| Product Name: | S6100A anesthesia machine |
| Ventilation mode: | IPPV, A/C, SIMV, SIGH, MANUAL |
| Gas source: | O2, N2O, AIR |
| Advantages: | ventilation modes, prioritizes patient safety |
| Pressure: | 280 kPa ~ 600 kPa |
| Voltage: | 100 ~ 240 V |
| Input power: | 80 VA |
| Power frequency: | 50/60 Hz |
| Company Info. |
| Better Health Technology Co.,Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
| Ventilation mode |
IPPV, A/C, SIMV, SIGH, MANUAL |
| Ventilator parameter range | |
| Flowmeter | O2 (0 ~ 10 L/min) N2O (0 ~ 10 L/min) or AIR (0 ~ 10 L/min) |
| Rapid oxygen supply | 25 L/min - 75 L/min |
| Tidal volume | 0, 20 mL ~ 1500 mL |
Maximum MV | ≥18 L/min |
| Frequence(Freq) | 1 /min - 100 /min |
| I:E | 2:1(1:0.5)- 1:6 |
| PEEP | 0 cmH2O - 30 cmH2O |
| Pressure triggering sensitivity (PTr) | -20 cmH2O - 0 cmH2O (Based on PEEP) |
| Flow trigger sensitivity (FTr) | 0.5 L/min - 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 70 cmH2O |
| SIGH | 0 (off) 1/100 - 5/100 |
| Apnea ventilation | OFF, 5s - 60s |
| Pressure limit | 20 cmH2O - 100 cmH2O |
| Alarm and protection | |
| The AC power failure alarm | Power failure or no connection |
| Internal battery backup low voltage alarm | < 11.3 ± 0.3 V |
| No tidal volume | ≤ 5 mL within 6 s |
| High oxygen concentration alarm | 19 % - 100 % |
| Low oxygen concentration alarm | 18 % - 99 % |
| High airway pressure alarm | 2 cmH2O - 100 cmH2O |
| Low airway pressure alarm | 0 cmH2O - 20 cmH2O |
| High minute volume alarm | Adult (5 L/min ~ 20 L/min) Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min) |
| Low minute volume alarm | 0 ~ 10 L/min |
| Continuous pressure alarm | (PEEP+1.5 kPa) over 16 s |
| Suffocation warning | 5 s - 60 s no spontaneous ventilation |
| The maximum limited pressure | ≤ 12.5 kPa |
| Fan error | Show on screen |
| Oxygen deficit | Show on screen |
| Monitoring parameter | |
| Frequence(Freq) | 0 /min - 100 /min |
| Tidal volume (Vt) | 0 mL - 2000 mL |
| MV | 0 L/min - 100 L/min |
| Oxygen concentration | 15 % - 100 % |
| Working condition | |
| Gas source | O2, N2O, AIR |
| Pressure | 280 kPa ~ 600 kPa |
| Voltage | 100 ~ 240 V |
| Power frequency | 50/60 Hz |
| Oscillogram |
| P-T (pressure - time) |
| F-T (flow - time) |
| P-V loop (pressure - volume loop) |
| Wooden case packing size |
| Wooden case packing size : L 790 * W 740 * H 1460 mm |
| G.W. :103 KG N.W. :76 KG |





|