Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Financial Equipment >

Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000

Categories Temperature Humidity Chamber
Brand Name: iqualitrol
Model Number: QYG-5000
MOQ: 1 Set
Payment Terms: T/T
Supply Ability: 5 Sets per month
Delivery Time: 30 Working Days
Packaging Details: Plywood Pallet
application: simulating temperature and climatic indoor and outdoor conditions with global irradiation
Light Wavelength: Full-spectrum light DIN75220 and GJB150.17-86, simulating sunlight 280-3000nm
Air conditioning duct: Heater, evaporator (also dehumidifier), humidifier, overheat protector, water supply and drainage devices
Observation window: 1 transparent electric heating film anti-condensation insulated tempered glass window
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000


Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000


Brief Introduction:

The Q1-TEST Solar Simulation Test Chambers are state-of-the-art test units for simulating temperature and climatic indoor and outdoor conditions with global irradiation.


The QYG-5000 simulates direct sunlight, heat, cold and humidity in order to test the many small and large items of day-to-day life that are subjected to different levels of solar radiation.


These environments affect the service and operating conditions of various products exposed to these environmental extremes. They cause colors to fade and accelerate the ageing of materials.


Technical Specifications:

Name and modelSunlight Simulation Test Chamber QYG-5000
Dimension and weight
Internal Volume5600L
Internal DimensionW1200mm×H1800mm×D2600mm
External DimensionW1450mm×H2750mm×D3850mm
Net weightAbout 1950kg
Performance
Test ConditionsAmbient temperature is 25℃, relative humidity ≤85%
Under the condition that there are no samples in the test chamber
Test MethodsGB/T 2423.2 Test B: High Temperature Test Method,
GB/T 2423.3 Test Ca: Constant Damp Heat Test,
GB/T 2423.24 Test Sa: Simulation of Solar Radiation on the Ground,
GJB 150.3A High Temperature Test,
GJB 150.9A Damp Heat Test,
GJB 150.7A Solar Radiation Test (Test Curve), DIN 75220
Temperature Range-20℃~+150℃
Temperature fluctuation0.5℃(if by GB/T 5170.2, then indicates ±0.25℃)
Temperature deviation±1.5℃
Temperature uniformity

1.0℃( Damp heat test ,humidity >90%RH)

1.5℃(Temperature <100℃)

2.0℃ No sunlight

Light Parameters
Light Illumination Wavelength and Test ConditionsFull-spectrum light DIN75220 and GJB150.17-86, simulating sunlight 280-3000nm
Irradiation intensity(50–1500) ±10% W/m² (adjustable, minimum setting is 50 W/m², distance between light source and sample >0.76 m, distance adjustable), and can continuously record during the test, equipped with a lux meter
Irradiation uniformityWithin 1㎡: 1000W/m2±100, 800W/ m2±80 W/m2
Blackboard temperatureDisplay and configure 1 BST; (blackboard temperature is not controlled during high and low tests)
Optical filter glassEquipped with DIN 75220 optical filter glass (removable)
Lamp positionThe lamp tube is outside the equipment, at a distance of no less than 1.5 meters from the bottom of the equipment, located at the top.
Temperature and Humidity Rise and Fall Requirements (No Light)
Heating Time
-20℃ →+120℃:≥2℃/min

Cooling Time

(Ambient Temperature 23~28℃)

+120℃ →-20℃:≥1℃/min
Humidity Range
(Humidity range when the light is off)
(10~98)%RH
Relative humidity deviation

±2.0%RH(Humidity>75%RH)

±3.0%RH(Humidity≤75%RH)

