| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Temperature Humidity Chamber |
|---|---|
| Brand Name: | iqualitrol |
| Model Number: | EFS-PRO150 |
| MOQ: | 1 Set |
| Payment Terms: | T/T |
| Supply Ability: | 5 Sets per month |
| Delivery Time: | 30 Working Days |
| Packaging Details: | Plywood Pallet |
| rainfall area: | Effective rainfall area 800mm * 1600mm |
| Rainfall intensity: | 100mm~280mm/M2/H, adjustable |
| wind speed: | 5~18 m/s, allowing raindrops to uniformly hit the test product at an angle of 0~45° |
| rainfall duration: | Rain Test Duration: Continuous rainfall duration ≥4H, adjustable, max 24H |
High Pressure Washdowns
Rain Test Chamber EFS-PRO150 to Uncover Waterproof Vulnerabilities
Brief Introduction:
Rain test chamber is an environmental simulation device that replicates real-world rain exposure, road splash, and high-pressure washdowns through programmable water spray systems.
Its primary function is to uncover potential product vulnerabilities—such as seal failure, material degradation, or electrical short circuits—long before the product enters the field.
Technical Specifications:
| Internal Dimension | 2000L |
| Chamber Size | Width * Depth * Height 1000×2000× 1000mm |
| External Dimension | About 4500mmx2800mmx3500mm (Width * Depth * Height) The actual situation is subject to the final engineering design. |
| Power Supply | AC380V±5%, 50Hz±1, Three-phase four-wire grounding line (3/N/PE), grounding resistance less than 4Ω |
| Maximum operating power | About 35KW(The final construction design shall prevail) |
| electric current | About 68A (The final construction design shall prevail) |
| Installation Site | The placement area should have a level floor, good ventilation, and be free of flammable, explosive, or corrosive gases or dust; the site should have no strong vibrations and avoid direct sunlight; there should be no strong electromagnetic radiation sources nearby; the floor load-bearing capacity should be no less than 600kg/m²; environmental temperature requirement: 5℃~30℃ for optimal performance; environmental humidity requirement: ≤85%RH; environmental atmospheric pressure requirement: 86KPa~106KPa; adequate maintenance space should be left around the equipment. |
| Compressed air | Compressed air supply pressure: 0.6 MPa~0.7 MPa; The air source quality must at least meet ISO8573.1 Class 2.8.3 standard. |
| Main Specifications | |
| Wind-driven rain test | Room Temp (RT+10℃) to +55℃ |
| Preheating temperature: ensure the specimen temperature is 10℃ higher than the water temperature | |
Horizontally adjustable wind speed: 5~18 m/s, allowing raindrops to uniformly hit the test product at an angle of 0~45°. During rain tests with wind, the position of the rotating table in the test chamber can be adjusted so that the top drip tray is on different vertical axes, enabling raindrops to strike the product at angles of 0~45°. | |
| Effective rainfall area: 800mm * 1600mm | |
| Air vent cross-sectional area: 800mm *1600mm | |
| Rainfall intensity: 100mm~280mm/M2/H, adjustable | |
Raindrop speed: 9m/s (By adjusting the height of the top drip tray to allow rainwater to accelerate in free fall, the rain droplet speed of 9 m/s is achieved at the maximum specimen height of 1 m.) | |
| Raindrop diameter: 0.5mm~4.5mm | |
| Rain Test Duration: Continuous rainfall duration ≥4H, adjustable, max 24H | |
| Anti-blocking measures: The rain plate has a needle anti-clogging automatic pressurization and air-blowing function | |
| Others: Fluorescein or similar water-soluble dyes can be added to rainwater. | |
| Strengthening test parameters | Nozzle pressure: 276kPa~300kPa |
| Spray surface: For a sample, at least one nozzle should be installed within an area of 0.56 ㎡ receiving the rainfall; there are 5 sprayed surfaces, and the distance between the spray surfaces and the specimen can be adjusted according to the size of the specimen to meet the 48mm requirement. The spray surface near the test chamber door is easy to disassemble and install. | |
| Drip Test Parameters | Test time≥40min |
| Nozzle aperture: 1.0~1.2mm | |
| Spray angle: 60° | |
| Others: Fluorescein or similar water-soluble dyes can be added to rainwater. | |
| Effective rainfall area: 1000mm*1000mm | |
| Rainfall intensity: 100~300L/㎡/h, adjustable | |
| Raindrop diameter: 0.5~4.5mm | |
| Room temperature: (RT+10℃) to +55℃ | |
| Preheating temperature: ensure the specimen temperature is 10℃ higher than the water temperature | |
| Drip hole spacing: 25mm * 25mm | |
| Automatic height adjustment: Automatically adjusts the height of the drip tray according to the height of the sample | |
| Raindrop speed: 9m/s, (By adjusting the height of the top drip tray to allow rainwater to accelerate in free fall, the rain droplet speed of 9 m/s is achieved at the maximum specimen height of 1 m.) | |
| Rain Test Duration: 1~9999min, adjustable | |
| The rain tray has a drip hole anti-clogging automatic pressurization and air blowing function | |
| Others: Fluorescein or similar water-soluble dyes can be added to rainwater. | |
| Rotary Test Bench | Diameter: Φ800mm rotary table |
| Material: aluminum alloy plate, set installation screw holes, set anti-slip and anti-tip devices | |
| Turntable speed: 2~7 r/min, speed adjustable | |
| Max load 10 0kg | |
| Top drip tray | The drip tray is driven by a motor, with adjustable height, lifting adjustment range: 0~2500mm |
| Meet the test requirements stipulated by Procedure I, Procedure II, and Procedure III, and the requirements for the raising and lowering drip pan | |
| Tray area: 1000mm * 1000mm | |
| Nozzle Installation | Modular water nozzle, adjustable and removable for replacement |
| Rainwater treatment | Automatic waterway recovery, filtration, and recycling |
|