| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | LCD Digital Multimeter | 
|---|---|
| Brand Name: | CHX | 
| Model Number: | CHX-DM026 | 
| Certification: | CE, RoHS | 
| Place of Origin: | CHINA | 
| MOQ: | 10pc | 
| Price: | Negotiation | 
| Payment Terms: | T/T, Western Union,Paypal,L/C | 
| Supply Ability: | 50000pcs/month | 
| Delivery Time: | 5-35days | 
| Packaging Details: | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg | 
| Model: | CHX-DM026 | 
| Alternating current range: | 600.0uA | 
| Resolution: | 0.1uA | 
| Accuracy: | ±(1.5% of reading +10words) | 
| Overload protection: | mA range fuse (self-recovery fuse 200mA / 250V) | 
| Maximum input current: | mA: 600mA DC or AC rms; | 
AC Voltage Sine Wave True RMS Infrared Themometer Input Impedance 10MΩ
Description:
- instrument for the portable, professional measuring instruments,
with LCD digital display, and a backlight,
Users are easy to read. The range switch is easy to measure with
one hand operation, with overload protection and low battery
indication. Whether professional, factory, school, enthusiast or
family use, are an ideal
Multi-function instrument.
- instrument for AC current, DC current, AC voltage sine wave true
RMS, DC voltage, frequency, duty cycle, resistance, capacitance
measurement and line off, diode testing, temperature measurement.
- The instrument has an automatic range function.
- The meter has a reading hold function.
- The instrument has an automatic shutdown function.
Maintenance
1.4.1 Do not attempt to open the bottom case to adjust or repair
the instrument. This operation can only be performed by a
technician who is fully aware of the instrument and the risk of
electric shock.
1.4.2 Before opening the instrument case or battery cover, remove
the test leads from the circuit under test.
1.4.3 In order to avoid false alarms that may cause errors, when
the meter displays the "" symbol,Replace the battery immediately.
1.4.4 Use a damp cloth and mild detergent to clean the meter, do
not use abrasives or solvents.
1.4.5 When the instrument is not in use, turn off the power and
turn the range switch to the OFF position.
1.4.6 If the instrument is not used for a long time, remove the
battery to prevent damage to the instrument.
Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS
measurement method than the traditional average response method
error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine
wave signal, but if it is on the AC function, the instrument may
display 1 to 50 if the measured signal is not input (shorted at the
AC voltage range and the input terminal) Word between a reading.
These deviations are normal. Within the specified measuring range,
they do not affect the accuracy of the multimeter to measure
alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain
level for measurement. Therefore, the AC voltage and current range
is specified between 2% and 100% of full scale.
3.2.2 DC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.5% of reading + 5 words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(0.8% of reading + 5 words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit
under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high
sensitivity, does not affect the actual measurement results.
3.2.3 AC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.8% of reading + 3words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(1.0% of reading + 10words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit
under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high
sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.5% of reading +10words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.5% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.5 DC
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.0% of reading +5words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.0% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
3.2.6 Frequency
| Range | Resolution | Accuracy | 
| 9.999Hz | 0.001Hz | ±(1.0% of reading +3words) | 
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 0.001kHz | |
| 99.99KHZ | 0.01kHZ | |
| 999.9KHZ | 0.1KHZ | |
| 9.999MHZ | 0.001MHZ | 
- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency
increases, the input voltage should also increase)
3.2.7 Duty cycle
| Range | Resolution | Accuracy | 
| 0.1 – 99.9% | 0.1% | ± 3.0% | 
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
Resistance
| Range | Resolution | Accuracy | 
| 600W | 0.1W | ±(0.8% of reading +3words) | 
| 6kW | 0.001kW | |
| 60kW | 0.01kW | |
| 600kW | 0.1kW | |
| 6MW | 0.001MW | ±(1.2% of reading +3words) | 
| 60MW | 0.01MW | 
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
Transistor test
| Range | Description | Test Conditions | 
| hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V | 
Capacitance
| Range | Resolution | Accuracy | 
| 9.999nF | 0.001nF | ±(4.0% of reading +3words) | 
| 99.99nF | 0.01nF | |
| 999.9nF | 0.1nF | |
| 9.999mF | 0.001mF | |
| 99.99mF | 0.01mF | |
| 999.9mF | 0.1mF | |
| 9.999mF | 0.001mF | ±(5.0% of reading +3words) | 
| 99.99mF | 0.01mF | Not calibrated | 
- Overload protection: 250V DC or AC (rms)
Temperature test
| Range | Accuracy | Resolution | 
| -20℃-300℃ | ±(1.0%+4d) | 1℃ | 
| 301℃-1000℃ | ±(1.9%+5d) | 1℃ | 
| -4℉-600℉ | ±(1.2%+6d) | 1℉ | 
| 601℉-1832℉ | ±(1.9%+6d) | 1℉ | 
- Overload protection: 250V DC or AC (rms)
|   | 
 6000 Counts LCD Digital Multimeter 99.9mF 750V With Backlight Function
                                                                                    
                        
                        
                        
                                                            6000 Counts LCD Digital Multimeter 99.9mF 750V With Backlight Function
                                                    
                        
                     DC 1000V Multimeter Voltage Tester 6000 Counts LCD Display
                                                                                    
                        
                        
                        
                                                            DC 1000V Multimeter Voltage Tester 6000 Counts LCD Display
                                                    
                        
                     600kW 6MW Universal Digital Multimeter Anti Shock Protection
                                                                                    
                        
                        
                        
                                                            600kW 6MW Universal Digital Multimeter Anti Shock Protection
                                                    
                        
                     Manual range LCD Digital Multimeter 1000V 20mF 60Hz with NVC
                                                                                    
                        
                        
                        
                                                            Manual range LCD Digital Multimeter 1000V 20mF 60Hz with NVC
                                                    
                        
                     600Q 6kQ Portable Digital Display Multimeter RoHS Certified
                                                                                    
                        
                        
                        
                                                            600Q 6kQ Portable Digital Display Multimeter RoHS Certified
                                                    
                        
                     Portable LCD Digital Multimeter Professional 600kQ 6MQ 60MQ True RMS Meters
                                                                                    
                        
                        
                        
                                                            Portable LCD Digital Multimeter Professional 600kQ 6MQ 60MQ True RMS Meters
                                                    
                        
                     High Accuracy LCD Digital Multimeter 10MΩ 0.1%  99% Duty Cycle
                                                                                    
                        
                        
                        
                                                            High Accuracy LCD Digital Multimeter 10MΩ 0.1%  99% Duty Cycle
                                                    
                        
                     250V LCD Digital Multimeter Tester 10MΩ Overload protection
                                                                                    
                        
                        
                        
                                                            250V LCD Digital Multimeter Tester 10MΩ Overload protection
                                                    
                        
                     0.001V High Resolution 4000 Counts Multimeter 1000Hz True RMS NVC
                                                                                    
                        
                        
                        
                                                            0.001V High Resolution 4000 Counts Multimeter 1000Hz True RMS NVC
                                                    
                        
                     Automatic Range LCD Digital Multimeter 9.999Hz 0.001Hz Resolution
                                                                                    
                        
                        
                        
                                                            Automatic Range LCD Digital Multimeter 9.999Hz 0.001Hz Resolution