Work noise≤70dB(A)( Measured in a soundproof room with few echoes at an ambient temperature of 25°C; the average of 8 test points was taken; each test point is 1 meter horizontally from the noise source and 1 meter above the ground. )
Structural Features
Thermal insulation enclosure structureExterior wall material: double-sided galvanized steel sheet, surface sprayed with plastic (q1-test standard beige)
Interior wall material: stainless steel sheet SUS304
Cabinet insulation material: rigid polyurethane foam, fiberglass
Door insulation material: fiberglass
Air conditioning ductFans: 4
Heater, evaporator (also dehumidifier), humidifier, overheat protector, water supply and drainage devices, dry bulb temperature sensor, wet bulb temperature sensor, wet bulb water pan
DoorDouble-hinged door, left hinge, right handle (when facing the front of the cabinet door)
Door equipped with an observation window and internal lighting
Door frame equipped with an anti-condensation electric heating device
Observation window1 transparent electric heating film anti-condensation insulated tempered glass window (located on the door)
Visible area approximately: W350mm × H500mm
Window frame is equipped with an anti-condensation electric heating device
Test Ports2pcs, φ100mm, on left side of chamber
Light1pc, 3W, High-efficiency long-life LED light source, located on the door
Control panelController display screen, USB interface, RJ network interface
Main power, over-temperature protection controller (right side)
Standard Delivery
ShelfAdjustable stainless steel sample rack, 1 tier, load capacity (evenly distributed): 50kg/tier
(Total cumulative load of samples inside the box should not exceed: 100kg)
CasterSix swivel caster wheels.
Air conditioning system
Heat transfer methodsAir circulation forced convection heat transfer
Air circulation deviceCentrifugal fan, long shaft with external motor drive
Air heating methodNickel-chromium alloy electric heating wire heater
Heater control method: Contactless equal-cycle pulse width modulation, SSR (solid state relay)
Heater power: 12kW
Air cooling methodEvaporator direct cooling
Refrigeration system
Way of workingAir-cooled dual refrigeration system
Refrigeration compressorMechanical compressor
CondenserFinned Tube Heat Exchanger
Condensing EvaporatorPlate heat exchanger
EvaporatorFinned Tube Heat Exchanger
Throttle deviceElectronic pulse quick-opening cold-end flow cutoff method
RefrigerantR404a R23 ( The ozone depletion index is 0 in all cases)
Refrigeration machine control methodThe control system automatically adjusts the chiller operation to the optimal energy-saving condition according to test conditions
Compressor suction gas cooling circuit
Evaporation pressure regulating valve
Condenser fan automatic speed control
Humidification system
HumidifierBoiler-type heating and humidification method
Stainless steel armored heater
Heater control method: contactless equal-cycle pulse width modulation, SSR (solid-state relay)
Water level control device, heater dry-burn protection device
Humidifier power: 3.6 kW
Humidification system water supply
Water supply methodPump lift
Water supply device locationSide water tank (electric suction and automatic water supply)
Water tank20L
Water qualityResistivity≥500Ω·m
Other configurations
Power cableOne five-core (three-phase four-wire with protective earth) cable (about 5 meters long)
Specimen power supply control terminal (optional)Relay contact control, within AC240V, 2A (when operating normally, the contacts are closed; when the equipment is stopped or faulty, the contacts are open). Strongly recommend that users use control terminals to control the power on/off of the test sample, to ensure that the power connected to the test sample is reliably cut off when the equipment fails or stops.
Main power leakage circuit breakerMain power input, leakage circuit breaker and overload circuit breaker
Rated residual current: 30mA
Safety device
Test ChamberAdjustable over-temperature
Test chamber temperature fuse
Air regulation channel limit over-temperature
Fan motor overheating
Power distribution control cabinet opens power-off protection
Cabinet door opening (during operation) triggers alarm and multiple openings cause refrigeration system fault alarm protection
Refrigeration systemCompressor Overheating
Compressor Overcurrent
Compressor Overpressure
Humidification systemHumidification heat pipe overheat protection
Humidification water shortage abnormal
Water tank water shortage abnormal
Electrical control systemMain power phase sequence and phase loss protection
Main power overvoltage and undervoltage protection
Leakage protection
Overload and short circuit protection
Power Supply
AC380V/50Hz three-phase four-wire protective grounding
Voltage range: AC (380±10%) V
Allowable frequency fluctuation range: (50±0.5) Hz
Grounding resistance of the protective ground wire should be less than 4Ω
It is required that the user provides an air switch or power switch of appropriate capacity at the installation site for the equipment, and this switch must be used exclusively for this equipment (recommended power switch capacity: 83A)
Current45A
Maximum continuous operating power

36.5kW

(Data obtained from the test after running for one hour at an ambient temperature of 25°C, without a sample, under stable operating conditions)

Quality Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000 for sale
Send your message to this supplier
 
*From:
*To: DongGuan Q1-Test Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0