| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Walk-in Environmental Test Chamber | 
|---|---|
| Brand Name: | Envsin | 
| Model Number: | ETZ36S | 
| Certification: | CE and ISO | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | To Be Negotiated | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 25 per month | 
| Delivery Time: | 30-35 business days after received the payment | 
| Packaging Details: | Wooden packing | 
| Product name: | Walk In Test Chamber | 
| Key word: | Medicine Testing Machine | 
| Test Space: | 12.5m3 | 
| Internal size: | 2500×2000×2500mm (W×D×H) | 
| External size: | 3900mmx2450mmx2900mm (W×D×H) | 
| Power supply: | AC380V±10%,50Hz±1,60A, 3/N/PE, earth resistance < 4Ω | 
| Max. Power: | 60KW | 
| Max. Currency: | 120A | 
| Company Info. | 
| Envsin Instrument Equipment Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
High Stability Customer Customization Walk In Test Chamber Medicine Testing Machine
The Walk in test chamber is suitable for large size or a large number of machine products, parts, materials for high temperature, low temperature, high low temperature cycle test, and humid heat test. It is mainly used to simulate the product under the combined conditions of climate temperature and humidity or under the changing conditions of ambient temperature and humidity to detect whether the adaptation ability and characteristics of the product change.
The walk in test chamber can be used for the heat dissipation test sample and non-heat dissipation test sample test. For the test of heat dissipation test sample, the heat dissipation power can not exceed the cooling capacity of the refrigeration system of the test box, because the control of temperature and humidity is a dynamic balance process, in different temperature and humidity points, the cooling capacity of the refrigeration system is also accompanied by changes.
Specifications:
| Temp Test 
 | Temp Humidity Test 
 | 
Load Thermal Capacity Chart:
Apply to standard temperature test, the thermal capacity for loading varies from different temperature value.

Temperature and Humidity Control Chart:
Apply to Temp.&. Humid test, the load thermal should not more than 150W

Test Standard:
| 
 | 
 | 
Structure Mode:
Unitary.Test room is on the top, refrigerator is in the bottom; Power distribution control in the back; Main control panel in the front door, and the extended one is on the right-back side. Door opens from right to left. Air circulation channel and air conditioning system are at the back of test space:(centrifugal fan blade,air flow guiding device,heater,humidifier,Refrigeration heat exchanger,Temp and humidity sensing device.
Composition:
Exterior material: Both sides static coated cold rolled steel
Interior material: SUS304 Stainless steel
Insulation material: Rigid polyurethane foam insulation layer

|   | 
 Textiles and Materials Large Testing Space Industrial Walk-In Testing Equipment
                                                                                    
                        
                        
                        
                                                            Textiles and Materials Large Testing Space Industrial Walk-In Testing Equipment
                                                    
                        
                     IEC 60068-2-1 Walk-in Temperature Humidity Chamber for Large-Scale Environmental Testing
                                                                                    
                        
                        
                        
                                                            IEC 60068-2-1 Walk-in Temperature Humidity Chamber for Large-Scale Environmental Testing
                                                    
                        
                     IEC 60068-2-2 Dry Heat Test Walk-in Temperature and Humidity Chamber for Product Reliability Testing
                                                                                    
                        
                        
                        
                                                            IEC 60068-2-2 Dry Heat Test Walk-in Temperature and Humidity Chamber for Product Reliability Testing
                                                    
                        
                     -40℃~100℃ Walk-in Temperature and Humidity Environmental Chambers
                                                                                    
                        
                        
                        
                                                            -40℃~100℃ Walk-in Temperature and Humidity Environmental Chambers
                                                    
                        
                     Large Testing Space Temperature Control Stability Test Chamber with Humidity Control
                                                                                    
                        
                        
                        
                                                            Large Testing Space Temperature Control Stability Test Chamber with Humidity Control
                                                    
                        
                     IEC 60068-2-30 Standard Walk-in Test Chamber for Temperature, Humidity, and Altitude Simulation
                                                                                    
                        
                        
                        
                                                            IEC 60068-2-30 Standard Walk-in Test Chamber for Temperature, Humidity, and Altitude Simulation
                                                    
                        
                     High-Low Industrial Walk-In Testing Equipment Aerospace Component Environmental Test Room
                                                                                    
                        
                        
                        
                                                            High-Low Industrial Walk-In Testing Equipment Aerospace Component Environmental Test Room
                                                    
                        
                     Walk-in Chamber for Extreme Temperature and Humidity Control
                                                                                    
                        
                        
                        
                                                            Walk-in Chamber for Extreme Temperature and Humidity Control
                                                    
                        
                     China Factory High-Volume Walk-in Temperature Humidity Chamber for Product Testing
                                                                                    
                        
                        
                        
                                                            China Factory High-Volume Walk-in Temperature Humidity Chamber for Product Testing
                                                    
                        
                     Walk-In Temperature and Humidity Test Chamber -40℃~150℃ for Automotive Parts Electronics
                                                                                    
                        
                        
                        
                                                            Walk-In Temperature and Humidity Test Chamber -40℃~150℃ for Automotive Parts Electronics