| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Inverter Aging Test Equipment |
|---|---|
| Brand Name: | CPET |
| Model Number: | CP-NBQ829 |
| Place of Origin: | China |
| MOQ: | 2sets |
| Price: | 8550dollars/set |
| Payment Terms: | L/C |
| Supply Ability: | 30sets/month |
| Delivery Time: | 35 work days |
| Packaging Details: | Wooden case packing |
| Trolley size (mm): | L205*W125*H205cm |
| Warranty: | 1 year |
| Weight: | 400kg |
| Company Info. |
| Shenzhen CPET Electronics Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Burn-In Test Cabinet For Half-Bridge Full-Bridge Bidirectional Inverter
| Burn-in cabinet structure and Burn-in quantity planning | Trolley size (mm) | L2050*W1250*H2050mm (size of a single Burn-in cabinet) |
| Number of trolley layers | 6 layers, product area depth 400mm, (6 Burn-in positions per layer) | |
| Trolley height | 175mm | |
| Trolley structure material | 2.0mm thick cold rolled sheet | |
| Load area cooling method | Top turbine exhaust fan top row type (easy to control the ambient temperature) | |
| Introduction to energy recovery module configuration, power of the tested power supply and Burn-in quant | Energy recovery module control method | RS485 communication mode, upper computer uses RS232 communication mode |
| Product burn-in mode | The burn-in process of the product is carried out by the way of relative drag | |
| Dc power isolation mode | Dc power channel adopts photoelectric isolation (communication and power supply isolation) | |
| Introduction of electric control and temperature control device for power Burn-in cabine | Wiring | Customer specified interface; Input/output port Anderson connector |
| Panel function keys | Input AC voltage display, start switch, emergency stop switch | |
| Trolley power distribution and control mode | 380V three-phase five-wire distribution; Computer monitoring and automatic electric control | |
| Trolley power distribution | A single burn-in cabinet is 3000W*36/0.85≈127KW, and the measured power efficiency is calculated as 85% | |
| Way to control | The electric control includes manual/automatic switching, which is
monitored by the computer in real time | |
| Safety protection | Equipment grounding protection, leakage switch protection, smoke
alarm automatic power-off protection, etc. | |
| Introduction to the main functions of the system | Applicable to energy storage power,current converter, inverter, regurgitator,transverter, medical power supply and so on | |
| Free configuration of self-developed special monitoring software for power Burn-in, with independent intellectual property rights and no legal risks | ||
| Use programmable electronic load module to monitor output terminal voltage, current and power parameters | ||
Dedicated monitoring software for Burn-in enjoys free final upgrade service, powerful expansion function, saving repeated investment in equipment | ||
Burn-in parameters, time setting, ON/OFF sequence editing (test of
the product being tested on and off), support for automatic voltage
switching, load | ||
The function of automatically turning off the power at the end of the Burn-in of the tested power supply is convenient for unattended | ||
The computer automatically displays the quality of the tested power
supply product, and multiple windows in the window are convenient
for centralized | ||
The computer can store the Burn-in data report of the tested power supply, the process parameters of the tested power supply are easy to trace | ||
|