SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz

Categories Electronic Test And Measurement Equipment
Brand Name: SRS
Model Number: SRS540
Place of Origin: USA
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Supply Ability: in stock
Product name: Optical Chopper Controller
Chopping frequency: 4 Hz to 3.7 kHz
Frequency display: 4-digit, 1 Hz resolution and accuracy
Cable length: 6 ft.
Power: 12 W, 100/120/220/240 VAC, 50/60 Hz
Interfaces: GPIB, RS-232 and Ethernet
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz

SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz


Description of SRS Stanford Research Systems SRS540 Optical Chopper Controller


The SR540 chopper will handle all your optical chopping requirements—from simple measurements to dual-beam and intermodulation experiments. The SR540 has a 4-digit frequency display, front-panel frequency control, analog voltage frequency control and two reference outputs with selectable operating modes


The SR540 chopper will handle all your optical chopping requirements—from simple measurements to dual-beam and intermodulation experiments. The SR540 has a 4-digit frequency display, front-panel frequency control, analog voltage frequency control and two reference outputs with selectable operating modes. Two anodized aluminum blades are provided: a 5/6 slot blade for frequencies up to 400 Hz, and a 25/30 slot blade for frequencies up to 3.7 kHz. Reference outputs are provided for frequencies corresponding to each row of slots, as well as the sum and difference frequencies.


Features of SRS Stanford Research Systems SRS540 Optical Chopper Controller

Optical Chopper Applications


Single-Beam Experiment

In this application, a single optical beam is chopped by the outer row of slots, and the reference output from the right BNC is used to lock the lock-in amplifier to the chop frequency. The inner row of slots could also be used, in which case the left BNC would be the reference output. In either case, the REFERENCE MODE switch is in the “up” position.


Dual-Beam Experiment

In this arrangement, the output from a single source is split and chopped at two different frequencies by the two rows of chopper slots. One beam passes through the experiment while the other is used as a reference beam. The beams are recombined and sent to the same detector. Two lock-ins are used to detect the signals at ƒinner, corresponding to the experimental signal, and ƒouter, corresponding to the reference beam. If the detected signal in the experimental arm is ratioed to the detected signal in the control arm, then effects due to changing source intensity and detector efficiency are removed.


Specification of SRS540


Chop frequency4 Hz to 400 Hz (5/6 slot blade)
400 Hz to 3.7 kHz (25/30 slot blade)
Frequency stability250 ppm/°C (typ.)
Frequency drift<2 %, 100 Hz < f < 3700 Hz
Phase jitter (rms)0.2° (50 Hz to 400 Hz)
0.5° (400 Hz to 3.7 kHz)
Frequency display4-digit, 1 Hz resolution and accuracy
Frequency control10-turn pot with 3 ranges:
4 Hz to 40 Hz
40 Hz to 400 Hz
400 Hz to 3.7 kHz
Input control voltage0 to 10 VDC for 0 to 100% of full scale. Control voltage overrides frequency dial.
Reference modesƒinner, ƒouter, 5 × ƒouter, ƒinner + ƒouter, ƒouter - ƒinner
DimensionsController: 7.7" × 1.8" × 5.1" (WHL)
Chopper head: 2.8" × 2.1" × 1.0" (WHL)
Blade diameter4.04" ±0.002"
Cable length6 ft.
Power12 W, 100/120/220/240 VAC, 50/60 Hz
WarrantyOne year parts and labor on defects in materials and workmanship, 90 days on motor.

Ordering Information for SRS540


SR540 Optical chopper

O5402530 25/30 dual-slot replacement blade

O54056 5/6 dual-slot replacement blade

O5405 5-slot replacement blade

O54030 30-slot replacement blade

O540RCH Replacement chopper head


FAQ:

1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.

2. What delivery method do you use? and delivery time?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question?

You can contact us online or leave us messages below.



Quality SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz for sale
Send your message to this supplier
 
*From:
*To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0