| Sign In | Join Free | My entremaqueros.com |
|
| Categories | IEC Test Equipment |
|---|---|
| Brand Name: | KINGPO |
| MOQ: | 1 |
| Certification: | calibration certificate |
| Place of Origin: | China |
| Price: | To be quoted |
| Payment Terms: | T/T |
| Supply Ability: | 10 sets per month |
| Delivery Time: | 25 working days |
| Packaging Details: | safety wooden box |
| standard: | IEC60884 Figure 27 |
| Falling height: | 10~250mm |
| test sample: | cable |
| falling weight mass: | (1000 ± 2) g |
| Type: | Low Temperature Impact Test Equipment |
| Company Info. |
| Dongguan Kingpo Technology Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC60884 Figure 27 IEC Test Equipment For Low Temperature Impact
IEC60884 Figure 27 Low Temperature Impact Test Equipment
Low Temperature Pressure Impact Test Equipment IEC60884 Figure 27
Product information:
The specimens are subjected to an impact test by means of an
apparatus as shown in figure 27.
The apparatus, positioned on a pad of sponge rubber 40 mm thick, is
placed together with the specimens in a freezer at a temperature of
(–15 ± 2) °C, for at least 16 h.
At the end of this period, each specimen, in turn, is placed in the
normal position of use as shown in figure 27, and a weight is
allowed to fall from a height of 100 mm. The mass of the falling
weight is (1 000 ± 2) g.
After the test, the specimen shall show no damage within the
meaning of this standard.
Technical parameters:
The height of falling: 10~250mm is adjustable.
| Low-temperature impact test sample | Standard | Weight of the drop hammer (g) | The height of the impact mm | Remark |
| The socket box and the similar electrical enclosure | GB2099.1-2008 clause24.4, figure 27 | 1000±2 | 100 | standard |
| The bolt with insulation sheath | GB2099.1-2008 clause30.4, figure 42 | 100±1 | 100 | standard |
| The electric cable with PVC sheath | GB2951.4 clause8.5,figure 2 | 100,200,300,400, 500,600,750,1000,1250,1500g | 100 | Optional |
For the samples of laying of cable, the weight of the drop hammer required are as follows:
| The external diameter of the samples(D/mm) | The weight of the drop hammer /g |
| D≤4.0 | 100 |
| 4.0<D≤6.0 | 200 |
| 6.0<D≤9.0 | 300 |
| 9.0<D≤12.5 | 400 |
| 12.5<D≤20.0 | 500 |
| 20.0<D≤30.0 | 750 |
| 30.0<D≤50.0 | 1000 |
| 50.0<D≤75.0 | 1250 |
| 75.0<D | 1500 |
For the samples of flexible cable and telecommunication cable, the weight of the drop hammer required is as follows:
| The external diameter of the sample D/mm | The weight of drop hammer /g |
| D≤6 | 100 |
| 6.0<D≤10.0 | 200 |
| 10.0<D≤15.0 | 300 |
| 15.0<D≤25.0 | 400 |
| 25.0<D≤35.0 | 500 |
| 35.0<D | 600 |


|