Sign In | Join Free | My entremaqueros.com |
|
Categories | Intelligent Pressure Transmitter |
---|---|
Brand Name: | CHONGQING CHUANYI, SICC |
Model Number: | PDS803, PDS863 |
Certification: | CE, SIL, ATEX, HART, IECEx, CSS, ISO9001, ISO14001, ISO45001 |
Place of Origin: | CHONGQING,CHINA |
MOQ: | 1 SET |
Price: | Negotiated Pricing |
Payment Terms: | L/C, D/A, D/P, T/T |
Supply Ability: | As Appropriate |
Delivery Time: | As Appropriate |
Packaging Details: | Strong Export Packing |
Product Name: | PDS Intelligent Pressure Hygienic Pressure Paper Pressure Transmitter |
Seismic Rating: | Seismic Class I |
Measuring Range: | 0-50pa~70Mpa |
Accuracy: | ±0.04% (Up To ±0.025%) |
Long-Term Stability: | ≤±0.1%/10 Years |
Fast Response: | ≤ 90ms (50ms Data Refresh Time) |
Range Ratio: | 100:1 |
Explosion Protection Certification: | Ex Iaiict4\T6 Ga, Ex Diict6 Gb |
Non-Ex NEPSI: | Intrinsically Safe Ex Ia ⅡCT4 Ga |
NEPSI: | Dust Ex Ex Td A21 IP67 T85°C |
Safety Certification: | SIL2 |
Communication Protocols: | HART, Profibus-PA, FF, Wireless Hart, Zigbee |
PDS Intelligent Pressure Transmitter
Main Technical Parameters:
Seismic Rating: Seismic Class I
Measuring Range: 0-50pa~70Mpa
Accuracy: ±0.04% (Up To ±0.025%)
Long-Term Stability: ≤±0.1%/10 Years
Fast Response: ≤ 90ms (50ms Data Refresh Time)
Range Ratio: 100:1
Explosion Protection Certification: Ex Iaiict4T6 Ga, Ex Diict6 Gb
Non-Ex NEPSI: Intrinsically Safe Ex Ia ⅡCT4 Ga
NEPSI: Intrinsically Safe Ex Ia ⅡCT6 Ga
NEPSI: Explosion-Proof Ex D ⅡCT6 Gb
NEPSI: Dust Ex Ex Td A21 IP67 T85°C
ATEX: Intrinsically Safe II 1 G Ex Ia IIC T4 Ga,
ATEX: Explosion-Proof II 1/2 G Ex Db IIC T6.... .T4 Ga/Gb
Iecex: Intrinsically Safe Ex Ia IIC T4 Ga
Iecex: Ex Db IIC T6.... .T4 Ga/Gb
NEPSI: Type "N" Ex Na ⅡC T6 Gc
Overload Limit: 42mpa
Safety Certification: SIL2
Communication Protocols: HART, Profibus-PA, FF, Wireless Hart, Zigbee
15 Local Machine Configurations And Intelligent Self-Diagnosis, Simulation And Monitoring Functions
PDS Paper Pressure Transmitter
Main Technical Parameters:
Maximum range ratio r (r = maximum range / range used) = 30:1
Long-term stability: δ≤±0.1FS%/10 years
Seismic rating: Seismic Class I
Measuring range: 0-50pa~70Mpa
Accuracy: ±0.04% (up to ±0.025%)
Long-term stability: ≤±0.1%/10 years
Fast response: ≤ 90ms (50ms data refresh time)
Range ratio: 100:1
Explosion protection certification: Ex iaIICT4T6 Ga, Ex dIICT6 Gb
Non-Ex NEPSI: Intrinsically safe Ex ia ⅡCT4 Ga
NEPSI: Intrinsically safe Ex ia ⅡCT6 Ga
NEPSI: Ex d ⅡCT6 Gb
NEPSI: Dust explosion-proof Ex tD A21 IP67 T85°C
ATEX: Intrinsically safe II 1 G Ex ia IIC T4 Ga,
ATEX: Ex II 1/2 G Ex db IIC T6.... .T4 Ga/Gb
IECEx: Intrinsically safe Ex ia IIC T4 Ga
IECEx: Ex db IIC T6.... .T4 Ga/Gb
NEPSI: Type "n" Ex nA ⅡC T6 Gc
Safety certification: SIL2
PDS Hygienic Pressure Transmitter
Main Technical Parameters:
Maximum range ratio r (r=maximum range/use range) =30:1
Long-term stability: δ≤±0.1FS%/10 years
Seismic class: Seismic class I
Measuring range: 0-50pa~70Mpa
Accuracy: ±0.04% (maximum ±0.025%)
Long-term stability: ≤±0.1%/10 years
Fast response: ≤90ms (50ms data refresh time)
Range ratio: 100:1
Ex certification: Ex iaIICT4T6 Ga, Ex dIICT6 Gb
Non-Ex NEPSI: Intrinsically safe Ex ia ⅡCT4 Ga
NEPSI: Intrinsically safe Ex ia ⅡCT6 Ga
NEPSI: Explosion-proof Ex d ⅡCT6 Gb
NEPSI: Dust explosion-proof Ex tD A21 IP67 T85°C
ATEX: Intrinsically safe II 1 G Ex ia IIC T4 Ga,
ATEX: Ex II 1/2 G Ex db IIC T6.... .T4 Ga/Gb
IECEx: Intrinsically safe Ex ia IIC T4 Ga
IECEx: Ex db IIC T6.... .T4 Ga/Gb
NEPSI: Type "n" Ex nA ⅡC T6 Gc
Safety certification: SIL2
![]() |