Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home >

Proline Promass P 100 Coriolis flowmeter

Categories Electromagnetic Flow Meter
Brand Name: Endress+Hauser
Certification: CE
Place of Origin: Switzerland
MOQ: 1PCS
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1000 Piece/Pieces per Week negotiable
Delivery Time: 5-8 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Model Number: Proline Promass P 100
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range: Standard: –50 to +150 °C (–58 to +302 °F)Option: –50 to +205 °C (–58 to +401 °F)
Ambient temperature range: Standard: –40 to +60 °C (–40 to +140 °F)Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material: 1.4301 (304), corrosion resistant
Power supply: DC 20 to 30 V
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Proline Promass P 100 Coriolis flowmeter

"Specs at a glance
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)

Max. process pressure
PN 63, Class 300, 40K

Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)" "Field of application
Promass P 100 offers the enhanced performance of a bent tube meter and the drainability of a straight tube meter without any compromise. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications in sterile environments where space is a premium, Promass P 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.

Measuring principle operates independently of physical fluid properties such as viscosity or density

Dedicated for applications under sterile conditions in the life sciences industry.

Device properties

ASME BPE, 3-A and EHEDG conform & low delta ferrite

Electropolished measuring tube in 1.4435 (316L)

Fast recovery from CIP/SIP

Robust, ultra-compact transmitter housing

High ingress protection: IP69K

Local display available" "Benefits
Highest process quality – fully compliant to industry requirements

Fewer process measuring points – multivariable measurement (flow, density, temperature)

Space-saving installation – no in/outlet run needs

Space-saving transmitter – full functionality on smallest footprint

Time-saving local operation without additional software and hardware – integrated web server

Integrated verification – Heartbeat Technology" "Measuring principle
Coriolis

Product headline
Specialist for life sciences with an ultra-compact transmitter.
Dedicated to applications under sterile conditions in the life sciences industry.

Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP.

Transmitter features
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range
DN 8 to 50 (⅜ to 2"")

Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure
PN 63, Class 300, 40K

Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)

Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material
1.4301 (304), corrosion resistant

Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)

Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69

Display/Operation
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible

Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)

Inputs
None

Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply
DC 20 to 30 V

Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety
CE, C-Tick, EAC marking

Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation)

Pressure approvals and certificates
PED, CRN

Material certificates
3.1 material

Hygienic approvals and certificates
3-A, EHEDG, ASME BPE, ISPE, cGMP"