Pointek CLS200 - Digital

Categories Ultrasonic Transducer Sensor
Brand Name: SIEMENS
Model Number: CLS200 - Digital
MOQ: 1pcs
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1000 Piece/Pieces per Week negotiable
Delivery Time: 5-8 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle: Inverse frequency shift capacitive level detection
Measured variable: Change in picoFarad (pF)
Output: Galvanically isolated
Protection: Against reversed polarity (bipolar)
Max. load current: 82 mA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Pointek CLS200 - Digital

Pointek CLS200 - Digital
Pointek CLS200 (digital version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS200 is ideal for detection of liquids, solids, slurries, foam, and interfaces and has the ability to tune out buildup on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features.

7ML5640-.....-....7ML5641-.....-....7ML5642-.....-....7ML5643-.....-....7ML5644-.....-....

Related products

Part NumberDescription
7ML1830-1JBCABLE GLAND, 1/2" NPT, explosion proof
7ML1830-1JCM20 x 1.5 cable gland (general use and dust explosion protection)
7ML1830-1JDCABLE GLAND, M20 x 1.5 HF, (EP)
7ML1830-1JETest Magnet
7ML1830-1JFAMPLIFIER / POWER SUPPLY DIGITAL VERSION
7ML1830-1JKLCD DISPLAY FOR CLS 200, DIGITAL
A5E01163672Spare Synprene gasket, enclosure version, for IP65 versions
A5E01163673Spare Silicone gasket, enclosure version, for IP68 version
A5E01163674CLS200/CLS300/LC300 Spare aluminum blind lid, for standard versions
A5E01163676CLS200/300 Spare aluminum lid with window
A5E01163677Kit, sensor for cable units, PPS, standard, Viton
A5E01163678Kit, sensor for cable units, PPS, digital, Viton
A5E01163679Kit, sensor for cable units, PPS, standard, FFKM
A5E01163680Kit, Sensor for cable units, PPS, Digital, FFKM
A5E01163681Kit, Sensor for cable units, PVDF, Standard, FKM
A5E01163682Kit, sensor for cable unit, PVDF, Digital, FKM
A5E01163683Kit, sensor for cable unit, PVDF, Standard, FFKM
A5E01163684Kit, sensor for cable unit, PVDF, Digital, FFKM
A5E01163685Spare, 316L stainless steel mounting bracket
A5E01163686Spare, PROFIBUS connector, IP65 versions only
A5E03251681Kit, CLS200 standard, transmitter


Benefits
Potted construction protects signal circuit from shock, vibration, humidity, and/or condensation
High chemical resistance
Level detection independent of tank or pipe earth reference
Insensitive to product buildup due to high frequency oscillation
High sensitivity allows installation in a wide range of liquids, solids or slurry applications
Integral LCD display allows for easy menu-driven setup
PROFIBUS PA communication (SIMATIC PDM compatible)


Application
Pointek CLS200 digital version provides an integral LCD display for stand-alone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network.

The power supply is galvanically isolated and accepts a wide range of voltages (12 to 30 V DC). When used with thermal isolator, the stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to 125 °C (257 °F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1.5 or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe. The menu-driven setup allows precise control of the switch point signal damping and alarm functions.

When connected to the PROFIBUS network, advanced diagnostics and set up using SIMATIC PDM are possible.

The CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic (EMC regulations applicable in some regions).

Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas


Configuration

Technical specifications

Pointek CLS200 - Digital


Mode of operation


Measuring principle

Inverse frequency shift capacitive level detection

Input


Measured variable

Change in picoFarad (pF)

Output


Output signal


  • Solid-state output

  • Output

Galvanically isolated

  • Protection

Against reversed polarity (bipolar)

  • Max. switching voltage
  • 30 V (DC)
  • 30 V peak (AC)
  • Max. load current

82 mA

  • Voltage drop

< 1 V, typical at 50 mA

  • Time delay (ON and/or OFF)

Programmable by user (0 ... 100 s)

  • Fail-safe mode

Min. or max.

