| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Flammability Testing Equipment |
|---|---|
| Brand Name: | Haida |
| Model Number: | 6007-HD |
| Certification: | CE,,ISO |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Negotiation |
| Payment Terms: | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
| Supply Ability: | 300 Sets per Month |
| Delivery Time: | 20 days after order confirmed |
| Packaging Details: | each set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
| Test Channels: | 5 independent test groups |
| Voltage Stability: | ±1% |
| Test Voltage Range: | 100V-6000V (continuously adjustable) |
| Output Voltage Mode: | AC/DC (switchable) |
| Voltage Regulator: | Output: 0-250V adjustable; Capacity: 5kVA |
| Test Duration: | 6 hours |
| Droplet Interval: | Adjustable: 0-99.99 seconds/minutes/hours |
| Chamber Volume: | 900L × 650W × 950H (mm); 0.56 m³ |
| Power Supply: | AC 220V,50Hz,1KVA |
| Company Info. |
| Hai Da Labtester |
| Verified Supplier |
| View Contact Details |
| Product List |
This instrument is designed to evaluate the tracking and erosion
resistance of electrical/electronic products, household appliances,
and their materials. It simulates severe environmental conditions
by applying liquid contaminants and inclined samples under power
frequency (45Hz-65Hz) to assess the tracking and erosion resistance
grades of electrical insulation materials.
| Model | 6007-HD |
| Test Channels | 5 independent test groups. |
| Voltage Stability | ±1% |
| Test Voltage Range | 100V-6000V (continuously adjustable) |
| Output Voltage Mode | AC/DC (switchable) |
| Voltage Regulator | Output: 0-250V adjustable; Capacity: 5kVA |
| Test Transformer | Capacity: 5kVA; Max. output voltage: AC 6000V |
| High-Precision Stabilizer | Output: AC 220V; Power: 6000W; Accuracy: ±1% |
| Electrodes | Material: 304 stainless steel, thickness: 0.5mm; Electrode spacing: 50.0mm ±0.1mm |
| Overcurrent Protection | Trips at ≥60mA for 2 seconds, triggering an audible alarm (reset via voltage stop). |
| Tracking Criteria | Per GB/T 6553-2014 Clause 4.1.2: Voltage applied (2.5kV/3.5kV/4.5kV) with contaminant flow; current must remain below 60mA for 6 hours to pass. |
| Test Duration | 6 hours. |
| Droplet Interval | Adjustable: 0-99.99 seconds/minutes/hours |
| Droplet System | High-precision peristaltic pump (LEAF); Flow rate: 0.00185-20 mL/min; Speed: 0.1-50 rpm; Accuracy: <0.5%. |
| Test Solution | Mixture of ammonium chloride, isooctylphenoxy polyethoxy ethanol (nonionic wetting agent), and deionized water. Resistivity: (3.95 ±0.05) Ω·m at (23±1)°C |
| Filter Paper | Standard dimensions; Thickness: 0.15-0.17mm |
| Chassis Material | SUS304 stainless steel (brushed finish) |
| Contaminant Tank | 316 stainless steel with sealed design. |
| Chamber Volume | 900L × 650W × 950H (mm); 0.56 m³ |
| Overall Dimensions | 1300L × 700W × 1800H (mm) |
| Control System | PLC + touchscreen; Automated report generation; Built-in thermal printer for real-time results. |
| Design Features | Integrated structure with control panel on the right |
| Glass-view door for observation | |
| Top-mounted exhaust fan for fume extraction post-test |




Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training-
Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined
FAQ
Q: How about your warranty?
Q: What is the order process?
Q: Can we visit your factory before order?
Q: Do you accept customization service?
|
|