Variable Frequency Very Low Frequency Test Customized Input Power Supply
Product Name: Very Low Frequency tester VLF-40KV
Equipment Description:
The VLF testers (Generator) are suitable for Testing cables, transformers, switchgear, Rotating machinery, and other Electrical apparatus.
Specifications:
1. Input: 120 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage. 50KV
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ± 3%.
6. Positive and negative voltage peak errors: ≤ 3%.
7. Voltage waveform distortion: ≤ 5%
8. Construction: In two units: Controller and Booster...
9. Ambient conditions of use: Temperature Indoor and outdoor: -10ºC
to + 50ºC.
10. Humidity: ≤ 85%
Main Functions:
1. Easiest to use Fully automatic microcontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV
side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable
insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from
transients
14. Short circuit protected.
15. Status display of all important safety functions and messages.
16. Safe, easy to use operation with emergency off and key switch
lock-out.
17. Fully integrated discharge circuit to safely ground the DUT
after testing.
18. Zero start interlock.
19. Zero voltage switching.
Models:
| 
 | Output | Load Capacity | Control Unit | Booster | Fuse Tube | ||
| 
 | Dim. | Wt | Dim. | Wt | |||
| VLF-30/1.1 | 30KV/20mA | 0.1Hz ≤ 1.1uF | 28× 37× 22 | 4 | 33× 18× 34 | 25 | 5A | 
| VLF-40/1.1 | 40KV/30mA | 0.1Hz ≤ 1.1uF | 28× 37× 22 | 4 | 35× 20× 36 | 35 | 6A | 
| VLF-50/1.1 | 50KV/40mA | 0.1Hz ≤ 1.1uF | 28× 37× 22 | 4 | 37× 24× 39 | 45 | 7A | 
| VLF-60/1.1 | 60KV/50mA | 0.1Hz ≤ 1.1uF | 28× 37× 22 | 4 | 33× 18× 34 | 25+25 | 10A | 
| VLF-70/0.5 | 70KV/55mA | 0.1 Hz, ≤ 0.5µ F | 28× 37× 22 | 4 | 33× 18× 34 | 25+35 | 10A | 
| VLF-80/0.5 | 80KV/60mA | 0.1 Hz, ≤ 0.5µ F | 28× 37× 22 | 4 | 33× 18× 34 | 25+45 | 12A | 
When using it, the capacitance of the sample should not exceed the rated capacity of the instrument. The over low capacitance of the sample will affect the output wave form. If the capacitance is less than 0.05μF, the instrument cannot output normally. In this situation, the tester needs to have a 0.05μF compensation capacitor(provided by our company) in parallel connection as an auxiliary output when the sample’s capacitance is less than 0.05μF.
|   | 
 Real Time Display VLF Test Set For Medium High Voltage Cable Dielectric Withstanding
                                                                                    
                        
                        
                        
                                                            Real Time Display VLF Test Set For Medium High Voltage Cable Dielectric Withstanding
                                                    
                        
                     VLF 0.1Hz 40kV Very Low Frequency AC Hipot Test Set for Power Cable
                                                                                    
                        
                        
                        
                                                            VLF 0.1Hz 40kV Very Low Frequency AC Hipot Test Set for Power Cable
                                                    
                        
                     0.1Hz 0.05Hz 0.02Hz Low Frequency VLF Test Set for AC Hipot Cable Test
                                                                                    
                        
                        
                        
                                                            0.1Hz 0.05Hz 0.02Hz Low Frequency VLF Test Set for AC Hipot Cable Test
                                                    
                        
                     Single Phase Very Low Frequency Hipot Test Equipment 30KV For High Voltage Cable
                                                                                    
                        
                        
                        
                                                            Single Phase Very Low Frequency Hipot Test Equipment 30KV For High Voltage Cable
                                                    
                        
                     Very Low Frequency AC Hipot VLF Test Set Electric Cable Fault Tester ISO Approve
                                                                                    
                        
                        
                        
                                                            Very Low Frequency AC Hipot VLF Test Set Electric Cable Fault Tester ISO Approve
                                                    
                        
                     0.1Hz Cable Tester High Voltage Vlf Hipot Instruments30KV 40KV 50KV 60KV 80KV
                                                                                    
                        
                        
                        
                                                            0.1Hz Cable Tester High Voltage Vlf Hipot Instruments30KV 40KV 50KV 60KV 80KV
                                                    
                        
                     Digital Display AC Hipot VLF Test Set For 0.1Hz Cable AC Withstand Voltage Tester
                                                                                    
                        
                        
                        
                                                            Digital Display AC Hipot VLF Test Set For 0.1Hz Cable AC Withstand Voltage Tester
                                                    
                        
                     AC Hipot Test Set High Voltage Tester VLF Cable Testing Equipment AC 220V 50Hz
                                                                                    
                        
                        
                        
                                                            AC Hipot Test Set High Voltage Tester VLF Cable Testing Equipment AC 220V 50Hz
                                                    
                        
                     80KV Cable Testing Very Low Frequency VLF Test Set With Sine Wave Output
                                                                                    
                        
                        
                        
                                                            80KV Cable Testing Very Low Frequency VLF Test Set With Sine Wave Output
                                                    
                        
                     Variable Frequency Very Low Frequency Test Customized Input Power Supply
                                                                                    
                        
                        
                        
                                                            Variable Frequency Very Low Frequency Test Customized Input Power Supply