| Brand Name: | HUATEC |
| Model Number: | HCDX-1500 |
| Certification: | ISO,CE |
| Place of Origin: | China |
| MOQ: | 1set |
| Payment Terms: | L/C,T/T,Western Union |
| Supply Ability: | 100 sets per month |
| Delivery Time: | 8~10 working days after payment |
| Packaging Details: | in wooden box |
| Product name: | Movable Magnetic Particle Flaw Detector |
| AC magnetization current: | AC 0~1500A (effective value) continuously adjustable |
| Output cable: | 2 copper-core flexible cables (120mm2) of 3 meters |
| Power supply: | 220V (two-phase three-wire system) |
| Company Info. |
| HUATEC GROUP CORPORATION |
| Verified Supplier |
| View Contact Details |
| Product List |
AC/HWDC 1500A Movable Magnetic Particle Flaw Detector with Automatic Demagnetizing Function
The HCDX-1500 mobile magnetic particle flaw detector can magnetize parts in AC (or half wave DC magnetization HWDC). And with automatic demagnetization function, no additional demagnetization device is required. 8-bit MCU is adopted as the controller by this magnetic particles flaw detector, and the continuous regulation of magnetizing current can be realized through the precise collection of the AC zero voltage crossing signal and the signal of current regulation. It has the function of maximum current limit. With the function of phase controlled, the detector is suitable for both continuous technique and residual technique.
Technical parameters:
| AC magnetizing current (AC) | 0 ~ 1500A (true RMS) |
| Half wave DC magnetizing current (HWDC) | 0 ~ 1500A (2 times the average) |
| Demagnetization | (AC) 1500 ~ 0A (HWDC) 1500 to 0A |
| Temporary load rate | ≤30% |
| Demagnetization time | < 5s |
| Input voltage | 380V 50Hz |
Main functions:
Detection methods: support rod method, winding method, coil method
Magnetization method: AC magnetization, DC magnetization (HWDC),
pulse magnetization
Demagnetization method: AC demagnetization using far away method
demagnetization (attenuation method), AC demagnetization using
ultra-low frequency demagnetization
Standard configuration:
Mobile host 1
Support rod probe 1 set
robe cable 1
Foot switch 1
Optional accessories:
Fixed coil
Wound cable


|