| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Digital Clamp Multimeter | 
|---|---|
| Brand Name: | CHX | 
| Model Number: | CHX-CM005 | 
| Certification: | CE, RoHS | 
| Place of Origin: | CHINA | 
| MOQ: | 10pc | 
| Price: | Negotiation | 
| Payment Terms: | T/T, Western Union,Paypal,L/C | 
| Supply Ability: | 50000pcs/month | 
| Delivery Time: | 5-35days | 
| Packaging Details: | 1pcs/gift box, 30~50pcs/ctn | 
| AC Voltage: | 6V/60V/600V | 
| Display: | LCD | 
| DC Voltage: | 2V/20V/200V/500V | 
| DC current: | 20A/100A | 
| AC Current: | 2A/20A/100A | 
| Working Temperature: | -10~50℃ | 
Automatic range Digital Clamp Multimeter 100A AC 50Hz
Descriptions
-This meter is a portable professional measuring instrument with
LCD and back light easily reading. The ‘single-hand operation’
design for the range switch makes measurement simple and easy.
Overload protection and low battery indication are provided. It is
an ideal multi-function Instrument with scores of practical
applications for professional, workshop, school, hobby and home
use.
- - used for AC current,DC current (only 220D),True RMS AC voltage
sine wave, DC voltage, frequency, duty ratio, resistance,
capacitance measurement and the continuity test, diode test,
temperature test(only 200D)and excitation voltage test.
- Automatic range
- Data hold
- auto power off
SAFETY INFORMATION
This instrument strictly follow GB/T 13978-92 Generic specification ,accordance with GB4793.1-1995(IEC-61010-1, IEC-61010-2-032)electronic measuring instruments safety requirements,Belong to the two class of pollution,Voltage standard is CAT IV 300Vand CAT III 600V.
Please Follow all safety and operating instructions to ensure safe use of the meter.
Follow all safety and operating instructions to ensure safe use of the meter.
Warning
BE EXTREMELY CAREFUL WHEN USING THIS METER. Improper use of this device can result in electric shock or destruction of the meter. Take all normal safety precautions and follow the safeguards suggested in this manual.
To exploit full functionality of the meter and ensure safe operation, please read carefully and follow the directions in this manual.
PRELIMINARY
Follow all safety and operating instructions to ensure safe use of the meter:
- General protection against electric shock
- Protection of the meter against misuse
When the meter is delivered, check whether it has been damaged in transit.
After being stored and delivered under harsh conditions, the meter should be checked and confirmed whether any damages have been incurred.
Test leads must be kept in good condition. Before using check whether the insulation on test leads has been damaged and any wire has been exposed.
Use the test leads supplied to ensure operation safety. If required, they must be replaced with test leads of the same model or class.
Technical specifications:
Environment temperature:235℃ Relative humidity:<75%
3.2.1 True RMS
3.2.1.1 For measuring non-sinusoidal waveforms, test error which is
occurred by using True RMS measurement techniques is less than by
using traditional average-reading techniques.
3.2.1.2 Both sinusoidal and non-sinusoidal waveforms can be tested
by True RMS Clamp Meter exactly. At AC A & AC V ranges, even short
two test probes there are still 1-50 digits might be displayed on
LCD. This is normal. Test result will not be affected.
3.2.1.3 At AC A and AC V range, True RMS value can be tested only
when input signal is more than 2% -100%of full range.
3.2.2 AC Current
| Range | Resolution | Accuracy | 
| 2A | 0.001A | ±(4.0% + 20) | 
| 20A | 0.01A | ±(2.5% + 8) | 
| 100A | 0.1A | 
- maximum/ input current:100A AC
- Frequency range:50Hz
3.2.3 DC CURRENT(2008D)
| Range | Resolution | Accuracy | 
| 20A | 0.01A | ±(2.5% + 10) | 
| 100A | 1A | 
- maximum/ input current:100A DC
3.2.4 DC Voltage
| Range | Resolution | Accuracy | 
| 2V | 0.001V | ±(0.8% + 5) | 
| 20V | 0.01V | |
| 200V | 0.1V | |
| 500V | 0.1V | ±(1.0% + 5) | 
- Input impedance:10MW
- Maximum/ input voltage:600V AC (Effective value)OR 600V DC
NOTICE:
At small voltage range, unsteady readings will appear before the test leads contact the circuit. This is normal because the meter is highly sensitive. When the test leads contact the circuit, the true reading will be shown.
|   | 
 High Accuracy Digital Clamp Meter Multimeter with LCD display
                                                                                    
                        
                        
                        
                                                            High Accuracy Digital Clamp Meter Multimeter with LCD display
                                                    
                        
                     Pocket Size Digital Multimeter
                                                                                    
                        
                        
                        
                                                            Pocket Size Digital Multimeter
                                                    
                        
                     340g Digital Clamp Meter Multimeter
                                                                                    
                        
                        
                        
                                                            340g Digital Clamp Meter Multimeter
                                                    
                        
                     Auto Range Digital Clamp Multimeter
                                                                                    
                        
                        
                        
                                                            Auto Range Digital Clamp Multimeter
                                                    
                        
                     10MW 20V Digital Clamp On Multimeter With NCV Zone / LCD Monitor
                                                                                    
                        
                        
                        
                                                            10MW 20V Digital Clamp On Multimeter With NCV Zone / LCD Monitor
                                                    
                        
                     60A 0.1A Digital Clamp Multimeter Auto Ranging / Manual Ranging
                                                                                    
                        
                        
                        
                                                            60A 0.1A Digital Clamp Multimeter Auto Ranging / Manual Ranging
                                                    
                        
                     0.02A AC 45Hz 65Hz Digital AC Clamp Meter / NCV Test Multimeter
                                                                                    
                        
                        
                        
                                                            0.02A AC 45Hz 65Hz Digital AC Clamp Meter / NCV Test Multimeter
                                                    
                        
                     CHX-CM010 Digital Clamp Multimeter 190g LCD Display Multimeter
                                                                                    
                        
                        
                        
                                                            CHX-CM010 Digital Clamp Multimeter 190g LCD Display Multimeter
                                                    
                        
                     LCD Display Mini Digital Clamp Meter Autormatic Range 600V
                                                                                    
                        
                        
                        
                                                            LCD Display Mini Digital Clamp Meter Autormatic Range 600V
                                                    
                        
                     Measuring Instrument Digital Clamp Multimeter 45Hz 65Hz With Liquid Crystal Display
                                                                                    
                        
                        
                        
                                                            Measuring Instrument Digital Clamp Multimeter 45Hz 65Hz With Liquid Crystal Display