| Sign In | Join Free | My entremaqueros.com |
|
| Categories | IFM Pressure Sensor |
|---|---|
| Brand Name: | IFM |
| Model Number: | O1D100 |
| Certification: | 3C |
| Place of Origin: | GERMANY |
| MOQ: | 1 |
| Price: | $513/piece |
| Payment Terms: | T/T |
| Supply Ability: | 1piece in stock |
| Delivery Time: | 3 day |
| Packaging Details: | 65*55*55mm |
| Weight[g]: | 243.5 |
| Dimensions[mm]: | 59 x 42 x 52 |
| Company Info. |
| Xiamen ZhiCheng Automation Technology Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
| Product characteristics | |||||||||||
| Laser protection class | 2 | ||||||||||
| Housing | rectangular | ||||||||||
| Electrical data | |||||||||||
| Operating voltage | [V] | 18...30 DC; ("supply class 2" tocULus) | |||||||||
| Current consumption | [mA] | < 150 | |||||||||
| Protection class | III | ||||||||||
| Reverse polarity protection | yes | ||||||||||
| Typ. lifetime | [h] | 50000 | |||||||||
| Inputs / outputs | |||||||||||
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
| Outputs | |||||||||||
| Total number of outputs | 2 | ||||||||||
| Electrical design | PNP | ||||||||||
| Number of digital outputs | 2 | ||||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||||
| Max. current load per output [mA] | 200 | ||||||||||
| Number of analogue outputs | 1 | ||||||||||
| O1D100 | |||||||||||
| Photoelectric distance sensor | |||||||||||
| O1DLF3KG/IO-LINK | |||||||||||
| Analogue current output | [mA] | 4...20; (IEC 61131-2) | |||||||||
| Max. load | [Ω] | 250 | |||||||||
| Analogue voltage output | [V] | 0...10; (IEC 61131-2) | |||||||||
| Min. load resistance | [Ω] | 5000 | |||||||||
| Short-circuit protection | yes | ||||||||||
| Type of short-circuit protection | pulsed | ||||||||||
| Overload protection | yes | ||||||||||
| Detection zone | |||||||||||
| Max. light spot width | [mm] | 15 | |||||||||
| Max. light spot height [mm] | 15 | ||||||||||
| Light spot dimensions refer to | 10 m | ||||||||||
| Background suppression [m] | 0...19 | ||||||||||
| Measuring/setting range | |||||||||||
| Measuring range | [m] | 0.2...10; (white paper 200 x 200 mm 90% remission) | |||||||||
| Sampling rate [Hz] | 1...50 | ||||||||||
| Interfaces | |||||||||||
| Communication interface | IO-Link | ||||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||||
| IO-Link revision | 1.1 | ||||||||||
| SDCI standard | IEC 61131-9 | ||||||||||
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis | ||||||||||
| SIO mode | yes | ||||||||||
| Required master port type | A | ||||||||||
| Process data analogue | 2 | ||||||||||
| Process data binary | 3 | ||||||||||
| Min. process cycle time [ms] | 6 | ||||||||||
| Supported DeviceIDs | Type of operation | DeviceID | |||||||||
| Default | 806 | ||||||||||
| Operating conditions | |||||||||||
| Ambient temperature [°C] | -10...60 | ||||||||||
| Protection | IP 67 | ||||||||||
| Tests / approvals | |||||||||||
| EMC | EN 60947-5-2 | ||||||||||
| Laser protection class | 2 | ||||||||||
| O1D100 | |||||||||||
| Photoelectric distance sensor | |||||||||||
| O1DLF3KG/IO-LINK | |||||||||||
| Notes on laser protection | Caution: | laser light | |||||||||
| Power: | <= 4 mW | ||||||||||
| Wave length: | 650 nm | ||||||||||
| pulse: | 1,3 ns | ||||||||||
| Do not stare into beam. | |||||||||||
| Avoid exposure to the laser light. | |||||||||||
| laser class: | 2 | ||||||||||
| EN / IEC60825-1:2007 | |||||||||||
| EN / IEC60825-1:2014 | |||||||||||
| Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. | |||||||||||
| MTTF [years] | 182 | ||||||||||
| Mechanical data | |||||||||||
| Weight [g] | 243.5 | ||||||||||
| Housing | rectangular | ||||||||||
| Dimensions [mm] | 59 x 42 x 52 | ||||||||||
| Materials housing: diecast zinc; front pane: glass; LED window: PC Lens alignment side lens | |||||||||||
| Displays / operating elements | |||||||||||
| Display | switching status | 2 x LED, yellow | |||||||||
| operation | LED, green | ||||||||||
| distance value, programming | alphanumeric display, 4-digit | ||||||||||
| Accessories | |||||||||||
| Remarks | |||||||||||
| Remarks | For more information about the measuring range / application please refer to the operating instructions. | ||||||||||
| Pack quantity | 1 pcs. | ||||||||||
