19-inch Modular Design Data Center Cold / Hot Aisle Containment

Categories Micro Modular Data Center
Brand Name: TC
Model Number: CA*
Certification: GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Place of Origin: China
MOQ: Negotiable
Price: Negotiable
Payment Terms: L/C, T/T, Western Union, MoneyGram
Range of Altitude: 0-2000m
Operating Temperature Range: -10℃ to 45℃
Operating Humidity Range: 5% to 85%
Electrostatic Protection: In accordance with GB50611
Power Supply and Distribution: In accordance with GB50052, GB50054
Lightning Protection: In accordance with GB50343
Air Conditioning: In accordance with GB50019, GB50243
Fire Extinction: In accordance with GB50263
19-inch Cabinet: In accordance with GB3047.2, IEC297-2, DIN41491 PART1, DIN41494 PART7, ANSI/EIARS-310-D; compatible with ETSI
Application Standards: GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Company Info.
TC Smart Systems Group
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

19-inch Modular Design Data Center Cold / Hot Aisle Containment

19-inch Modular Design Data Center Cold / Hot Aisle Containment


Product Application
Data center cabinets are facing a lot of challenges: higher heat density, greater electric energy consumption, lack of space, and cabinet layout not keeping up with the needs of business growth. There has always been increasingly requirements for cooling, though air conditioners are frequently replaced and added. However, there still exists the partial heat island problem, that is, direct mix of cold and hot air resulting in huge waste of cooling capacity. The equipment on top of the cabinet cannot acquire enough cooling capacity as needed, so the overall PUE value still remains high.
The cold/hot aisle containment system separates the cold inlet air and the hot exhaust air. The cold air is pushed under the raised floor and through the closed cold aisle. As the cold air concentrates in front of the cabinet and cools the equipment, it is heated and eventually dissipated into the hot aisle. The hot exhaust air is then routed back to the outlet of air conditioner.
Product Features
Thanks to the hot aisle and cold aisle, the cabinets are no longer placed in the same direction. The fronts of the racks face each other, which fits for the front-to-back heat dissipation of most IT equipment. In doing this, an unnecessary mix of cold and hot air is thus avoided for improved cooling efficiency.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Specifications
Range of Altitude0-2000 m
Operating Temperature Range-10℃ to 45℃
Operating Humidity Range5% to 85%
Electrostatic ProtectionIn accordance with GB50611
Power Supply and DistributionIn accordance with GB50052, GB50054
Lightning ProtectionIn accordance with GB50343
Air ConditioningIn accordance with GB50019, GB50243
Fire ExtinctionIn accordance with GB50263
19-inch CabinetIn accordance with GB3047.2, IEC297-2, DIN41491 PART1, DIN41494 PART7, ANSI/EIARS-310-D; compatible with ETSI

Aisle Components
·Functional Skylight
Installed in front and rear of the cold aisle, space reserved for hygrometer and thermometer, smoke alarm, surveillance cameras and other equipment
·Fire Fighting Linkage Retractable Skylight
Installed in the middle of the cold aisle, in dual flip structure for a decrease in space utilization on top
·Fully Transparent Fixed Skylight
Installed in the middle of the aisle, with a huge scale of tempered glass, for better light penetrability inside the aisle
·Electric Sliding Door
Installed in front and rear of the aisle, with door access, anti-pinch, exit button, alarm and the screen
·Double Flush Door
Install in front and rear of the aisle, with door access, exit button, alarm and automatically closed door
·Double Manual Sliding Door
Installed in front and rear of the aisle, with door access, alarm and automatically closed door
Quality 19-inch Modular Design Data Center Cold / Hot Aisle Containment for sale