Fiber Amplifier Two-way fiber amplifier inside
Solenoid Valve Switch Counting: Provide switch counting data for
lifetime evaluation
Dual Switch Sensor ON/OFF Control: Support 2-way On/off switch
input, anti-shake or delay time can be set.
Automatic Switch Sensor Type Recognition: The controller can
recognize and adapt to both PNP and NPN-type switch sensors.
Type of Control Output: Push-pull type with OCP and SCP.
DC Control Output: The controller can output low voltage DC power
associated with the ON/OFF Control of the controller to drive a
solenoid or other external devices
Overvoltage Protection: If the input voltage exceeds the normal
working value, the controller will stop and put the error code. If
exceeds too much, the controller will be shut down automatically to
protect itself.
Overcurrent Protection: If the working current exceeds the rate
value, this port will be disabled to protect the circuit. while the
current returns a normal value. the function will recover
automatically.
Restorable Short Circuit Protection: If the output port is short to
24V or GND, the controller will set this port to a high impedance
state to protect the electronic component inside. while short
conditions are removed, this port will recover normal operation
automatically.