| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | AC Load Bank | 
|---|---|
| Brand Name: | KAIXIANG | 
| Model Number: | 1000KW | 
| Certification: | ISO9001 | 
| Place of Origin: | HEBEI CHINA | 
| MOQ: | ONE SET | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram, D/P | 
| Supply Ability: | 20 SETS ONE MONTH | 
| Delivery Time: | ONE MONTH AFTER GET DEPOSIT | 
| Packaging Details: | WOODEN CASE | 
| Rating Voltage: | 400VAC/50Hz, 3 phase 4 wire | 
| Rated Load Power: | Resistive load: 1000kW | 
| Rated Voltage: | 400 VAC | 
| Installed Capacity: | Resistive load: 1000kW | 
| Load Tolerance(overall): | ±3% | 
| Control Power: | 380VAC/50Hz, 3 phase 4 wire, 230V 1-phase | 
1000KW AC 3 Phase Variable Resistive Dummy Load Bank for Generator
Testing
Product Description
Automatic AC load bank main used to test the capability and aging
degree for high-power ups on-line, inverter, switch power and
diesel generator set for electric power, telecom department and
manufacturer. It can ensure the reliability of constant power
charge that adopts uniformly stepped power input, energy
consumption work model and forced air-cooling model. It is of high
power density, no red hot phenomenon and automatic protection
function overheated. It can’t be overheated and broken when the
fans stop working. The complete machine can be operated simply and
maintain convenient that adopts module design. It can test voltage
and current according to client’s request, and provide scientific
test measures for high-power AC equipment.
Technical Parameters
| Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, | 
| Rated Load Power | Resistive load: 1000kW | 
| Installed Capacity | Resistive load: 1000kW | 
| Load Step | 1,2,2,5,10,20,20,50,100,200,200,200,200kW, min step load: 1kW | 
| PF(Power Factor) | 1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 380VAC/50Hz, 3 phase 4 wire, | 
| Wire Connection | Load power supply input——Copper bar (star coupling) | 
| Insulation | F | 
| Duty Cycle | Continuous | 
| Casing Dimensions and Cooling | about 1680*2400*1440mm (length*width*height) Forced air cooling,Horizontal inlet air,Horizontal outlet air | 
| Weight | About 1200kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤1500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
Product Advantage
1. Fan protection: Machine could not do load testing before working
power of fan is on.
2. The machine will unload and give alarm when any fan is abnormal
or with insufficient air volume, etc.
3. When control power cable in wrong connections, 3 phase fans can
also work in good conditions.
4. Protection button: there are some protection buttons can be
switched off when false alarm or for special requirements.
Application
1. Manufacturers of standby power generators commonly use load
banks to test and tune newly assembled units
2. generator has been set up in a test cell within the factory, a
test engineer uses the load bank to apply a discrete, selectable
electrical load to the generator and measure the response stability
and endurance.
3. During this process, the test engineer calibrates and adjusts
the generator performance to ensure it meets the intended product
specifications and tolerances.
|   | 
 Three Phase Resistive AC Load Bank Eliminate Carbon Deposition Of Generator
                                                                                    
                        
                        
                        
                                                            Three Phase Resistive AC Load Bank Eliminate Carbon Deposition Of Generator
                                                    
                        
                     Dummy AC 1000kw Resistive Load Bank Testing For Generator To 5MW ISO9001
                                                                                    
                        
                        
                        
                                                            Dummy AC 1000kw Resistive Load Bank Testing For Generator To 5MW ISO9001
                                                    
                        
                     High Power Density 3 Phase Load Bank Electrical Load Testing Equipment With Phase Voltage
                                                                                    
                        
                        
                        
                                                            High Power Density 3 Phase Load Bank Electrical Load Testing Equipment With Phase Voltage
                                                    
                        
                     3 Phase Generator Dummy Ups Load Bank Test Electrical With High Accuracy
                                                                                    
                        
                        
                        
                                                            3 Phase Generator Dummy Ups Load Bank Test Electrical With High Accuracy
                                                    
                        
                     ISO IEC CE Electronic Portable Resistive Load Bank With F Insulation
                                                                                    
                        
                        
                        
                                                            ISO IEC CE Electronic Portable Resistive Load Bank With F Insulation
                                                    
                        
                     Auto Testing Machine Usage AC 1000KW Reactive Load Bank Continuous Duty Cycle
                                                                                    
                        
                        
                        
                                                            Auto Testing Machine Usage AC 1000KW Reactive Load Bank Continuous Duty Cycle
                                                    
                        
                     Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die Generators
                                                                                    
                        
                        
                        
                                                            Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die Generators
                                                    
                        
                     Wirewound Technology Resistance AC Load Bank 1000KW For Data Center Testing
                                                                                    
                        
                        
                        
                                                            Wirewound Technology Resistance AC Load Bank 1000KW For Data Center Testing
                                                    
                        
                     High Load Power Density Generator Load Bank 500kw Grade Orange Testing UPS
                                                                                    
                        
                        
                        
                                                            High Load Power Density Generator Load Bank 500kw Grade Orange Testing UPS
                                                    
                        
                     High Accuracy Electrical Generator Resistive Load Tester 100kw Power
                                                                                    
                        
                        
                        
                                                            High Accuracy Electrical Generator Resistive Load Tester 100kw Power