| Brand Name: | KACISE | 
| Model Number: | KTG141 | 
| Certification: | CE | 
| Place of Origin: | CHINA | 
| MOQ: | 1PCS | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1000 Piece/Pieces per Week negotiable | 
| Delivery Time: | 5-8 work days | 
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available | 
| Maximum allowable error: | ±1.5% FS. | 
| Sample gas flow rate: | (400 ± 20) mL/min. | 
| Response time: | τ90 ≤ 20S (when the gas passes directly through the gas chamber). | 
| Sample gas pressure: | 0.05MPa ≤ inlet pressure ≤ 0.25MPa. | 
| Output signal: | Optional (4 - 20) mA or (0 - 10) mA. | 
| Contact capacity: | 220V AC, 1A; 24V DC, 2A. | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
The KTG141 Explosion - proof Infrared Gas Analyzer is used for the analysis of inflammable and explosive gases.
Introduction
The KTG141 Explosion - proof Infrared Gas Analyzer adopts imported non - dispersive infrared sensors and advanced digital processing technology to achieve continuous, automatic, rapid and online detection of various gases such as CO, CO₂, CH₄, NH₃ and C₆H₁₄. Compared with similar products, the most prominent features of this product are high stability, high reliability and high selectivity.
Application Areas
The KTG141 has a flame - proof explosion - proof structure and can be widely and safely applied in oil refining, chemical industry, natural gas and other occasions where there are inflammable and explosive gases.
Instrument Features
Technical Parameters
Measuring range:
| Measured Gas | Minimum Range | Maximum Range% | 
| CO | (0 - 100)×10⁻⁶ | (0 - 100)% | 
| CO₂ | (0 - 20)×10⁻⁶ | (0 - 100)% | 
| NH₃ | (0 - 500)×10⁻⁶ | (0 - 100)% | 
| CH₄ | (0 - 100)×10⁻⁶ | (0 - 100)% | 
Maximum allowable error: ±1.5% FS.
Stability: Zero - point drift: ±1% FS/7d; Span drift: ±1% FS/7d.
Sample gas flow rate: (400 ± 20) mL/min.
Response time: τ90 ≤ 20S (when the gas passes directly through the gas chamber).
Sample gas pressure: 0.05MPa ≤ inlet pressure ≤ 0.25MPa.
Output signal: Optional (4 - 20) mA or (0 - 10) mA.
Contact capacity: 220V AC, 1A; 24V DC, 2A.
Working power supply: (220 ± 22) V AC, (50 ± 5) Hz.
Working environment: Temperature: - 10℃ - + 45℃; Humidity: ≤90% RH.
Explosion - proof grade: ExdII CT6.
|   | 
 Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus Output
                                                                                    
                        
                        
                        
                                                            Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus Output
                                                    
                        
                     KFK - G60 - TSP Factory Dust Surveillance Pro
                                                                                    
                        
                        
                        
                                                            KFK - G60 - TSP Factory Dust Surveillance Pro
                                                    
                        
                     R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared Detection And IP54 Protection
                                                                                    
                        
                        
                        
                                                            R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared Detection And IP54 Protection
                                                    
                        
                     KFK - G60 Flammable Gas Sentinel
                                                                                    
                        
                        
                        
                                                            KFK - G60 Flammable Gas Sentinel
                                                    
                        
                     Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                                                    
                        
                        
                        
                                                            Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                    
                        
                     Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V±15% Voltage
                                                                                    
                        
                        
                        
                                                            Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V±15% Voltage
                                                    
                        
                     KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50% 0.3μm and 100% ≥0.5μm
                                                                                    
                        
                        
                        
                                                            KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50% 0.3μm and 100% ≥0.5μm
                                                    
                        
                     KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection Response
                                                                                    
                        
                        
                        
                                                            KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection Response
                                                    
                        
                     Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection Range 0 1
                                                                                    
                        
                        
                        
                                                            Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection Range 0 1
                                                    
                        
                     Professional Electrical Fire Monitoring System For Comprehensive Monitoring
                                                                                    
                        
                        
                        
                                                            Professional Electrical Fire Monitoring System For Comprehensive Monitoring