introduction KLBH-H3 gas alarm is a kind of wall-mounted household gas alarm designed to detect the concentration of combustible and toxic gases or vapors using high quality air-sensitive component and manufactured wit......                                         
                                            Xi'an Kacise Optronics Co.,Ltd.
                                         
 | 
