| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Ultrasound Probe Repair | 
|---|---|
| Brand Name: | GE | 
| Model Number: | 4C | 
| MOQ: | 1 | 
| Price: | Negotiable | 
| Payment Terms: | T/T, Western Union | 
| Delivery Time: | 1-3 work days | 
| Packaging Details: | Neutral Package | 
| Applications: | OB/GYN, Abdominal, Vascular, Urology | 
| Category: | medical repair | 
| Warranty: | 60 days | 
| Type of Array: | Ultrasound equipment | 
| Condition: | Original | 
GE Logiq 9 Ultrasound Probe 4C Convex Array Transducer Medical Use
1. Type: Convex
2.Compatible system: Logiq 5 Pro, Logiq 7, Logiq 9, Logiq A5, Logiq P5, Logiq P6, Logiq
P7, Logiq S6, Vivid 7 Expert
3. Frequency: 2-5 MHz.
4. Application: OB-GYN, urology, pediatrics and abdominal imaging applications
5. With 60 days warranty after fixed and 3-5 working days to repair
| 2D Probe Repair | |
| Service Brand | GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison | 
| Service Type | Linear,Convex,Phased,Sector,Endocavity | 
| Repair Range | Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair | 
Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)
| Common ultrasound probe damage | Solutions | 
| Lens cap damage | Lens cap replacement | 
| Fluid and oil leaks | Lens cap replacement, oil reservoir repair and replacement | 
| Cable cuts | Cable patches, possible cable replacement | 
| Inoperative steering | Motor repair | 
| Connector housing electrical damage | Minor electrical repairs, pin module replacement | 
| Weak or dead elements, dropouts in an image | Array ball replacement, oil reservoir repair and replacement | 
Parts of GE probes we can repair:
| Brand | Model | Compatible System | 
| GE | 3.5C | Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6/Vivid7 | 
| GE | 3C | Logiq 3/ Logiq 5 | 
| GE | 3Cb | Logic 200 Pro | 
| GE | 3CRF | Logiq S6 | 
| GE | 3CRF-D | Logiq S8/ Logiq E9 | 
| GE | 3SP | LOGIQ P | 
| GE | 3Sp-D | Voluson E6/Voluson E8 / Bt08 & Higher version | 
| GE | 3S | vivid & Logiq series | 
| GE | 3S-RS | Loqigbook/XP/ Vivid-I | 
| GE | 3S-SC | venue 40 | 
| GE | 3S-RC | Logiq C5/ Logiq C2/ Logiq C3 | 
| GE | 3SC-RS | Vivid S5/ Vivid iq/ Vivid i | 
| GE | 3.8CA | Logiq P3 | 
| GE | 3V-D | Vivid E9 | 
| GE | 3.8C-RC | Loqig C2/Logiq C3/ Logiq C5/ Logiq premiums | 
| GE | 4C | Logiq & Vivid Series | 
| GE | 4C-RC | Logiq C2/Logiq C3/Logiq C5/Logiq Premium | 
| GE | 4C-RS | Vivid i Square/ Logiq e/ Vivid e | 
| GE | 4C-SC | Venue 40 | 
| GE | 4C-A | Voluson 730 | 
| GE | 4C-D | Voluson E6/ E8 and Vivid E9 | 
| GE | 4D3C-L | Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6 | 
| GE | 4V-D | Vivid E9 | 
| GE | 4S | Logiq and Vivid series | 
| GE | 5S | pediatric cardiac | 
| GE | 5S-RS | Vivid q/ Vivid i/Vivid S5/Vivid S6 | 
| GE | 6.5C-RC | Vivid q/ Vivid i | 
| GE | 7L | Logiq and Vivid series | 
| GE | 7L-RC | Logiq C2/ C5/ Logiq Premium | 
| GE | 739L | Logiq 500 Pro/Vivid 3/Logiq 400 MD/Logiq 500 MD | 
| GE | 7S | Logiq9/ Logiq 7/ Logiq S6/ Logiq 5/ Logiq 3 /Vivid 7/Vivid 3 | 
| GE | 7.5L-RC | Logiq C2/Logiq C3/Logiq C5/Logiq Premium | 
| GE | 8C | Logiq & Vivid series | 
| GE | 8C-RS | Voluson i/ Voluson e/ Logiq i/ Logiqbook XP/ Logiqbook/ Vivid i (from rev. 6.1.0)/ Vivid S5 | 
| GE | 8L-RS | Logiq e/ Vivid e/ Vivid i and Logiq Book XP | 
| GE | 9L | Vivid 7 Pro/Vivid 3/Logiq 9/ Logiq 7/Logiq 5/Logiq 3/ Logiq 400 | 
| GE | 9L-D | Voluson E6/Voluson E8/Vivid E9 | 
| GE | 9L-RS | logiq e/ vivid e/ vivid I/ vivid q/ vivid s5/ vivid s6 | 
| GE | 10Lb-RS | Logiq book | 
| GE | 10S-RS | Logiq Book/ Logiq e/ Vivid e/ Vivid i/ Logiq i/ Vivid i Square | 
| GE | 10L | Logiq 3/5/7/9/ Vivid 3/4/A5/P5/7 Expert/7 Pro/ Logiq S6 | 
| GE | 11L | Logiq P5/A5/A5Pro/ Logiq P6/P6 Pro | 
| GE | 11L-D | premium GE ultrasound machines | 
| GE | 12L | Logiq & Vivid series | 
| GE | 12L-RS | Logiq e/ Logiq l/ Vivid e/Vivid I Voluson e/Voluson I/Vivid Q/Vivid S5/ Vivid S6 | 
| GE | 12L-SC | Venue 40 | 
| GE | 12S-D | Vivid E9 | 
| GE | AB2-7 | Voluson S6/ Voluson S8/Voluson 730 | 
| GE | AC2-5 | Voluson 730 | 
| GE | BE9C | Logiq series | 
Quality Control
Rongtao Medical’s team of expert technicians perform high-level maintenance and repair service. All our partners can be assured that our repair will meet or exceed all manufacturer’s specifications, including all major manufacturers ( GE, Hitachi Aloka, Toshiba Canon,Siemens,Samsung Medison, Biosound Biosound,Mindray---)
Our stock have been sold to more than 50 countries around the world, and comply with the norms and requirements of the global medical market.
Rongtao Medical is expecting to make it easier and more affordable for every hospital, clinic and medical partner to have the very best equipment, parts and repair service.
Picture

