Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Passive Components >

3 Core Mineral Insulated Metal Sheathed Cable with Customizable Length (1-5m) and High Temperature Range (200℃-1000℃)

Categories Mineral Insulated Metal Sheathed Cable
Brand Name: LEADKIN
Model Number: LK-K
Certification: ISO9001, IATF16949, CE
Place of Origin: NINGBO CHINA
MOQ: 50M
Price: negotiation
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1,000,000M/year
Delivery Time: 2-7 working days
Packaging Details: 70*70*8cm Carton
Core: 2,3,4,6
Insulation: MgO
Warranty: 1 Year
Temperature Range: 200℃-1000℃
Accuracy: Class I、II、III
Outside Dia: 0.5-12.7mm
Package: Carton. Pallet
Function: temperature test
Cable Length: 1-5m or Customized
Thermocouple Type: K/N/E/J/T/S/R/B
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

3 Core Mineral Insulated Metal Sheathed Cable with Customizable Length (1-5m) and High Temperature Range (200℃-1000℃)

3 Core Mineral Insulated Metal Sheathed Cable With 4.0-8.0mm
Product Specifications
Core2,3,4,6
InsulationMgO
Warranty1 Year
Temperature Range200℃-1000℃
AccuracyClass I, II, III
Outside Dia0.5-12.7mm
PackageCarton, Pallet
FunctionTemperature test
Cable Length1-5m or Customized
Thermocouple TypeK/N/E/J/T/S/R/B
Product Details
Quick Details
Type: K/N/E/J/T/S/R/B
Place of Origin: Zhejiang, China
Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
Core number: 2,3,4,6
Inorganic mineral insulating lead material: Ni, Cu
Insulator: 99.6% high purity MgO
Certificate: ISO9001, IATF16949, CE
Application: Connecting with thermocouple and instrument machine
Sheath material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Type for Sheath Wire Type K
Product NameCodeTypeSheath MaterialOutside Dia.Temperature
NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400




1.5-3.2600




4.0-8.0800



SS310 Inconel6000.5-1.0500




1.5-3.2800




4.0-6.4900




8.0-12.71000
NiCrSi-NiSiNKNSS304 SS3160.5-1.0400




1.5-3.2600




4.0-8.0800



SS310 Inconel6000.5-1.0500




1.5-3.2800




4.0-6.4900




8.0-12.71000
NiCr-KonstantanEKESS304 SS3160.5-1.0400




1.5-3.2600




4.0-8.0800
Fe-KonstantanJKJSS304 SS3160.5-1.0400




1.5-3.2600




4.0-8.0800
Cu-KonstantanTKTSS304 SS3160.5-1.0400




1.5-3.2600




4.0-8.0800
RhPt10-PhSKSInconel6006.0-12.71100
Note: Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples. The data in the table is only recommended data.
Accuracy for Sheath Wire Type K
TypeClass IClass II
K±1.5℃ (-40~375℃)±2.5℃ (-40~375℃)
±0.4% (375℃-1000℃)±0.75% (375℃-1000℃)
N±1.5℃ (-40~375℃)±2.5℃ (-40~375℃)
±0.4% (375℃-1000℃)±0.75% (375℃-1000℃)
E±1.5℃ (-40~375℃)±2.5℃ (-40~375℃)
±0.4% (375℃-800℃)±0.75% (375℃-800℃)
J±1.5℃ (-40~375℃)±2.5℃ (-40~375℃)
±0.4% (375℃-800℃)±0.75% (375℃-800℃)
T±0.5℃ (-40~125℃)±1.0℃ (-40~125℃)
±0.4% (125℃-350℃)±0.75% (125℃-350℃)
S±1.0℃ (0-1100℃)±1.5℃ (0-1100℃)
Product Overview

When discussing a 3-core mineral insulated cable (MIC) of the K type for thermocouples, specifically in the 4.0-8.0 mm range, there are several key aspects to consider:

Overview of K Type Thermocouples:
K Type Thermocouples: These are made from Chromel (Nickel-Chromium alloy) and Alumel (Nickel-Aluminum alloy) and are one of the most common types due to their wide temperature range (-200°C to 1260°C) and good stability.
Thermocouple Functionality: Thermocouples work by measuring the voltage generated at the junction of two different metals, which correlates to temperature.
Features of 3-Core Mineral Insulated Cable:
Construction:

Core: The cable contains three conductors, typically two for the thermocouple (Chromel and Alumel) and a third for a reference or compensation wire.
Insulation: The conductors are insulated with mineral insulating material (often magnesium oxide), which allows for high thermal conductivity and excellent dielectric properties.
Sheathing: Typically, the cable is sheathed in a metal sheath (such as stainless steel), providing mechanical protection and resistance to corrosion and high temperatures.
Diameter:

4.0-8.0 mm: This indicates the outer diameter of the cable. The choice of diameter affects flexibility, installation ease, and the thermal response time of the thermocouple.
Temperature Range:

Mineral insulated cables can withstand high temperatures, making them suitable for industrial applications.
Applications:

Used in harsh environments, such as furnaces, reactors, and other industrial processes where precise temperature measurement is crucial.
Advantages:

Durability: Resistant to moisture, corrosion, and extreme temperatures.
Response Time: Fast response to temperature changes due to the compact nature of the construction.
Accuracy: High accuracy and stability over a wide temperature range.
Considerations for Use:
Ensure compatibility with the measurement system and calibration.
Consider the environment where the thermocouple will be used, including exposure to chemicals or mechanical stress.
Proper handling during installation is necessary to avoid damaging the cable or its insulation.

Advantages
  • Wide temperature range measurement
  • Durable construction for harsh environments
  • Fast response to temperature changes
  • Relatively inexpensive
  • Simple and rugged design
Considerations
  • Regular calibration needed for accuracy
  • Proper installation critical for accurate readings
  • Choose appropriate type based on environmental conditions
  • Non-linear output requires calibration
  • Reference junction compensation needed for precise measurements
Product Images
3 Core Mineral Insulated Metal Sheathed Cable
Company Information
Main Products
Leadkin main products Leadkin product line
Package
We add heat shrink tubing and plastic film to ensure high insulated resistance. Each coil cable includes marking notes, pass card and test report.
Leadkin cable packaging
MI Cable Production Line
We have high-quality professional products with advanced production lines and equipment. All products comply with international quality standards and are appreciated in global markets. We continuously improve our production systems and product quality to meet increasing market demands.
Order Process
  1. Request accurate quotation
  2. Confirm price, trade terms, lead time, and payment terms
  3. Receive Proforma Invoice with company seal
  4. Arrange payment for deposit and send bank slip
  5. Receive production line photos showing your products
  6. Receive mass production photos before completion
  7. Make balance payment and receive shipping details
  8. Confirm satisfactory receipt of goods
  9. Provide feedback on quality and service
Frequently Asked Questions
What are the advantages of using thermocouples?
Wide temperature range, fast response time, simple and rugged design, relatively inexpensive, and can be used in various environments including extreme conditions.
What are the disadvantages of thermocouples?
Non-linear output requiring calibration, potentially lower accuracy than other sensors, requires reference junction compensation, and susceptible to electromagnetic interference.
Quality 3 Core Mineral Insulated Metal Sheathed Cable with Customizable Length (1-5m) and High Temperature Range (200℃-1000℃) for sale
Send your message to this supplier
 
*From:
*To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0