Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home >

Pointek CLS300 - Digital

Categories Water Quality Sensor
Brand Name: SIEMENS
Model Number: CLS300 - Digital
MOQ: 1pcs
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1000 Piece/Pieces per Week negotiable
Delivery Time: 5-8 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle: Inverse frequency shift capacitive level detection
Measured variable: Change in picoFarad (pF)
Output: Galvanically isolated
Protection: Against reversed polarity (bipolar)
Max. load current: 82 mA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Pointek CLS300 - Digital

Pointek CLS300 - Digital
Pointek CLS300 (digital version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features.

7ML5660-.....-....
CLS300,DIGITAL,ROD VERSN,THREAD/FLANGE
7ML5661-.....-....
CLS300,DIGITAL,CABLE VERSN,THREAD/FLANGE
7ML5662-.....-....
CLS300,DIGITL,HIGH TEMP ROD,THREAD/FLANG


Related products

Part NumberDescription
7ML1830-1APEASY AIMER II, ALUMINIUM, 3/4 INCH NPT WITH 1 INCH GALVANIZED COUPLING
7ML1830-1JACABLE GLAND, 1/2" NPT, General Purpose DIP
7ML1830-1JBCABLE GLAND, 1/2" NPT, explosion proof
7ML1830-1JCM20 x 1.5 cable gland (general use and dust explosion protection)
7ML1830-1JDCABLE GLAND, M20 x 1.5 HF, (EP)
7ML1830-1JETest Magnet
7ML1830-1JFAMPLIFIER / POWER SUPPLY DIGITAL VERSION
7ML1830-1JKLCD DISPLAY FOR CLS 200, DIGITAL
7ML1930-1AQOne metallic cable gland M20x1.5, rated -40掳C (-40掳F) to +80掳C (+176掳F) with integrated shield connection (available for PROFIBUS PA)
A5E01163688Kit, 316L stainless steel cable extension, 1 Meter, CLS300/LC300
A5E01163689Kit, 316L stainless steel cable extension, 3 Meter, CLS300/LC300
A5E01163690Kit, 316L stainless steel cable extension, 5 Meter, CLS300/LC300
A5E01163691Kit, 316L stainless steel cable extension, 10 Meter, CLS300/LC300
A5E01163693Kit, 316L stainless steel cable extension, 15 Meter, CLS300/LC300
A5E01163695Kit, 316L stainless steel cable extension, 20 Meter, CLS300/LC300
A5E01163698Kit, 316 stainless steel PFA cable extension, 3 METER, CLS300
A5E01163699Kit, 316 stainless steel PFA cable extension, 5 METER, CLS300
A5E01163700Kit, 316 stainless steel PFA cable extension, 10 METER, CLS300
A5E01163701Kit, 316 stainless steel PFA cable extension, 15 METER, CLS300
A5E01163702Kit, 316 stainless steel PFA cable extension, 20 METER, CLS300
A5E01163719Kit, 316L stainless steel rod 180 mm (7.09")
A5E01163720Kit, 316L stainless steel rod 330 mm (12.99")
A5E01163721Kit, 316L stainless steel rod 580 mm (22.83")
A5E01163722Kit, 316L stainless steel rod 830 mm (32.68")
A5E01163723Replacement electronics with driver, CLS300 standard. For use with rod or Cable versions with maximum length of 5 m
A5E01163724Replacement electronics with driver, CLS300 standard. For use with Cable versions with minimum length of 5 m
A5E01163725Replacement electronics with driver, CLS300 Digital. For use with rod or Cable versions with maximum length of 5 m
A5E01163726Replacement electronics with driver, CLS300 Digital. For use with Cable versions with minimum length of 5 m
A5E01163727KIT, Spare 316L stainless steel weight, CLS/LC300, cable version
A5E03251683Kit, CLS300 standard, transmitter

Benefits
Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section
Performs in extremely abrasive conditions because of solid rod construction
Push-button calibration, full-function diagnostics
High sensitivity allows installation in a wide range of liquids, solids or slurry applications
Integral LCD display allows for easy menu-driven setup
PROFIBUS PA communication (SIMATIC PDM compatible)

Application
Pointek CLS300 digital version provides an integral LCD display for stand-alone use, with PROFIBUS PA communication
(Profile version 3.0, Class B) when required. Solid-state switch alarm is standard.

