| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Electrical Load Bank | 
|---|---|
| Brand Name: | KAIXIANG | 
| Model Number: | AC400-1500KW | 
| Certification: | ISO9001 | 
| Place of Origin: | HEBEI CHINA | 
| MOQ: | ONE SET | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 20 SETS ONE MONTH | 
| Delivery Time: | ONE MONTH AFTER GET DEPOSIT | 
| Packaging Details: | WOODEN CASE | 
| Resistive load: | 1500KW | 
| Load Tolerance: | ±3% | 
| Control Power: | 380VAC/50Hz, 3 phase 4 line | 
| Insulation: | F | 
| Altitude: | ≤1500 meter | 
| Color: | grey | 
Auto Testing Machine Usage 1500KW Load Bank 3 Phase 4 Wire With F
Insulation
Product Description
The machine has its own cooling system, when temperature of the
machine is too high that it unload automatically. The equipment
used to test the output power and loading capacity of High Voltage
Generator. The load bank power input adopts sectional type, with
remote control, easy to operation.Load bank using energy
consumption method, air forced cooling, air dispersion, so that
machine noise reduces greatly.
Technical Parameter
| Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, | 
| Rated Load Power | Resistive load: 500kW | 
| Installed Capacity | Resistive load: 500kW | 
| Load Step | 1,2,2,5,10,10,20,50,100,100,200kW | 
| PF(Power Factor) | 1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 380VAC/50Hz, 3 phase 4 wire, | 
| Wire Connection | Load power supply input——Copper bar (star coupling) | 
| Insulation | F | 
| Protection Grade | IP21 | 
| Way of Working | Continuous Working | 
| Casing Dimensions and Cooling | about 1550*1250*1680mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 750kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤1500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
Product Advantage
The data processing software is installed in the notebook or PC,
customer can connect computer and load bank by data transmission
line, and then realize all the test function by intelligent control
through the software
Application
Load Banks are used with Engine Generators, Battery Systems, UPS
Systems, Inverters, Ground Power Units, Auxiliary Power Units,
Aircraft Power Generators, Wind Generators, and Hydro Generators.
It is used with Engine Generators, Battery Systems, UPS Systems,
Inverters, Ground Power Units, Auxiliary Power Units, Aircraft
Power Generators, Wind Generators, and Hydro Generators.
|   | 
 Automatic Electrical Load Bank Intelligent Orange With Manual Control Panel
                                                                                    
                        
                        
                        
                                                            Automatic Electrical Load Bank Intelligent Orange With Manual Control Panel
                                                    
                        
                     Automatic 2000 KW Electrical Load Bank , Continuous Working AC Load Bank
                                                                                    
                        
                        
                        
                                                            Automatic 2000 KW Electrical Load Bank , Continuous Working AC Load Bank
                                                    
                        
                     Large Gray 3 Phase Load Bank 2100 KW Line Voltage 400 V With Hydro Generators
                                                                                    
                        
                        
                        
                                                            Large Gray 3 Phase Load Bank 2100 KW Line Voltage 400 V With Hydro Generators
                                                    
                        
                     Over Heat Protection Variable Resistive Load Bank With Phase Voltage 230 V
                                                                                    
                        
                        
                        
                                                            Over Heat Protection Variable Resistive Load Bank With Phase Voltage 230 V
                                                    
                        
                     2400 KW Electrical Load Bank , Resistive Load Bank For Storage Battery Systems
                                                                                    
                        
                        
                        
                                                            2400 KW Electrical Load Bank , Resistive Load Bank For Storage Battery Systems
                                                    
                        
                     2500 KW Electrical Load Bank Over Heat Protection With Fan Cooling System
                                                                                    
                        
                        
                        
                                                            2500 KW Electrical Load Bank Over Heat Protection With Fan Cooling System
                                                    
                        
                     Safety Monitoring Variable Resistive Load Bank Continuous Working For Generator
                                                                                    
                        
                        
                        
                                                            Safety Monitoring Variable Resistive Load Bank Continuous Working For Generator
                                                    
                        
                     4510 KW High Capacity Electrical Load Bank , 60 HZ Resistive Load Bank
                                                                                    
                        
                        
                        
                                                            4510 KW High Capacity Electrical Load Bank , 60 HZ Resistive Load Bank
                                                    
                        
                     Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator
                                                                                    
                        
                        
                        
                                                            Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator
                                                    
                        
                     Ocean Engineering Dummy Load Bank Automatic 400 V With Alloy Resistance
                                                                                    
                        
                        
                        
                                                            Ocean Engineering Dummy Load Bank Automatic 400 V With Alloy Resistance