Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Pumps & Parts >

Opering Pressure 4-5 Bar MPV Minimum Pressure Control Valve For Medium Temp. -20C- 120C Applications

Categories Pneumatic Solenoid Valve
Brand Name: NBSANMINSE
Model Number: MPV-40A
Certification: ISO9001
Place of Origin: CHINA
MOQ: 10PCS
Price: Negotiate
Payment Terms: L/C,T/T
Supply Ability: 1000PCS
Delivery Time: 5-30days
Packaging Details: Box
Orifice: 40mm
Opering Pressure: 4~5 Bar
Maximum Pressure: 15 Bar
 Medium Temp.: -20℃~+120℃
Environment Temp.: -20℃~+60℃
Warranty: 1 Year
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Opering Pressure 4-5 Bar MPV Minimum Pressure Control Valve For Medium Temp. -20C- 120C Applications

inimum pressure valve has the functions of opening/closing,pressure maintaining and backstopping,and offers stable and reliable performance.

MPV Minimum Pressure Control Valve

Model:MPV-40A

Orifice:40mm

Opering Pressure:4~5 Bar

Maximum Pressure:15 Bar

Working Medium Temperature:-20~+120

Working Environment Temperature:-20~+60



Installation Parameters


A Minimum Pressure Valve (MPV) is a pressure-regulating valve that maintains a minimum pressure in a system, often used in rotary screw air compressors to ensure proper lubrication and protect the air-oil separator. At startup, the MPV is closed to allow pressure to build; once a preset minimum is reached, it opens to allow airflow while its built-in check valve prevents backflow at shutdown, ensuring consistent system operation and longevity.
How it Works
Startup: When the compressor starts, the valve is closed, allowing pressure to build within the air-oil separator.
Opening: As system pressure increases, it overcomes the spring force in the valve, causing it to open.
Full Flow: At normal operating pressure, the valve opens fully, allowing the compressor's output to pass through with minimal pressure loss.
Shutdown: If the system pressure drops below the preset minimum, the valve closes.
Check Valve Function: A separate, integrated check valve then closes to prevent air from flowing backward into the compressor during shutdown.
Key Functions
Oil Lubrication:
The MPV establishes a minimum pressure required for lubricating oil circulation in the compressor.
Component Protection:
It prevents compressor damage and ensures the air-oil separator functions correctly by avoiding excessively low pressure.
Smooth Operation:
By maintaining a stable pressure, the MPV prevents issues like cavitation and contributes to the smooth operation of hydraulic and air systems.
Symptoms of a Faulty MPV
Low oil pressure or low temperatures.
Odd compressor noises.
System instability or inefficienc

Quality Opering Pressure 4-5 Bar MPV Minimum Pressure Control Valve For Medium Temp. -20C- 120C Applications for sale
Send your message to this supplier
 
*From:
*To: Ningbo Sanmin Import And Export Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0