Brand Name: Macy
Model Number: UL-2000
Certification: Rosh/ISO/CE
Place of Origin: China
MOQ: 1set
Price: 7742USD-8358USD
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000pcs/m
Delivery Time: 5-10work days
Packaging Details: carton
Product Name: UL-2000
key words: compact size and portable package
minimum sample size: 0.5ul
Wavelength range: 190-850nm
Optical Distance: 1mm/0.2mm
Wavelength AccuracyAccuracy: 1nm
Optical path length: 1mm/0.2mm/0.05mm
Spectral resolution: ≤0.3nm(FWHM at Hg 253.7nm)
Wavelength range accuracy: 0.002Abs(1mm Distance)
Detector: imported Marine optics 3648 pixel linear CCD array (spectrometer sequence code is required)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Macy Lab Nanodrop Spectrophotometer Micro Volume 3648 Pixel Linear Ccd Array Detector

Detailed Product Description

Wavelength Band: 190-850nm Optical Distance: 1mm/0.2mm

Wavelength Resolution: ≤0.3nm(FWHM At Hg 253.7nm) Minium Sample Capacity: 0.5ul

Sample Pedestal Material: 304 Stainless Steal And Quartz Test Accuracy: 0.1~5 Abs.±0.01Abs 5~80 Abs. ±2%

High Light: 850nm laboratory spectrometer,0.5ul laboratory spectrometer,ODM Laboratory Spectrometer


Micro-Volume UV/VIS Spectrophotometer

Model:UL-2000

Product description, technical parameters and configuration

Spectrophotometer is an important analysis instrument wildly applied in research of physics, chemistry, biology, medicine, material, enviroment and modern production management of chemistry, medicine, enviroment test, metallurgy. Spectrophotometer is the instrument for quantitative and quantitative analysis by spectrophotometry. It is usually used in quatitative research of nucleic acid, proteins and bacterial concentration.

Features:

*Microscale sample test, minium 0.5ul

*Wildly test area, 100 times of the traditional spectrophotometer
*No need to dilute for most samples
*Test directly, no need to warm-up, container test and daily consumtion test
*Whole wavelength 190-1100nm, accuracy 1nm, auto scannig wavelength 190-850nm
*Compact size and partable package fitable for on-site test
*More accurate and fexiable test is realized by PC contry

Specification


Minimum Sample Size0.5ul
Wavelength Range190-850nm
Optical Distance1mm/0.2mm/0.05mm(optional)
Wavelength Accuracy1nm
Wavelength Resolution≤0.3nm(FWHM at Hg 253.7nm)
Absorbance Accuracy2%(0.76 at 257nm)
Absorbance Resolution0.002Abs(at 1mm optical distance)
Absorbance Range0.02-300A(10mm equivalent)
Detection RangeLower limit 2ng/ul (dsDNA);Upper limit 15000ng/ul (dsDNA)
Sample Pedestal Material304 Stainless Steal and Quartz
Measurement Time<5S
Detector3648CCD
Light SourceXenon flash lamp
Absorbance Test Range0.1~5Abs. ±0.1Abs 5~80Abs.±2% (can extend to 300Abs)
Dimensions (W x D x H)mm200*130*136
Weight≤2.0KG
Operating Power24W
VoltageAC100-240V;50-60Hz
Display LanguageEnglish and Chinese

Exhibition:

The Company:

The Factory:

FAQ:

1. Are you a factory or a trading company?
We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

2. What about the after-sale service?
Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer’s worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.


3. What areas and applications can it be used?
It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry,life science, petrochemical industry, mining, quality control, environmental protection, etc.

4. Why the reading is red and reach its maximum value 3.00Abs?
Probably you use the glass cuvette in UV range.

5. Why the wavelength calibration or self checking fail?
The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
6. Why is the reading is not as accurate as before?
Do the wavelength calibration before testing or restore the device to its default factory settings.