| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Dry Type Transformer |
|---|---|
| Brand Name: | HENTG Power |
| Certification: | CE |
| Usage: | Power,Electronic,Instrument,High Frequency,Distribution Transformer |
| Coil number: | Autotransformer,two,2,double winding,1-5 |
| Phase: | Three,Single,Single or Three phase |
| Coil structure: | Toroidal,EI,Custom / As your request |
| Frequency: | 50/60Hz,50Hz or 60Hz,50 Hz |
| Rated capacity: | 30-3000kva,315,63,3000,250 |
| Type: | Dry-type,Dry type,transformer,Auto,Cast Resin |
| Output voltage: | 200v/220/240/380v/400v/415v/440v,0.4KV,200V/220V/230V/240V/380V/400V/ 415V/440V/480V/600V/690V,415V,220Vac |
| Standard: | IEC60076,IEC,GB1094-1996; JB/T10088-2004; GB/T6451-2008; EQV,CNS,EC/ GB/T6451-2008 |
| Product name: | 3 phase Dry Type Electrical transformer 300kva,Dry type 10kva 440v to 220v three phase transformer,dry type 250 kva electrical transformer,transformer,35KV Grade Epoxy Resin Cast Dry Type Transformer |
| Material: | Copper,amorphmos alloy,Alumnium,EXPOY RESIN,Copper or aluminum |
| Rated voltage: | 11KV,35KV,600V,13.2KV,6.3KV |
| Input voltage: | 11kv/10.5kv/10kv/6.3kv/6kv,440Vac,200v/220/240/380v/400v/415v/440v,Customized as customers requirement,200V/220V/230V/240V/380V/400V/ 415V/440V/480V/600V/690V |
| High voltage: | 10kv,25kv,6kv to 11kv,5-35kV |
| Efficiency: | >98 %,High Efficient,≥95% |
| Low voltage: | 10 - 0.4/0.23kV,415v,440v,0.415kv |
| Color: | customized or red,Black,grey |
| Ambient temperature: | -15°C--- +45°C,-15 to +45°C,-15℃~+40℃ |
| Capacity: | 500VA ~ 1000kVA,1KVA-3000KVA,0.5 KVA to 1200 KVA Available |
| Company Info. |
| Hunan Hentg Power Electric Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
| Main Specification | |
| Transformer Type | dry type |
| Rated capacity | up to 8000kva |
| Rated voltage | up to 11kv |
| Frequency | 50/60Hz |
| Phase | 3 Phase |
| Winding material | Copper /Aluminum |
| Insulation class | H(180℃), C (220℃) |
| Vector group | Dyn11, YNd1d1, |
| Cooling | ANAN,GNAN |
| Protection Enclosure | IP00 to IP54 |
| Explosion-proof type | ExdIMb |
| Zone | Zone 1, Zone 2 |
| Tank Paining | C4 and C5 on resquest |
| Altitude | Max 2300m |
| standard | IEC, AS, EN, IEEE/ANSI, GOST |

Purpose and Conditions of Use
This productisused inmines with methane mixed gas. coal dust and
explosion risk as the powe distributiondevice ofcomprehensive
mechanized mining equipment in coal mines.
Service conditions:Theproductcan work continuously for a long time
under the following service conditions and rated capacity.
a.Altitude not exceeding 2000m;
b.The ambient temperature is not higher than +40 ℃;
c.The relative air humidity shall not exceed 95% (at+25℃);
d.Thereisnostrongturbulenceandvibrationandthe inclination of the
vertical plane does not exceed 15 degrees;
e.There is no gas and steam that can corrode metal and damage
insulation: f.A place without dripping water.
Structure Overview
Miningtameproofdrytypetranstormer KBSGis composed of box shell, box
cover, iron core
assembly,insulationassembly,high-voltagelead,low-voltage lead and
trolley for railway track.
The transformer box shellisanexplosion-proof structure with top
open cover. Four small hoisting mixers are setonthe boxcoverfor
oistingduringtheremoval of the box cover. Corrugated steel plates
are used onboth sidesofthe boxshellthickstee plates are used at the
bottom of the box, and connectingflanges areset on the high and
lowvoltage sides of the transformer to connect high and low
voltaaeswitchesourarae hoistna mixersarearranaed on the box shell
for the inteara hoisting of the transformer:Bothendsofthe boxshell
are welded with grounding bolts and "=" grounding marks for
connecting external grounding wires.
High andlowvoltageinterlockinglines and temperature control lines
inside the transformer are respectivelyconnected with high
andlowvoltage switches; PT100 platinum resistance or temperature
relavisusedfortemperaturecontroWhenthetemperature in the
transformer is too high. an ove temperature signal will be sent.
Transformer coreassemblyconsists ofcore,clipsinsulating parts and
so on. The iron core adopts high-qualitycold-rolled oriented
silicon steel sheet multi-stage stepping full-slope three-seam
aminationstructuretoreducenooadossandnooad current: Hiah
temperature anti-rust and moisture-proofpaint.Theclampis made of
channe steel, and the upper and lower tension adopts the pul
screwstructure.andmeasuresaretakento preventthe relative
dispacement of the iron core and the clamp, so as not to affect
theproductquality.The core insulation parts are made of domestic
high-quality insulation materials.
Transformerinsulation assemblyincludes mainlongitudinal insulation.
high and low voltage coils. coi pressingand
otherstructures.Themainlongitudinal insulation is made of
high-quality insulating materials High andlowvoltage
coilsadopttight winding technology, which improves the mechanical
strength o coils;HighandlowvoltagecoilsaremadeofC-grade insulating
paper wrapped oxygen free copper conductors.The electric field
aroundthe coils is uniform and the partial discharge is small. The
coil shal be pressed with pressing nail and porcelain pressing
block, and measures shall be taken to prevent looseness.
The high-voltagelead isled out by cableand thelow-voltage lead is
led out by cable or copper bus. The creepagedistanceand airgap
aregreater than the relevant provisions in GB3836.3-2000.Under
normaloperatina condtionssparksarcsanddanaeroustemperatures will
not occur. and the use is safe and reliable.
The trolleyisfixed atthebottom ofthe box with bolts and can be
disassembled. The trolley gauge is900/600mm.
|