2.5Mpa 20m 3Kg Fm200 Automatic Fire Extinguisher Tube With GB25972-2010 Standard

Categories Fire Detection Tube
Brand Name: xingjin
Model Number: WZ-Q/T-QZ3-XJ60
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Place of Origin: China
MOQ: 5 sets
Price: negotiation
Payment Terms: L/C, , D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 200 sets per week
Delivery Time: 10-15 working days after payment or receipt of L/C
Packaging Details: Plywood case
Storage pressure: 2.5Mpa
Capacity of agent: 3kg fm200
Zone management: Single
Pattern of extinguishing: Enclosed flooding
Standard of examination: GB25972-2010
Max length of detecting tube: 20m
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

2.5Mpa 20m 3Kg Fm200 Automatic Fire Extinguisher Tube With GB25972-2010 Standard

3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard


Parameter:

No.SpecificationTechnical parameter
1TypeFm200 direct type
2modelWZ-Q/T-QZ3-XJ60
3Working pressure2.5Mpa
4Max working pressure4.2Mpa
5Working temperature0-50℃
6Density of unit volume0.7kg/m3
7Max length of detecting tube20m
8Quantity of agent3kg

Description:


This gadget uses a pressurized fire trace tube coupled to an extinguishing agent store to detect fires. For this device, you can use carbon dioxide or HFC-227ea/FM200 as an extinguishing agent.


It would typically be built to accommodate both direct release and indirect release discharge types. When a fire first ignites, the fire trace activates the system, which then causes an extinguishing agent to be delivered through the fire trace tube. A straight release is what it's known as. Another method, which we refer to as "indirect release," uses the fire trace tube to release an extinguishing agent as soon as it senses a fire.


The lack of fixed equipment can be effectively treated using the fire trace extinguishing device. because it can be utilized in locations where installing fire alarm systems, pipes, or nozzles is challenging, including narrow areas or unusual situations.


Applications:


Power plants, communications, broadcasting, petrochemical, railway ans so on system.



Working principle:


The fire detecting tube can be fixed anywhere a fire can easily start because to its soft properties. As a result, a fire inside the cabinet has a chance of spreading quickly and harming the fire detection tube. When the fire detecting tube breaks, the air pressure changes, causing the fire agent to emerge and spray out of the hole where it broke to put out the fire. The small alarm bell that chimes on top of the fire extinguisher alerts users to the presence of a fire and requests that they check it out and refuel the system.


Components:


To build a system for this extinguishing device, no electrical components or pipe fittings are required. It might potentially serve as a system for suppressing fires.


A cylinder, a fire detecting tube with a maximum length of 25 meters, a container valve, and two different types of agents—co2 and fm200—make up the direct type fire detecting tube fire suppression system.


The components of the indirect type fire detecting tube fire suppression system are identical to those of the direct type with the addition of a release tube. In contrast to the direct type, where the fire detecting tube can be used for both detecting and releasing, this approach only uses the fire detecting tube for the detecting function, necessitating the inclusion of a release tube.


The fire detecting tube fire suppression device has the following advantages:


1. Easy transportation and installation. The only thing left to do after installing the cylinder is to install the detecting tube around a potential source of fire because this system integrates fire fighting and alarm function together and does not require matching electrical elements and pipe fittings.


2. The manual start mode. The system may be turned on without any power. The working principle of this device relies on internal storage pressure rather than an external force to activate it. The agent will release after the fire breaks the sensing tube.


3. Not much room is occupied. Instead of protecting a protected zone, this approach is more suited for securing a system like a communications network. The cylinder is fixed to the outside cabinet and won't take up much space.​​

Company Introduction:


Guangzhou Xingjin Fire Equipment Co., Ltd., a company that plays a significant role in communication between China and the rest of the globe, is situated in this city and is surrounded by excellent transportation and a lovely environment. We are a manufacturer, and we focus on the research and development of HFC-227ea (FM200) products with the help of our experienced and qualified staff, which includes the program design team, the skilled installation team, the quality detecting team, and the after-sale service team. These days, many of our well-known FM200 products are in use, including the automated FM200 fire extinguisher (ceiling mounted style), the cabinet type FM200 fire suppression system, the pipe network FM200 fire suppression system, the fire detecting tube suppression system, and the automatic fire suppression tube.


Quality 2.5Mpa 20m 3Kg Fm200 Automatic Fire Extinguisher Tube With GB25972-2010 Standard for sale
Send your message to this supplier
 
*From:
*To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0