| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Energy Meter Testing Equipment |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC1893R |
| Certification: | ISO, CE |
| Place of Origin: | CHINA |
| MOQ: | 1 Piece |
| Price: | negotiation |
| Payment Terms: | L/C,T/T,D/P |
| Supply Ability: | 10 PCS per month |
| Delivery Time: | 4-8weeks |
| Packaging Details: | Standard Export Carton |
| Voltage: | 3x230 / 400 V ±10%, 50 / 60 Hz ±2 Hz |
| Frequency: | 50 Hz ±15% |
| Power capacity: | > 6 kVA |
| Power efficient(at full load): | ≥85% |
| Ambient temperature: | -10 °C -- +40 °C |
| Relative humidity: | 35% - 85% |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
The YC1893D meter test system consists of:
Three-phase power source for precise voltage and current output
Three-phase reference standard meter for high-accuracy calibration
Meter suspension racks compatible with single-phase and three-phase meters
Smart meter function testing system (optional: fixed voltage, optical probe, relay control test, ripple control box)
PC and software for automated control, data acquisition, and test management
Auxiliary components necessary for complete electricity meter testing
The YC1893D meter test system is fully compliant with international standards:
IEC 60736 – stationary meter test systems
IEC 62052-11 and IEC 62053 series – accuracy classes 0.2, 0.5, 1.0
IEC 62056 – electricity metering data exchange
EN 50470 series – European utility meters
IEC 61010 – electrical safety
These certifications ensure IEC-compliant meter testing for both single-phase and three-phase meters, including smart meters.
Voltage | |
Test voltage output (Phase-Neutral) | 3x(24 – 300 V) |
Power of the voltage output | 3×1000VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load | < 0.01% |
Distortion factor | < 0.3% for linear resistance load |
Harmonics | 2nd – 21st free programmable |
Current | |
Test current output | 1 mA – 120 A |
Power of the current output | 3×2000VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005%/h (integration time 150 s) |
Load regulation from 0-max. load | < 0.01% |
Distortion factor | < 0.3% for linear resistance load |
Harmonics | 2nd – 21st free programmable |
Phase angle | |
Range | 0 -- 360° |
Resolution | 0.01° |
Setting accuracy | 0.1° |
Frequency | |
Range | 45 Hz – 65 Hz |
Resolution | 0.01 Hz |

|