Capacitor Discharge Tester

Description
For IEC Testing of residual voltage after plug disconnect.
The KP-1060 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results.
Scope output for viewing decay waveform.
Presets for IEC 61010-1, IEC62368-1, IEC 60601-1 and IEC60335-1.
Features
Accurate; in accordance with CTL voltage and time specifications.
Disconnects input test voltage at positive or negative peak, normal and reversed polarity
Tests Line-Ground, Line-Neutral and Neutral-Ground.
Micro-controller Technology, one button test, easy setup, LCD display indicates test results.
Ergonomically designed for safety, speed and efficiency.
Designed for product development, production and laboratory use.
Rugged construction that can withstand a 6″ drop with no damage.
Cables, manual and calibration certificate included.
One year warranty.
Technical Parameters:
| Minimum/Maximum Test Voltage | 0-300V | 
| Maximum Test Current | 10A | 
| Fuse: | 10A, 250V, time delay, 1-¼” x ¼” | 
| Probe Impedance | > 100MΩ, < 25pF | 
| AC Peak Detection Accuracy | EUT disconnect within 5% of supply voltage peak | 
| Test Time Range | 0.50 – 99.0 Seconds | 
| Test Time Accuracy | ±1% for times ≥ 1 second, +/- 10ms for < 1 second. | 
| Voltage Setting Resolution | 0.1V | 
| Voltage Meter Accuracy | ±1.5% of instrument measuring range | 
| Frequency | 50-60Hz. | 
| Rated Input Voltage | 220V 50/60HZ | 
|   | 
 IEC 62368-1 Annex E Pink Noise Generator,Meets The Requirements For Pink Noise In IEC 60065 Clause 4.2 And 4.3
                                                                                    
                        
                        
                        
                                                            IEC 62368-1 Annex E Pink Noise Generator,Meets The Requirements For Pink Noise In IEC 60065 Clause 4.2 And 4.3
                                                    
                        
                     ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
                                                                                    
                        
                        
                        
                                                            ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
                                                    
                        
                     ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And Respiratory Equipment
                                                                                    
                        
                        
                        
                                                            ISO5356-1 Figure A.1 22mm Plug And Ring Test Gauges For Testing Anaesthetic And Respiratory Equipment
                                                    
                        
                     ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
                                                                                    
                        
                        
                        
                                                            ISO 80369-7 Fig C.4 Male Luer Reference Connector Hardness Steel Material
                                                    
                        
                     ISO80369-7 Figure C.4 Male Reference Luer Lock Connector For Testing Female Luer Connectors Leakage
                                                                                        
                                                        
                        
                        
                        
                                                            ISO80369-7 Figure C.4 Male Reference Luer Lock Connector For Testing Female Luer Connectors Leakage
                                                    
                        
                     Male Reference Luer Slip Connector For Testing , Female Luer Connectors For Leakage/iso80369 gauges/iso594 gauge
                                                                                    
                        
                        
                        
                                                            Male Reference Luer Slip Connector For Testing , Female Luer Connectors For Leakage/iso80369 gauges/iso594 gauge
                                                    
                        
                     ISO 9360-1 Heat And Moisture Exchangers (HMEs) For Humidifying Respired Gases In Humans-Measurement Of Moisture Loss
                                                                                        
                                                        
                        
                        
                        
                                                            ISO 9360-1 Heat And Moisture Exchangers (HMEs) For Humidifying Respired Gases In Humans-Measurement Of Moisture Loss
                                                    
                        
                     Mask Virus Filtration Efficiency VFE Detector With High Brightness Color Touch Screen
                                                                                    
                        
                        
                        
                                                            Mask Virus Filtration Efficiency VFE Detector With High Brightness Color Touch Screen
                                                    
                        
                     ISO5356-1 Figure A.1 15mm Hardness Steel Plug Gauge / Plug And Ring Test Gauges For Cones And Sockets
                                                                                    
                        
                        
                        
                                                            ISO5356-1 Figure A.1 15mm Hardness Steel Plug Gauge / Plug And Ring Test Gauges For Cones And Sockets
                                                    
                        
                     50Hz Electrical Safety Test Equipment Respirator Resistance Detector
                                                                                    
                        
                        
                        
                                                            50Hz Electrical Safety Test Equipment Respirator Resistance Detector