| IEC 60320-1 (C14) | Main Inlet/Outlet | Flange Fixing | 2.8/4.8/6.3mm Tabs, Screw Terminals | PX0579, PX0580, PX0590, PX0596 | 10A, 250V (16A, 250V for C14 Class I, 20A, 250V UL/cUL for C19/C20) | -40C to +70C | +70C to +120C (depending on model) |
| IEC 60320-1 (C14) | Main Inlet/Outlet | Snap to Panel | 2.8/4.8/6.3mm Tabs, Screw Terminals, PC Spills | PX0575, PX0595, PX0598 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-1 (C14) | Main Inlet/Outlet | PCB Mounting | PC Spills | PX0580/PC, PX0575/PC | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-1 (C13) | Cable Mounting Connector | Rewirable | Screw Terminals | PX0587, PX0588, PX0597, PX0599 | 10A, 250V (16A, 250V for C19) | -40C to +70C | +70C to +120C (depending on model) |
| IEC 60320-1 (C14) | Fused Inlet | Flange Mount | 2.8/4.8/6.3mm Tabs, Screw Terminals, PC Spills | PF0001, PF0002, PF0030 | 10A, 250V AC (Max Fuse Rating: 2.5W/10A, 250V AC) | -40C to +70C | +70C |
| IEC 60320-1 (C14) | Fused Inlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs, PC Spills | PF0011, PF0016 | 10A, 250V AC (Max Fuse Rating: 2.5W/10A, 250V AC) | -40C to +70C | +70C |
| IEC 60320-1 (C14) | Twin Fused Inlet | Flange Mount | 2.8/4.8/6.3mm Tabs, PC Spills | PF0030 | 10A, 250V AC (Max Dissipation Per Fuse: 2.5W) | -20C to +70C | +70C |
| IEC 60320-1 (C14) | Twin Fused Inlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs | PF0033 | 10A, 250V AC (Max Dissipation Per Fuse: 2.5W) | -20C to +70C | +70C |
| IEC 60320-1 (C15 & C16) | Hot Condition Inlet/Outlet | Flange Mount | 2.8/6.3mm Tabs, Screw Terminals | PX0590, PX0597 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +120C |
| IEC 60320-1 (C15 & C16) | Hot Condition Inlet/Outlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs, Screw Terminals | PX0595, PX0597 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +120C |
| IEC 60320-1 (C18) | Class II Inlet/Outlet | Flange Mount | 2.8/4.8/6.3mm Tabs, Screw Terminals | PX0690 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-1 (C18) | Class II Inlet/Outlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs, PC Spills | PX0691 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-1 (C18) | Class II Fused Inlet | Flange Mount | 2.8/4.8/6.3mm Tabs | PF0006, PF0007 | 10A, 250V AC | -40C to +70C | +70C |
| IEC 60320-1 (C18) | Class II Fused Inlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs | PF0016 | 10A, 250V AC | -40C to +70C | +70C |
| IEC 60320-2-2 (E) | Class I Male Connector | Cable Mounting | Screw Terminals | PX0686, PX0686/SE | 10A, 250V AC | -40C to +70C | +70C |
| IEC 60320-2-2 (F) | Class I Outlet | Flange Mount | 2.8/6.3mm Tabs, PC Spills | PX0675, PX0675/PC | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-2-2 (F) | Class I Outlet | Snap Fit to Panel | 2.8/6.3mm Tabs, PC Spills | PX0695, PX0695/PC | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-2-2 (F) | Class I Outlet (Shuttered) | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs | PX0783 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-2-2 (F) | Class I Outlet (Shuttered) | Flange Mount | 2.8/4.8/6.3mm Tabs | PX0793, PX0793/1 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-2-2 (H) | Class II Outlet | Flange Mount | 2.8/4.8/6.3mm Tabs | PX0705 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| IEC 60320-2-2 (H) | Class II Outlet | Snap Fit to Panel | 2.8/4.8/6.3mm Tabs | PX0725 | 10A, 250V (15A, 250V UL & CSA) | -40C to +70C | +70C |
| Accessories | Retaining Clip | N/A | N/A | KT0006, KT0009, KT0012 | N/A | N/A | N/A |
| Accessories | Blanking Cover | N/A | N/A | PNo 14228 | Max. Working Voltage: 250V AC | -40C to +70C | N/A |
| Accessories | Insulation Boot | N/A | N/A | PNo 11328, PNo 11987, PNo 12075, PNo 14064, PNo 14317, PNo 14340 | Max. Working Voltage: 250V AC | -20C to +60C | N/A |