| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | CT PT Test Equipment | 
|---|---|
| Brand Name: | HNMC | 
| Model Number: | FYC series | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 30 sets per month | 
| Delivery Time: | 30-45 days | 
| Packaging Details: | Wooden Package | 
| Rated Current: | 1A, 5A | 
| Power factor: | 0.8, 1.0 | 
| Accuracy class: | 3 | 
| Rated Frequency: | 50/60 HZ | 
| Rated voltage: | 110V, 100V, 110V/√3V, 100V/√3V | 
| Insulation: | Air | 
Manual or Automatic CT VT Burden box FYC series
FYC47-49 CT Burden
Technical Parameter
| Rated Current: | 5A, 1A | 
| Power Factor and Rated Burden: | COSΦ=0.8: 5VA, 10VA, 15VA, 20VA, 30VA COSΦ=1.0: 1VA, 2VA, 5VA | 
| Accuracy Class: | ±3% | 
| Operation Range: | (1%-200%). In | 
| Test Cable Resistance: | 0.02Ω | 
| Frequency: | 50Hz | 
| Withstand Voltage: | 2kV/1min | 
| Insulation: | Air | 
| Operating Mode: | Continue at 200%.In | 
| Control Mode: | Manual and computer controllable (protocol provided) | 
| Cooling Mode: | Fan | 
FYC95 PT Burden
Technical Parameters
| Rated Voltage: | 110V, 100V, 110V/√3V, 100V/√3V | 
| Power Factor and Rated Burden: | COSФ=0.8: 10VA, 25VA, 50VA, 100VA (Total burden:185VA) COSФ=1.0: 1VA, 2.5VA, 5VA, 10VA (Total burden:18.5VA) | 
| Accuracy Class: | ±3% | 
| Operation Range: | (20%-190%). Un | 
| Frequency: | 50Hz | 
| Withstand Voltage: | 2kV/1min | 
| Insulation: | Air | 
| Operating Mode: | Continue at 190%.Un | 
| Control Mode: | Manual and computer controllable (protocol provided) | 
| Cooling Mode: | Fan | 
Technical service
Much experienced technical team will provide strong technical support for your market development. We can provide support on customization, maintenance, device design, construction scheme, design optimization, and product development.
Quality control
We have professional quality control team. Our quality control covers materials, production procedure, finished product inspection, final inspection before loading, inspection report.
|   | 
 CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                                                    
                        
                        
                        
                                                            CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                    
                        
                     Cabinet Type CT PT Test Equipment System Error Measurement
                                                                                    
                        
                        
                        
                                                            Cabinet Type CT PT Test Equipment System Error Measurement
                                                    
                        
                     0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                                                    
                        
                        
                        
                                                            0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                    
                        
                     0.02 Class  CT PT Test Equipment , Low Current CT Test Kit
                                                                                    
                        
                        
                        
                                                            0.02 Class  CT PT Test Equipment , Low Current CT Test Kit
                                                    
                        
                     4000A Current Transformer Tester In Magnetic Environment
                                                                                    
                        
                        
                        
                                                            4000A Current Transformer Tester In Magnetic Environment
                                                    
                        
                     0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                                                    
                        
                        
                        
                                                            0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                    
                        
                     0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                                                    
                        
                        
                        
                                                            0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                    
                        
                     0.02 Class CT PT Test Equipment
                                                                                    
                        
                        
                        
                                                            0.02 Class CT PT Test Equipment
                                                    
                        
                     0.05S CT PT Analyzer
                                                                                    
                        
                        
                        
                                                            0.05S CT PT Analyzer
                                                    
                        
                     Phase Angle Error CT PT Test Set
                                                                                    
                        
                        
                        
                                                            Phase Angle Error CT PT Test Set