| Electrical connection | |||||||||||
| Connector: 1 x M12; coding: A | |||||||||||
![]() | |||||||||||
| O1D100 | |||||||||||
| Photoelectric distance sensor | |||||||||||
| O1DLF3KG/IO-LINK | |||||||||||
| Connection | |||||||||||
![]() | |||||||||||
| 2: OUT2 switching output or 4...20 mA / 0...10 V | |||||||||||
| 4: OUT1 switching output or IO-Link | |||||||||||
| 5: IN Laser On/ Off | |||||||||||
| Other data | |||||||||||
| Parameter | Setting range | Factory setting | |||||||||
| Uni | mm, m, inch | mm | |||||||||
| OU1 | Hno, Hnc, Fno, Fnc | Hno | |||||||||
| SP1 [mm] | 200...9999 | 1000 | |||||||||
| nSP1 [mm] | 200...9999 | 800 | |||||||||
| FSP1 [mm] | 200...9999 | 1200 | |||||||||
| OU2 | Hno, Hnc, Fno, Fnc, I, U | I | |||||||||
| SP2 [mm] | 200...9999 | 2000 | |||||||||
| nSP2 [mm] | 200...9999 | 1800 | |||||||||
| FSP2 [mm] | 200...9999 | 2200 | |||||||||
| ASP [mm] | 0...9999 | 0 | |||||||||
| AEP [mm] | 0...9999 | 9999 | |||||||||
| rATE [Hz] | 1...50 | 50 | |||||||||
| dS1 [s] | 0...0.1...5 | 0 | |||||||||
| dr1 [s] | 0...0.1...5 | 0 | |||||||||
| dS2 [s] | 0...0.1...5 | 0 | |||||||||
| dr2 [s] | 0...0.1...5 | 0 | |||||||||
| dFo [s] | 0...0.1...5 | 0 | |||||||||
| dIS | d1...3 ; rd1...3; OFF | d3 | |||||||||
| O1D100 | |||||||||||
| Photoelectric distance sensor | |||||||||||
| O1DLF3KG/IO-LINK | |||||||||||
| repeatability/accuracy | |||||||||||
| read/write distance (mm) | repeatability of the measured values white (90 % remission) ± 5.0 mm ± 5.5 mm ± 17.5 mm ± 27.5 mm ± 60.0 mm | accuracy white (90 % remission) ± 15.0 mm ± 15.0 mm ± 25.0 mm ± 35.0 mm ± 70.0mm | |||||||||
| grey (18 % remission) | grey (18 % remission) | ||||||||||
| 200...1000 mm | ±7.5 mm | ± 18.0 mm | |||||||||
| 1000...2000 mm | ±10.0 mm | ± 20.0 mm | |||||||||
| 2000...4000 mm | ±22.5 mm | ± 32.0 mm | |||||||||
| 4000...6000 mm | ±40.0 mm | ± 50.0 mm | |||||||||
| 6000...10000 mm | |||||||||||
| Sampling rate Extraneous light on the object | 50 Hz < 40 klx | ||||||||||
| repeatability/accuracy | |||||||||||
| read/write distance (mm) | repeatability of the measured values white (90 % remission) ± 16.5 mm ± 16.5 mm ± 30.0 mm ± 37.0 mm ± 75.0 mm | accuracy white (90 % remission) ± 26.5 mm ± 26.5 mm ± 40.0 mm ± 47.0 mm ± 85.0mm | |||||||||
| grey (18 % remission) | grey (18 % remission) | ||||||||||
| 200...1000 mm | ±16.5 mm | ± 26.5 mm | |||||||||
| 1000...2000 mm | ±16.5 mm | ± 26.5 mm | |||||||||
| 2000...4000 mm | ±37.0 mm | ± 47.0 mm | |||||||||
| 4000...6000 mm | ±57.0 mm | ± 67.0 mm | |||||||||
| 6000...10000 mm | — | — | |||||||||
| Sampling rate Extraneous light on the object | 50 Hz 40...100 klx | ||||||||||
| repeatability/accuracy | |||||||||||
| read/write distance (mm) | repeatability of the measured values white (90 % remission) ± 4.0 mm ± 4.5 mm ± 13.5 mm ± 19.0 mm ± 37.0 mm | accuracy white (90 % remission) ± 14.0 mm ± 14.5 mm ± 23.5 mm ± 29.0 mm ± 47.0mm | |||||||||
| grey (18 % remission) | grey (18 % remission) | ||||||||||
| 200...1000 mm | ±4.5 mm | ± 15.0 mm | |||||||||
| 1000...2000 mm | ±6.0 mm | ± 16.0 mm | |||||||||
| 2000...4000 mm | ±14.5 mm | ± 24.0 mm | |||||||||
| 4000...6000 mm | ±21.0 mm | ± 31.0 mm | |||||||||
| 6000...10000 mm | – | – | |||||||||
| Sampling rate Extraneous light on the object | 1 Hz < 40 klx | ||||||||||
| O1D100 | |||||||||||
| Photoelectric distance sensor | |||||||||||
| O1DLF3KG/IO-LINK | |||||||||||
| repeatability/accuracy | |||||||||||
| read/write distance (mm) | repeatability of the measured values white (90 % remission) ± 10.0 mm ± 10.0 mm ± 17.0 mm ± 22.0 mm ± 37.0 mm | accuracy white (90 % remission) ± 20.0 mm ± 20.0 mm ± 27.0 mm ± 32.0 mm ± 47.0mm | |||||||||
| grey (18 % remission) | grey (18 % remission) | ||||||||||
| 200...1000 mm | ± 10.0 mm | ± 20.0 mm | |||||||||
| 1000...2000 mm | ± 10.0 mm | ± 20.0 mm | |||||||||
| 2000...4000 mm | ± 18.0 mm | ± 28.0 mm | |||||||||
| 4000...6000 mm | ± 25.0 mm | ± 35.0 mm | |||||||||
| 6000...10000 mm | – | – | |||||||||
| Sampling rate Extraneous light on the object - Range on black object (6 % remission) - The values apply at constant ambient conditions minimum power-on time in minutes | 1 Hz < 40...100 klx - <= 4000 mm - 23 °C / 960 hPa 10 | ||||||||||
|