The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry.

The fully potted electronics are unaffected by condensation, dust or vibration.

Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles.

The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions.

Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications

Configuration

Technical specifications

Pointek CLS300 Digital


Mode of operation


Measuring principle

Inverse frequency shift capacitive level detection

Input


Measured variable

Change in picoFarad (pF)

Output


Solid-state output


  • Output

Galvanically isolated

  • Protection

Against reversed polarity (bipolar)

  • Max. switching voltage
  • 30 V (DC)
  • 30 V peak (AC)
  • Max. load current

82 mA

  • Voltage drop

< 1 V, typical at 50 mA

  • Time delay (pre or post switching)

Programmable by user (0 ... 100 s)

Fail-safe mode

Min. or max.

Connection

Removable terminal block

Accuracy


Resolution


  • Min. sensitivity (pF)

1 % change in actual capacitance

  • Max. temperature error

0.2 % of actual capacitance value

Rated operating conditions1)


Installation conditions


  • Location

Indoor/outdoor

Ambient conditions


  • Ambient temperature

‑40 ... +85 °C (‑40 ... +185 °F)2)

  • Storage temperature

‑40 ... +85 °C (‑40 ... +185 °F)

Medium conditions

Liquids, bulk solids, slurries, interfaces, and applications with viscous materials

  • Relative dielectric constant εr

Min. 1.5

  • Process temperature

  • Rod/Cable version

-40 ... +200 °C (-40 ... +392 °F)2)

  • High Temperature version

-40 ... +400 °C (-40 ... +752 °F)

  • Process pressure3)

-1 ... +35 bar g (-14.6 ... +511 psi g)

Design


Material (enclosure)

Powder-coated aluminum with gasket

Degree of protection

Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68

Cable inlet

2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry)

Controls and displays


Local display

LCD

Configuration

  • Locally, using 3 button keypad (for standalone operation)
  • Remotely, using SIMATIC PDM (for installation on a network)

Power supply


Bus voltage (at process connection)

  • Standard: 12 ... 30 V DC
  • Intrinsically Safe: 12 ... 24 V DC

Current consumption

12.5 mA

Certificates and approvals


General Purpose

CSA, FM, CE, UKCA, RCM

Dust Ignition Proof

ATEX II 1/2 D, 2 D IP6X T100 °C

UKEX II 1/2 D Ex ia/tb [ia Da] IIIC TX
Da/Db

Flameproof Enclosure With IS Probe

ATEX II 1/2 G EEx d[ia] IIC T6 ... T4
ATEX II 1/2 D T100 °C

UKEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb
UKEX II 1/2 D Ex ia/tb [ia Da] IIIC TX Da/Db

Dust Ignition Proof With IS Probe

CSA/FM Class II, Div. 1,
Groups E, F, G

CSA/FM Class III T4

Intrinsically Safe4)

ATEX II 1 G EEx ia IIC T6 ... T4
ATEX II 1/2 D, 2 D IP6X T100 °C

UKEX II 1 G Ex ia IIC TX Ga
UKEX II 1/2 D Ex ia IIIC TX Da/Db

CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4

Non-incendive

CSA/FM Class I, Div. 2,
Groups A, B, C, D
CSA/FM Class II, Div. 2,
Groups F, G
CSA/FM Class III T4 or T6

Explosion Proof with IS Probe

CSA/FM Class I, Div. 1,
Groups A, B, C, D
CSA/FM Class II, Div. 1,
Groups E, F, G
CSA/FM Class III T4

Marine

Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5

Others

Pattern Approval (China)

Communication

PROFIBUS PA
(IEC 61158 CPF3 CP3/2)

Bus physical layer: IEC 61158-2 MBP-(IS)

Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B

FISCO field device


Quality Pointek CLS300 - Digital for sale
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0