|   | 
 Toshiba PVU 375BT Ultrasound Probe Repair For Physical Damage
                                                                                        
                                                        
                        
                        
                        
                                                            Toshiba PVU 375BT Ultrasound Probe Repair For Physical Damage
                                                    
                        
                     Damage cable sheath Ultrasound Probe Repair  S5 1
                                                                                        
                                                        
                        
                        
                        
                                                            Damage cable sheath Ultrasound Probe Repair  S5 1
                                                    
                        
                     Repair Service For Bulging Probe GE 11L-D Ultrasound Transducer
                                                                                        
                                                        
                        
                        
                        
                                                            Repair Service For Bulging Probe GE 11L-D Ultrasound Transducer
                                                    
                        
                     GE RAB2 5 D Ultrasound Probe Repair Strain Relief
                                                                                        
                                                        
                        
                        
                        
                                                            GE RAB2 5 D Ultrasound Probe Repair Strain Relief
                                                    
                        
                     GE RAB6 D 4d Probe Repair Motor Control Failures
                                                                                        
                                                        
                        
                        
                        
                                                            GE RAB6 D 4d Probe Repair Motor Control Failures
                                                    
                        
                     Siemens Ultrasound Transducer Repair For Lens Fault
                                                                                        
                                                        
                        
                        
                        
                                                            Siemens Ultrasound Transducer Repair For Lens Fault
                                                    
                        
                     4D Samsung V5 9 Ultrasound Probe Repair Replace Strain Relief
                                                                                        
                                                        
                        
                        
                        
                                                            4D Samsung V5 9 Ultrasound Probe Repair Replace Strain Relief
                                                    
                        
                     GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement
                                                                                        
                                                        
                        
                        
                        
                                                            GE RAB4 8 D Ultrasound Probe Repair Crystal Replacement
                                                    
                        
                     Ultrasound Repair Service For Probes Aloka UST-5548 Lens Replacement Replace Lens for probes
                                                                                    
                        
                        
                        
                                                            Ultrasound Repair Service For Probes Aloka UST-5548 Lens Replacement Replace Lens for probes
                                                    
                        
                     Replace Lens Ultrasound Probe Repair GE RIC5 9 D
                                                                                        
                                                        
                        
                        
                        
                                                            Replace Lens Ultrasound Probe Repair GE RIC5 9 D