| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Surge Protection Device SPD |
|---|---|
| Brand Name: | Uchi |
| Model Number: | OBV10-I-15 |
| Certification: | CE / SGS / ISO9001 |
| Place of Origin: | Dongguan China |
| MOQ: | 200 piece |
| Price: | Negotiate |
| Payment Terms: | T/T, L/C, Western Union |
| Supply Ability: | 60000 pieces per month |
| Delivery Time: | 5-15 days after payment |
| Packaging Details: | export package / Negotiate |
| Name: | Surge Protection Device |
| Poles Number: | 1P,2P,3P,4P,(+NPE) |
| Uc: | 255/275/320/385VAC |
| In: | 60KA |
| Imax: | 100KA |
| Response time: | <25ns |
| Limp: | 15KA |
| Temperature range: | -40℃~+85℃ |
| CertificationCE,CQC: | CE / CQC / SGS |
| Connections: | TT/TN |
| Protection modes: | L/N |
| Company Info. |
| Guangdong Uchi Electronics Co.,Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
OBV10-I-15
Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.
Technical Parameters
| Model: OBV10-I-15-Pluggable | |||
| Maximum continuous operating voltage | Uc | V | 255/275/320/385 |
| SPD to EN 61643-11 | Type 1 | ||
| SPD to IEC 61643-1 | class I | ||
| LPZ | 0→2 | ||
| Lightning impulse current (10/350μs) | Iimp | kA | 15 |
| Lightning impulse current (10/350μs) [total] | kA | 60 | |
| Nominal discharge surge current (8/20μs) | In | kA | 60 |
| Maximum discharge surge current (8/20μs) | Imax | kA | 100 |
| Voltage protection level | Up | kV | 2,5 |
| Response time | tA | ns | <25 |
| Follow current quenching capacity Ipeak | Ifi peak | kA | 12.5 |
| Maximum back-up fuse | A | 315 | |
| Temperature range | ϑ | °C | -40℃~+85℃ |
| Protection rating | IP 20 | ||
| Connection cross-section, rigid | mm² | 10-50 | |
| Connection cross-section, multi-wire | mm² | 10-35 | |
| Connection cross-section, flexible | mm² | 10-25 | |
Feature
• Easy to install in any standardized distribution pane or control cabinets.
Application
● These devices protect low-voltage consumer systems from
overvoltage.
● Applied in modular SPD Class I + Class II (Class B + C) for TT
and TN-S power supply system.
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
| Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
| DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
| DGM1(2)-D10 | 10 | 2 | 1.6 | |||
| DGM1(2)-C20 | 20 | 40 | 1.8 | |||
| DGM13-B30 | 30 | 60 | .2.2 | |||
| DGM3(4)-B40 | 10 | 80 | 2.4 | |||
| DGM(4)-B60 | 60 | 100 | 2.8 | |||
| DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Tip:How can we distinguish the quality of the lightning arrester?
1. It can be seen from the reaction time: determine whether the
lightning arrester can respond in time and quickly discharge the
lightning current.
2. It can be seen from the insertion loss: this refers to the
installation of a lightning protector, the impact of this lightning
protector on the line, the smaller the better
3. It can be seen from the number of impact resistance: determines
the service life of the lightning arrester. Generally, the gas
discharge tube will not drop after being placed for a period of
time. If you want to check its quality, you can use an adjustable
high-voltage DC power supply to test .
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?