MTL4514D MTL5514D Hazardous Area Switch Proximity Detector Interface
|
...SWITCH/ PROXIMITY DETECTOR INTERFACE The MTLx514D enables two safe–area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area. When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module. Switches......
SC Automation Limited
|
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
|
...Switch/Proximity Detector Interface The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area Hazardous-area inputs : Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors......
GREAT SYSTEM INDUSTRY CO. LTD
|
9V DC MTL5511 MTL Safety Barrier Switch Proximity Detector Interface
|
...Switch/Proximity Detector Interface The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area Hazardous-area inputs : Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR) Hazardous-area inputs Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors......
GREAT SYSTEM INDUSTRY CO. LTD
|
MTL5014 Switch/Proximity Detector Interface NAMUR/DIN 19234 Standards for Hazardous Area
|
MTL5014 SWITCH/ PROXIMITY DETECTOR INTERFACE The MTL5014 enables two safe-area loads to be controlled by a single switch or proximity detector located in the hazardous area. The safe- area interface has two changeover relays: output 1 and output 2. The ......
SC Automation Limited
|
MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum
|
...Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection Number of channels One Location of switch Zone 0, IIC, T6 hazardous area Div.1...
Achievers Automation Limited
|
MTL4511 MTL Instruments Switch/Proximity Detector Interface 1-channel, with line fault detection
|
...Switch/Proximity Detector Interface 1-channel, with line fault detection The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open MTL4511 1-channel safety barriers PROXIMITY DETECTOR INTERFACE......
Achievers Automation Limited
|
MTL4516 MTL Proximity Detector Interface
|
....cn (KLICK) QQ: 2851195450 Tel: 86-18020776792(KLICK) Skype:miyazheng520(KLICK) Product Details The MTLx516/C enable two safe-area loads to be controlled by a switch or proximity detector located in a...
MOORE AUTOMATION LIMITED
|
KFGTQ - DX401 Hazardous Area Multi - Gas Defender
|
KFGTQ - DX401 Hazardous Area Multi - Gas Defender Introduction The Hazardous Area Multi - Gas Defender: KFGTQ - DX401 is designed to safeguard hazardous areas. It supports various sensor types, including electrochemical, catalytic, and semiconductor. The ......
Xi'an Kacise Optronics Co.,Ltd.
|
Pepperl+Fuchs NBB8-18GM60-A2 Inductive Sensor 8mm NAMUR NO IP67 M30 Hazardous Area
|
Precise Sensing Capabilities The NBB8 - 18GM60 - A2, an inductive sensor by Pepperl + Fuchs, is engineered for accurate target detection. With an 8 - mm rated operating distance, it can precisely sense metallic objects within its range. Operating on a 3 -......
Xiamen ZhiCheng Automation Technology Co., Ltd
|
K1000 Series Gas Detector Controller Used In Monitoring Room 8/16/32 Channel
|
... controller for toxic or combustible gases. The controllers are easy to install and feature a large graphical LCD display and non-intrusive user interface for hazardous areas....
Nanjing Kelisaike Safety Equipment Co., Ltd.
|