| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Tilt Sensor Inclinometer |
|---|---|
| Brand Name: | Rion |
| Model Number: | ACA6-MB |
| Certification: | CE, ISO |
| Place of Origin: | Guangdong, China |
| MOQ: | 1 |
| Price: | $680.00/Pieces >=1 Pieces |
| Payment Terms: | T/T,Paypal |
| Supply Ability: | 3000 Piece/Pieces per Month |
| Delivery Time: | 7 days for samples |
| Packaging Details: | 1pcs/box with sponge inside, 100pcs/ctn |
| Resolution: | 0.001° |
| Measure axis: | X/XY |
| Measure accuracy: | 0.003~0.3°(RMS) |
| Response frequency: | 20Hz |
| Communication protocol: | RION 68 protocol / MODBUS protocol |
| Output signal: | RS232 / RS485 / RS422 / TTL |
| Output rate: | 5Hz / 15Hz / 35Hz / 50Hz can be setting |
| Power supply: | 9~36v |
| Company Info. |
| Shenzhen Rion Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
ACA6 HIGH ACCURACY DIGITAL TYPE MODBUS TILT SENSOR WITH FULL TEMP-COMPENSATION
ACA616T/ACA626T is a high-precision, full-temperature-compensated single/dual-axis tilt sensor with MODBUS digital output, developed by RION Technology based on an advanced precision tilt platform. Featuring excellent temperature stability, it operates reliably in wide temperature ranges from -40℃ to 85℃, making it ideal for long-term outdoor equipment monitoring and leveling.
Key Features:
Built-in high-precision 24-bit differential A/D converter;
Fifth-order filtering algorithm ensures precise measurement of tilt and pitch angles relative to horizontal;
Available with RS485, RS232, or TTL output interfaces for flexible system integration;
Non-contact installation design—simply mount the sensor on the object's surface with screws, no alignment required;
Strong resistance to electromagnetic interference, shock, and vibration;
Offers a significant competitive edge among domestic peers, tailored for high-end industrial applications.
▶ MAIN FEATURES
★ Single / dual axis inclination measurement ★ Wide voltage input: 9~36V
★ Measure Range :±90° optional ★ IP67 protection grade
★ Wide temperature working: -40~+85℃ ★ Resolution: 0.001°
★ Highly anti-vibration performance >2000g ★ Water-proof air-plug
★ Output mode RS232/RS485/RS422/TTL are optional ★ Size: 92×48×36mm
▶ APPLICATION FIELD
★ Engineering vehicles automatic leveling ★ Bridge & dam detection
★ Laser equipment position ★ Medical facilities angle control
★ Underground drill posture navigation ★ Precise machine tool level control
★ Geological equipment inclined monitoring
★ Railway gauging rule , gauge equipment leveling
▶ SPECIFICATIONS
|
| Conditions | Parameters | Unit | |||
| Measure range |
| ±10 | ±30 | ±60 | ±90 | ° |
| Measure axis |
| X/XY | X/XY | X/XY | X/XY | AXIS |
| Resolution |
| 0.001 | 0.001 | 0.001 | 0.001 | ° |
| Measure accuracy | @25℃ | 0.003 | 0.01 | 0.02 | 0.03 | °(RMS) |
| Zero Temp. coefficient | -40~+85℃ | ±0.0004 | ±0.0004 | ±0.0004 | ±0.0004 | °/℃ |
| Sensitivity temp-coeffi | -40~+85℃ | ≤50 | ≤50 | ≤50 | ≤100 | ppm/℃ |
| Power on time |
| 0.5 | 0.5 | 0.5 | 0.5 | S |
| Response frequency | 20Hz | |||||
| Output rate | 5Hz / 15Hz / 35Hz / 50Hz can be setting | |||||
| output signal | RS232 / RS485 / RS422 / TTL | |||||
| Communication protocol | RION 68 protocol / MODBUS protocol | |||||
| EMC | According to EN61000 and GBT17626 | |||||
| MTBF | ≥98000 hours/times | |||||
| Insulation Resistance | ≥100MΩ | |||||
| Shockproof | 100g@11ms / 3 Axial Direction (Half Sinusoid) | |||||
| Anti-vibration | 10grms / 10~1000Hz | |||||
| Protection grade | IP67 | |||||
| Cables | Standard 2m long, wear-resistant, wide temperature, shielded cable 5p * 5.7 mm aviation connector | |||||
| Weight | ≤220g(without cable) | |||||
▶ WORKING PRINCIPLE
Adopt imported core control unit and apply the principle of capacitive micro-pendulum. Using the principle of earth's gravity, when the tilting unit tilts, the earth's gravity will produce a gravitational component on the corresponding pendulum, and the corresponding electric capacity will change. By amplifying and filtering the electric capacity, the inclination is obtained after conversion.



|