Operating Principle: Partial pressure electrochemical
Output: 9 mV to 13 mV in 210 mBar O2
Measurement Range: 0 mBar to 1500 mBar O2
Response Time (T90): <15 s (air to 100% O2)
Baseline Offset: <200 μV
Linearity: Linear 0% to 100% O2 (See Note1)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin


MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin


Features:

  • Wide measurement range: It can measure oxygen partial pressure from 0 mbar to 1500 mbar, corresponding to an oxygen concentration range of 0% - 100% vol. O2.
  • Fast response: The response time (t90) is less than 15 seconds (from air to 100% O2).
  • Good linearity: It has a linear output from 0% to 100% O2, which meets the requirements of ISO 80601 - 2 - 55.
  • Stable baseline: The baseline offset is less than 200 μV.
  • Temperature compensation: The temperature compensation is less than 2% O2 equivalent in the range of 0 °C to 40 °C.
  • Wide operating temperature range: It can work in the temperature range of -20 °C to +50 °C.
  • Wide operating pressure range: The operating pressure range is 0.5 bar to 2.0 bar.
  • High - humidity resistance: It can operate in an environment with a humidity range of 0% to 99% rh (non - condensing).
  • Low long - term output drift: In 100% O2, the long - term output drift is less than 5% signal loss per year.

Uses:

The MOX1 oxygen sensor is designed to monitor the partial pressure of oxygen in anesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.


Output9 mv to 13 mv in 210 mbar O2
Measurement Range0 mbar to 1500 mbar O2
Response Time (t90)< 15 s (air to 100% O2)
Baseline Offset< 200 μV
Temperature Compensation< 2% O2 equivalent (0 °C to 40 °C)
External Load Resistor10 kΩ minimum
Connector3 - pin Molex header (Molex 22 - 29 - 2031)
Housing MaterialWhite ABS
Weight39 g (nominal)
Operating Temperature Range- 20 °C to + 50 °C
Operating Pressure Range0.5 bar to 2.0 bar
Operating Humidity Range0% to 99% rh (non - condensing)
Long - term Output Drift in 100% O2< 5% signal loss/year
Recommended Storage Temperature- 10 °C to + 40 °C