| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Stationary Meter Test Equipment |
|---|---|
| Brand Name: | GENY |
| Model Number: | YC1893D |
| Certification: | ISO, CE |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | negotiate rates |
| Payment Terms: | T/T, L/C, D/P, T/T |
| Supply Ability: | 5 sets / 1 months |
| Delivery Time: | 6~8weeks |
| Packaging Details: | Plywood cases |
| Accuracy Class: | 0.01% / 0.02% |
| Number Of Meter Positions: | 3 / 6 |
| Power Source: | YCS-103-X |
| Structure: | All-in-one |
| Usage: | Energy Meter Calibration, Lab Research |
| Power of the voltage output: | 3x200VA |
| Stability: | Better than 0.002% /h |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
>1. >Nation-level utility companies
>2. >Governmental bureaus of metrology
>3. >Big energy meter manufacturers
>4. >Laboratory of electric energy metering
| Technical Speciation | |
| Number Of Meter Positions | 3 / 6 |
| Accuracy Class | 0.01% / 0.02% |
| Power Source | YCS-103-X |
| Reference Standard Meter | ZERA: COM3003 RADIAN: RD33-233 EMH/MTE: K2006 GENY: SZ03A-K8 |
| Scanning Head | YCG-S Series |
| Voltage | |
| Test voltage output(Phase-Neutral) | 3x(40V~500V)(or customized) |
| Power of the voltage output | 3x200VA |
| Resolution | Better than 0.001% of full scale value of range |
| Stability | Better than 0.002% /h (integration time 150s) |
| Load regulation from 0~max. load | Better than 0.01% |
| Distortion factor | Better than 0.05% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Current | |
| Test current output | 3x (1mA~120A) max. to 230A |
| Power of the current output | 3x300VA |
| Resolution | Better than 0.001% of full scale value of range |
| Stability | Better than 0.002% /h (integration time 150s) |
| Load regulation from 0~max. load | Better than 0.01% |
| Distortion factor | Better than 0.05% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Phase angle | |
| Range | 0~360⁰ |
| Resolution | 0.01⁰ |
| Frequency | |
| Range | 45Hz~65Hz |
| Resolution | 0.001Hz |
| Error display | |
| Type of error display | Red LED |
| Resolution of error displays | 8 digitals |
| Other | |
| Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
| Ambient temperature | -10°C~+40°C |
| Relative humidity | 35%~85% |
>1. >The meter test equipment can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation
>2. >Testing mode: active power, reactive power, cross connected reactive power
>3. >Meters under testing: 1P2W , 3P4W, 3P3W
>4. >Simultaneously measure meters with same specifications but different meter constants
>5. >Automatic positioning rotor mark of disc of mechanical meter, with more efficiency
>6. >Creeping Test and Starting Test
>7. >With the protection function of short voltage circuit, overload and open current circuit
>8. >Aluminum alloy material, light and strong and corrosion resistant
>9. > The testing software with friendly Windows XP/ 7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,.
>1. >High quality product
>2. >Highest accuracy class: 0.01/0.02
>3. >Extremely high power stability
>4. >Influence test of voltage, frequency, and harmonic
>5. >Installing RS232, Ethernet communication port in each meter position.
>6. >Over 18 months long warranty and extends to 36 months in capable

|