| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Integrated BMS |
|---|---|
| Brand Name: | GCE |
| Model Number: | RBMS08-D75S-50A |
| Certification: | CE |
| Place of Origin: | CHINA |
| MOQ: | 2 |
| Price: | Negotiate with cara@hngce.com |
| Payment Terms: | T/T, L/C |
| Supply Ability: | 1000sets/month |
| Delivery Time: | 15 days |
| Packaging Details: | Bubble bag, foam, carton |
| Application: | home storage/off-grid/ESS/UPS/backup/Solar energy storage |
| Warranty: | 3 years for RBMS and 1 year for BMU/PCBs |
| Voltage: | 240V |
| Current: | 50A |
| Dimensions: | 480*433*100mm |
| Operating Tempreture: | -20~60℃ |
| Charge/Discharge Current: | 50A / 100A |
| Short Circuit Protection: | Yes |
| Style: | Slave and master all in one device |
| Power Consumption: | ≤10W |
| Basic Module: | Max. 15S |
| weight: | 10kg |
| color: | black |
| ODM & OEM: | acceptable |
| Company Info. |
| Hunan GCE Technology Co.,Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
GCE HV BMS Configuration:
One complete set of HV 75S240V 50A BMS includes:
Master BMS, Model#: RBMS08-D75S-50A, and its wire accessories, include 6p temperature sensing wires and 16p voltage sensing wires.
There are two different models for integrated BMS, one is a standalone model while the other one is parallel with its cost slightly higher than the standalone model.




GCE HV Integrated Master BMS and Accessories:
30-75S Integrated BMS
Voltage range:96V-240V
Current:50A/100A
Communication:CAN & RS485
Design: Master & slave all in one.

Temperature acquisition wire
Standard length is 600mm,900mm,1200mm
There are 3 temperature sensing probes per 15S wires. In total,
there are 12 probes in 60S and 15 probes in 75S.

Voltage acquisition wire
Standard length is 600mm,900mm,1200mm

GCE integrated BMS Characteristics:
※ Perfect self-checking and running status checking function, with
HMI display screen, system running information is clear at a
glance. | ※ Abundant communication interfaces---multiple RS485, CAN,
Ethernet, dry contact input and output interfaces, supporting
communication with most PCS and monitoring servers on the market. |

GCE integrated BMS Technical parameters:
| Item | Specifications and parameters | |
| System operating voltage range | 120 - 370 VDC | |
| Startup mode | DC start | |
| balance | Equilibrium type | Passive resistance equalization |
| Balanced current | 100mA ± 10mA (when cell at 3.50V) | |
| Sampling accuracy | ± 2℃ | |
| Voltage sampling | Sampling accuracy | single-cell ±20mV |
| Communication mode | Can: 1 channel (communication with PCs / UPS) | |
| RS485: 1 channel (communication with upper computer / PCS / UPS) | ||
| Display mode | 6-digit LED indicator, including | |
| 1-bit fault indication, 1-bit operation indication, 4-bit SOC power indication | ||
| HMI display: optional 3.5 inch | ||
| Rated current | 50A/100A | |
| (be selected according to customer needs) | ||
| Short circuit protection | Support 7.5KA 20ms | |
| Maximum overload capacity | 50A system transient: 70A/10S | |
| 100A system transient: 150A/10S | ||
| Alarm level | one Level | |
| Protection level | two levels | |
| Level 1 cut-off charge/discharge | ||
| Level 2 micro cut-off switch, system power down | ||
| Power consumption | ≤10W | |
| Weight | 4.5kg | |
| Withstand voltage rating | 1800VDC 1mA 1min | |
| Safety certification | Comply with CE certification standards | |
| Operating temperature | -20~60℃ | |
| Operating humidity range | <90 RH(40℃±2℃) | |
Download linkage of Specification:
GCE 30S-75S integrated BMS specification Ch-EN V2...
High Voltage BMS Application:

FAQs about GCE HV BMS:
|