  • Connection

Removable terminal block

Rated operating conditions1)


Installation conditions


  • Location

Indoor/outdoor

Ambient conditions


  • Ambient temperature

‑40 ... +85 °C (‑40 ... +185 °F)2)

  • Storage temperature

‑40 ... +85 °C (‑40 ... +185 °F)

  • Installation category

II

  • Pollution degree

4

Medium conditions

Liquids, bulk solids, slurries, and interfaces

  • Relative dielectric constant εr

Min. 1.5

  • Process temperature

  • Without thermal isolator

‑40 ... +85 °C (‑40 ... +185 °F)2)

  • With thermal isolator

‑40 ... +125 °C (‑40 ... +257 °F)

  • Process pressure (rod version)

‑1 ... +25 bar g (‑14.6 ... +365 psi g) (nominal)

  • Process pressure (cable version)3)

‑1 ... +10 bar g (‑14.6 ... +150 psi g) (nominal)

  • Process pressure (sliding coupling version)

‑1 ... +10 bar g (‑14.6 ... +150 psi g) (nominal)

Design


Material


  • Enclosure

Epoxy-coated aluminum with gasket

  • Optional thermal isolator

316L stainless steel

Connection

Removable terminal block, max. 2.5 mm²

Degree of protection

IP65/Type 4/NEMA 4 (optional IP68)

Cable inlet

2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry)

Electromagnetic compatibility

To comply with CE EMC regulations (where applicable); the CLS200 should be installed per the instruction manual.

Power supply


Bus voltage

Standard: 12 ... 30 V DC

Intrinsically Safe: 12 ... 24 V DC

Current consumption

12.5 mA

Certificates and approvals


General Purpose

CSA, FM, CE, UKCA, RCM

Dust Ignition Proof

ATEX II 1/2 D Ex ia/tb [ia Da]
IIIC TX Da/Db,
ATEX III 2(1) D Ex ia tb [ia Da]
IIIC TX Db
UKEX II 1/2 D Ex ia/tb [ia Da]
IIIC TX Da/Db,
UKEX III 2(1) D Ex ia tb [ia Da]
IIIC TX Db

Dust Ignition Proof with IS Probe

CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4

Flameproof Enclosure with IS Probe

ATEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb,
ATEX II 2(1) G Ex db ia [ia Ga] IIC TX Gb

UKEX II 1/2 G Ex ia/db [ia Ga] IIC TX Ga/Gb,
UKEX II 2(1) G Ex db ia [ia Ga] IIC TX Gb

Explosion Proof with IS Probe

CSA/FM Class I, Div. 1, Groups A, B, C, D
CSA/FM Class II, Div. 1, Groups E, F, G
CSA/FM Class III T4

Intrinsically Safe4)

ATEX II 1 G Ex ia IIC TX Ga,
ATEX II 1/2 D Ex ia IIIC TX Da/Db,
ATEX II 1 G Ex ia IIC TX Ga,
ATEX II 2 D Ex ia IIIC TX Db,
ATEX II 1 G Ex ia IIC TX Ga,
ATEX II 1 D Ex ia IIIC TX Da,
ATEX II 1/2 D Ex ia IIIC TX Da/Db

UKEX II 1 G Ex ia IIC TX Ga,
UKEX II 1/2 D Ex ia IIIC TX Da/Db,
UKEX II 1 G Ex ia IIC TX Ga,
UKEX II 2 D Ex ia IIIC TX Db,
UKEX II 1 G Ex ia IIC TX Ga,
UKEX II 1 D Ex ia IIIC TX Da,
UKEX II 1/2 D Ex ia IIIC TX Da/Db

Non-incendive

CSA/FM Class I, Div. 2, Groups A, B, C, D
CSA/FM Class II, Div. 2, Groups F, G
CSA/FM Class III T4 or T6

Non-Sparking

ATEX II 3 G Ex ec IIC T6 ... T4
ATEX II 2 D IP6X T100 °C

UKEX II 3 G Ex ec IIC T6 ... T4
UKEX II 2 D IP6x T100°C

Marine

Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5

Others

Pattern Approval (China)

Communication

PROFIBUS PA (IEC 61158 CPF3 CP3/2)
Bus physical layer: IEC 61158-2 MBP (IS)
Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device