Brand Name: GENY
Model Number: YC99T-3C/5C
Certification: ISO, CE
Place of Origin: China
MOQ: 1
Price: negotiate rates
Payment Terms: T/T, L/C, D/P, T/T
Supply Ability: 5 sets / 1 months
Delivery Time: 6~8weeks
Packaging Details: Plywood cases
Material: Aluminum Alloy
Meter Position: 3
Accuracy: 0.05
AC Voltage Output Range: 57.7V,100V, 220V, 380V
Frequency Output: 45Hz – 70Hz
Storage Environment: -20℃~50℃
Environment Condition: 20℃ ~ 30℃ relative humidity
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities

Portable Meter Test System YC99T-3C/5C for Universities and Related Research Institutions

Description:


It is used in the measurement testing center of the grid companies, measurement department of power supply companies and power plants,
national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises, such as railway and petrochemical. Also, it can be used by the manufacturers of energy meters, includes its production, research and development, testing departments, as well as in universities and related research institutions, specialized laboratories.
The meters user can calibrate including : Single-phase active energy meter, three-phasethree-wire active energy meter, three-phase three-wire composite meter, three-phasefour-wire active energy meter, three-phase four-wire composite meter, three-phasethree-wire sine reactive energy meter, three-phase four-wire sine reactive energy metertwo elements 60°reactive energy meter, two elements 90° reactive energy meter, andthree elements 90° reactive energy meter .

Main functions:


  • It can test various single and three phase electronic and mechanical meters;
  • It can automatically or manually test 1ph or 3ph meters’: basic error, creeping test, starting test, standard deviation and etc., the testing plan can be fixed by customers; . It can execute the influence test includes: voltage influence, frequency influence, harmonic influence, reverse phase sequence influence, unbalance voltage influence test;
  • Support DLTN645 communication protocol, and can execute some tests for multiNfunctions energy meters;
  • More output terminals for more operations: RS232, RS485, extend I/O, Ethernet, USB, wifi and etc.;
  • Output 2~63 harmonics
  • 8 inch touchscreen and friendly operation system;
  • It can test 3 pcs meters max.

Specifications:


Model No.YC99T-3C
Meter Position / Accuracy3 / 0.05
AC Voltage output
Range57.7V,100V, 220V, 380V,660
Adjustment Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion≤0.2% (Non capacitive load)
Max Output load20VA/phase
Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
AC Current output
Range0.05A,0.2A,1A,5A,16.67A,50A
Adjust Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion≤0.2% (Non capacitive load)
Max Output load50VA(50A range)
Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
Power output
Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
Active, Reactive power accuracy±0.05%RG
Phase output
Output adjusting range0 ~ 359.99°
Output adjusting power10°,1°,0.1°,0.01°optional
Resolution0.01.
Measurement accuracy±0.05.
Power factor output
Adjusting range-1~0~+1
Measuring resolution0.0001
Measurement accuracy±0.0005
Frequency output
Adjusting range40Hz – 70Hz
Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional
Resolution0.001Hz
Accuracy±0.002Hz
Harmonic setting
Harmonic order2nd~63rd
Harmonic amplitude0~40%
Harmonic angle0 °~359.00°
Harmonic set error2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2%
Energy error measurement
Active energy basic error limit±0.05%RD(voltage30V~660V,current0.02A~60A,PF≥0.5)
Reactive energy basic error limit±0.1%RD(voltage30V~660V,current0.02A~60A,PF≥0.5)
Standard crystal
Frequency accuracy±0.5ppm (leave factory@25℃)
Frequency stability±0.1ppm,-20℃~+70℃
Energy pulse input
Number of energy pulse input3 channels active, 3 channels reactive
General parameters
Power supplyAC220V±15% or 110V±15%
Frequency50Hz~60Hz
Consumption60VA~1000VA
Environment condition20℃ ~ 30℃,relative humidity≤85%
Storage environment-20℃~50℃
Size & Weight600mm(L)X400mm(W) X266mm(H), 30kg
Model No.YC99T-5C
Meter Position / Accuracy3 / 0.05cl
AC Voltage output
Range57.7V,100V, 220V, 380V
Adjustment Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion≤0.2% (resistance load)
Max Output load20VA/phase
Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
AC Current output
Range0.05A,0.2A,1A,5A,20A,100A
Adjust Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG(optional)
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion≤0.2% (Non capacitive load)
Max Output load100VA(100A range)
Measurement Accuracy±0.05%RG(0.05cl), ±0.1%RG(0.1cl)
Power output
Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
Active, Reactive power accuracy±0.05%RG
Phase output
Output adjusting range0 ~ 359.99°
Output adjusting power10°,1°,0.1°,0.01°optional
Resolution0.01.
Measurement accuracy±0.05.
Power factor output
Adjusting range-1~0~+1
Measuring resolution0.0001
Measurement accuracy±0.0005
Frequency output
Adjusting range45Hz – 70Hz
Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz
Resolution0.001Hz
Accuracy±0.002Hz
Harmonic setting
Harmonic order2nd~63rd
Harmonic amplitude0~40%
Harmonic angle0 °~359.99°
Harmonic set error2nd ~ 31st :≤±0.1%, 32nd~63rd : ≤±0.2%
Energy error measurement
Active energy basic error limit±0.05%RD(voltage30V~380V,current0.02A~120A,PF≥0.5)
Reactive energy basic error limit±0.1%RD(voltage30V~380V,current0.02A~120A,PF≥0.5)
Standard crystal
Frequency accuracy±0.5ppm (leave factory@25℃)
Frequency stability±0.1ppm,-20℃~+70℃
Energy pulse input
Number of energy pulse input3 channels active, 3 channels reactive
General parameters
Power supplyAC220V±15% or 110V%15%
Frequency50Hz~60Hz
Consumption60VA~1000VA
Environment condition20℃ ~ 30℃,relative humidity≤85%
Storage environment-20℃~50℃
Size & Weight600mm(L)X400mm(W) X266mm(H), 48kg
*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Quality 45Hz–70Hz Portable Meter Test Equipment YC99T-3C/5C For Universities for sale
Send your message to this supplier
 
*From:
*To: Guangzhou GENY Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0