| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Transformer Testing Equipment | 
|---|---|
| Brand Name: | Huaying | 
| Model Number: | HYZC-2A | 
| Certification: | ISO | 
| Place of Origin: | Wuhan Hubei China | 
| MOQ: | 1 Set | 
| Price: | Negotiable | 
| Payment Terms: | T/T L/C | 
| Supply Ability: | 200 sets per month | 
| Delivery Time: | 7 Working Days | 
| Packaging Details: | Wooden Case | 
| Constant current source: | 2A | 
| Measuring precision: | 0.5 grades | 
| Resolution: | 1μΩ | 
| Power supply: | AC 220V and DC12V. | 
| Dimension: | 335×275×175mm3 | 
| Weight: | 2.8KG | 
1. Product Name:
Winding Resistance Tester HYZC-2A
2. Equipment Description:
The HYZC-2A type transformerwinding resistance tester (micro-ohmmeter) is a high precision new generation product that can replace DC Wheatstone Bridge and double-arm Bridge. The device adopts the advanced starting power constant current source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperature or test current value, it overcomes the shortcoming that the LED display ambient value reading of other similar product is not convenient to read under the sun, at the same time it has the automatic arc extinguishing function.
The device has the advantages of quick speed measuring, high precision, visual display, strong anti-interference capability, small cubage, economical power consuming, stable and reliable test data, not affected by personal factor. It is an ideal device to measure various sensible loaded resistance and low voltage starting contact resistance, line and cable resistance and welded seam interface. The product is a quickest measuring device to measure the DC resistance of current domestic large inductance equipment such as power transformer; its speed is over one hundred times quicker than the bridge. The chargeable cell set (12V) is equipped inside the device.
The device is AC, DC two purpose, it is convenient to use when there is no AC power source in the site and field measuring.
3.Technical Parameters:
| Using condition: | Ambient temperature: 0℃--40℃ Relative temperature: ≤85℃RH | 
| Measuring scope: | 1uΩ—20mΩ; 20--200mΩ; 0.2--2Ω; 20--200Ω; 200Ω—2kΩ; 2kΩ-20 kΩ;20 kΩ-200 kΩ | 
| Measuring precision: | 0.5 grades | 
| Resolution: | 1μΩ | 
| Constant current source: | 2A | 
| Working voltage: | DC11V~14V (the lead-acid chargeable cell set), capacity1.2Ah. | 
| Power consumption: | ≤15W | 
| Exterior dimension: | 335×275×175mm3 | 
| Weight: | 2.8kg | 
|   | 
 Automatic Three Phase Power Transformer Turn Ratio and Vector Group Tester
                                                                                    
                        
                        
                        
                                                            Automatic Three Phase Power Transformer Turn Ratio and Vector Group Tester
                                                    
                        
                     DLA test unit Tangent Delta Tester
                                                                                    
                        
                        
                        
                                                            DLA test unit Tangent Delta Tester
                                                    
                        
                     High precision Winding Resistance Tester 2A quick speed measuring the DC resistance strong anti-interference capability
                                                                                    
                        
                        
                        
                                                            High precision Winding Resistance Tester 2A quick speed measuring the DC resistance strong anti-interference capability
                                                    
                        
                     Professional Design Transformer Load and No-load tester with Wide Voltage Range
                                                                                    
                        
                        
                        
                                                            Professional Design Transformer Load and No-load tester with Wide Voltage Range
                                                    
                        
                     Transformer Ratio Meter applied in Z type with wide testing range
                                                                                    
                        
                        
                        
                                                            Transformer Ratio Meter applied in Z type with wide testing range
                                                    
                        
                     20 A Three Phase Transformer Winding Resistance Test Set Fast Measuring
                                                                                    
                        
                        
                        
                                                            20 A Three Phase Transformer Winding Resistance Test Set Fast Measuring
                                                    
                        
                     Strong Anti Jamming Transformer Testing Equipment 20A For Measuring Winding Resistance
                                                                                    
                        
                        
                        
                                                            Strong Anti Jamming Transformer Testing Equipment 20A For Measuring Winding Resistance
                                                    
                        
                     Fast Speed Transformer Turns Ratio Meter Z Type Transformer Winding Wide Testing Range
                                                                                    
                        
                        
                        
                                                            Fast Speed Transformer Turns Ratio Meter Z Type Transformer Winding Wide Testing Range
                                                    
                        
                     8.0 KG Transformer Testing Equipment Frequency Response Characteristic Of Winding
                                                                                    
                        
                        
                        
                                                            8.0 KG Transformer Testing Equipment Frequency Response Characteristic Of Winding
                                                    
                        
                     Power Transformer No Load / Load Testing Equipment With Wide Voltage Range
                                                                                    
                        
                        
                        
                                                            Power Transformer No Load / Load Testing Equipment With Wide Voltage Range