Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Chemical Machinery & Equipment >

Promass S 500 Coriolis Flowmeter with Hygienic Design, Self-Drainable Single-Tube System, and Multivariable Measurement

Categories Electromagnetic Flow Meter
Brand Name: Endress+Hauser
Certification: CE
Place of Origin: Switzerland
MOQ: 1PCS
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1000 Piece/Pieces per Week negotiable
Delivery Time: 5-8 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Model Number: Proline Promass S 500
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure: PN 40, Class 150, 20K
Medium temperature range: –50 to +150 °C (–58 to +302 °F)
Transmitter housing material: AlSi10Mg, coated; Polycarbonat
Hazardous area approvals: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product safety: CE, C-tick, EAC marking
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Promass S 500 Coriolis Flowmeter with Hygienic Design, Self-Drainable Single-Tube System, and Multivariable Measurement

Proline Promass S 500 Coriolis Flowmeter
Product Overview

The Promass S 500 is at the forefront in hygienic design, dedicated to applications in the food and beverage industry requiring optimal cleanability. Featuring a self-drainable single-tube system that ensures careful treatment of fluids, this innovative remote transmitter maximizes installation flexibility and operational safety in demanding environments.

Key Features
  • Easy-to-clean device with self-drainable single-tube system
  • Remote version with up to 4 I/Os
  • Multivariable measurement (flow, density, temperature)
  • Heartbeat Technology for integrated verification
  • 3-A and EHEDG conform for hygienic applications
Technical Specifications
Measurement Accuracy
Mass flow (liquid): ±0.10%
Volume flow (liquid): ±0.10%
Density (liquid): ±0.0005 g/cm³
Measuring Range
0 to 70,000 kg/h (0 to 2,570 lb/min)
Temperature Range
Medium: -50 to +150 °C (-58 to +302 °F)
Ambient: -40 to +60 °C (-40 to +140 °F)
Process Pressure
PN 40, Class 150, 20K
Nominal Diameter
DN 8 to 50 (⅜ to 2")
Measured Variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Materials & Construction
ComponentMaterial
Measuring Tube1.4435 (316L)
Connection1.4435 (316L); 1.4404 (316/316L)
Sensor Housing1.4301 (304), corrosion resistant
Transmitter HousingAlSi10Mg, coated; Polycarbonate
Electrical & Communication
Outputs
4-20 mA HART, 4-20 mA WirelessHART, Pulse/Frequency/Switch output, Relay output
Inputs
Status input, 4-20 mA input
Digital Communication
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP, PROFINET, Ethernet/IP, OPC-UA
Power Supply
DC 24 V, AC 100-230 V, AC 100-230 V / DC 24 V (non-hazardous area)
Certifications & Approvals
Hazardous Area
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product Safety
CE, C-tick, EAC marking
Hygienic
3-A, EHEDG, cGMP
Pressure
PED, CRN
Quality Promass S 500 Coriolis Flowmeter with Hygienic Design, Self-Drainable Single-Tube System, and Multivariable Measurement for sale