Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Roadway Safety >

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Categories Weight Control indicator
warranty: 1 years
customized support: OEM, ODM, OBM, Software reengineering
place of origin: Guangdong, China
brand name: SNC China Load cell amplifier transmitter
accuracy: Other
model number: amplifier transmitter
type: Axle Scale
display type: no
Name: 4-20mA amplifier transmitter
Material: plastic housing
Voltage: 24VDC
Output signal: RS485
Working temperature: -20~80 ℃
Precision: more than 0.1%F.S
Display: metal case support
Size: 145/115x80x46mm
load cell connection: 1- 4 load cells
working temp.: -10--70 degree
Price: $80/pieces
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering

Load cell digital amplifier RS485 output

Load Cell Digital Amplifier RS485 Output


Voltage: 10V


Output signal: 0-5V, 0-10V, 4-20mA (Optional)


Working temperature: -20~80


Working environment Humidity: 10%RH-90%RH


Precision: more than 0.1%F.S


China Load cell amplifier transmitter


Load Cell Digital Amplifier RS485 Output



Calibration:


First, with the whole system UNLOADED, adjust "ZERO" potentiometer to adjust the zero offset.


Measure the output voltage or current of signal output with multimeter, make sure the value is as close to


zero as possible. Otherwise zero variation will get bigger when we change gain factor.


1, Gain adjustment


Add known load to the system (recommend: 80%~100% of Full Scale), then calculate value of the


output voltage or current according to the ratio between loaded weight and the maximum capacity.


Get output value using a multimeter. Adjust amplifier gain by turning "FULL SCALE" potentiometer.


2, Review


Unload the system and measure zero output. Make sure that it is as close as possible to zero.


Add known load, check whether the output voltage or current is amplified as needed you wanted or not.


If not, repeat steps 1 and 2.


(Note: this section is for standard sensor amplifier parameters. For special requirements, please


contact our sales department)


Product Description

Sensorcon Product Lists
Strain GaugeLoad CellTorque SensorDisplay
Linear Strain gauge-AAWireless sensorSlip ring rotary torque sensorPlatform scale display
Half bridge strain gauge-BB,HA,GB,FBMicro load cellContactless rotary torque sensorTruck scale display
Shear/torque strain gauge-AB,HASingle point load cellStatic torque sensorController
Full bridge strain gauge-EB, FG,FDButton load cellMetersJunction box
Tee Rosettes strain gauge-CA,BAShear beam load cellCouplingBig screen display
Round type strain gaugeS type load cellAmplifier
Semi-conductor strain gaugeColumn load cell
Bridge type load cell

Company Information

Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.


Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.


Load Cell Digital Amplifier RS485 Output


Related Products

Load Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 Output
Load Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 Output
Load Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 OutputLoad Cell Digital Amplifier RS485 Output

Product List

Sensorcon Product Lists
Strain GaugeLoad CellTorque SensorDisplay
Linear Strain gauge-AAWireless sensorSlip ring rotary torque sensorPlatform scale display
Half bridge strain gauge-BB,HA,GB,FBMicro load cellContactless rotary torque sensorTruck scale display
Shear/torque strain gauge-AB,HASingle point load cellStatic torque sensorController
Full bridge strain gauge-EB, FG,FDButton load cellMetersJunction box
Tee Rosettes strain gauge-CA,BAShear beam load cellCouplingBig screen display
Round type strain gaugeS type load cellAmplifier
Semi-conductor strain gaugeColumn load cell
Bridge type load cell
Buying Guides

Load Cell Digital Amplifier RS485 Output

Quality Load Cell Digital Amplifier with RS485 Output 145/115x80x46mm Size and Customized Support Software Reengineering for sale
Send your message to this supplier
 
*From:
*To: Hunan Jinlian Cloud Information Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0