| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | AC Resonant Test System | 
|---|---|
| Brand Name: | Fanke High-voltage | 
| Model Number: | CHX-270KVA/45KV,270KV | 
| Certification: | ISO9001 | 
| Place of Origin: | China | 
| MOQ: | One unit | 
| Price: | Negotiable | 
| Payment Terms: | T/T | 
| Supply Ability: | 10units/2months | 
| Delivery Time: | 25~45 Work Days | 
| Packaging Details: | Export Standard Wooden Case With Fumigation Free | 
| Test principle: | Variable frequency resonant circuit | 
| Test Item: | AC withstand voltage test under 45KV , 270KV | 
| Max.capacity: | 270KVA | 
| Design feature: | Portable Type , Lighter Single Piece Weight, Special for On-site Installation and test | 
| Component:: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider | 
| Test frequency: | 30-300Hz | 
| Duty cycle: | 60 mints | 
| Test accuracy: | No less than 1.5% | 
| Test object: | 35KV/10KV short cable , 110KV power substation | 
| Test standard: | IEC 60060-1:2010;IEC 62271-203:2011 for GIS, IEC 60840:2011 for XLPE cable; | 
| Product name: | ac resonant test system | 
| Certificate: | ISO9001 | 
AC Resonant Test System for 35KV Cable and 110KV Power Substation Test
Features:
I. Product Usage :
This test set model CHX-270KVA/45KV, 270KV is designed for 10KV / 35KV class short XLPE cable ,power transformer, CB,CT/PT, busbar in 110KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 45KV ,90KV,270KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test
Test range of the set is as following:transformer
1. 1000m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 5min.
2, 3000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.
3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.
4, 110kV/50000kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 160kV, test time 1min.
4, CB,CT/PT, busbar in 110KV power substation , test frequency 40-300Hz, test voltage no more than 265, test time 1min.
The whole test set consists of variable frequency power source , excitation transformer , 6pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV or 110KV power sub-station
II. General Technical Data
III. Main Components:
| SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension | 
| 1 | Variable frequency power | FKVF-20kW/380V | 1piece | 35kgs | 480*480*520mm | 
| 2 | Excitation transformer | CQSB(J)-15kVA/2.5KV,10KV | 1piece | 130kgs | 500*500*580mm | 
| 3 | HV resonant test reactor | CHX(kf)-45kVA/45kV | 6pieces | 55kgs | D420*H480mm | 
| 4 | Capacitive divider | TRF-270kV/1000pF | 1set | 30kgs | D200*H2150mm | 
| 5 | Special test accessories | 1set | 
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm
)
V. Main Measuring and control software panel:
Note: This is the software panel before start test for parameter
setting
VI.Accessories
VII. Other Optional Model
1. For GIS on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-135KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS | 
| CHX-270KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS | 
| CHX-216KVA/216KV | 27KV*8 | 1A | 216KVA | For 123KV and below GIS | 
| CHX-270KVA/270KV | 27KV*10 | 1A | 270KVA | For 145KV and below GIS | 
| CHX-275KVA/275KV | 275KV | 2A | 275KVA | For 170KV and below GIS | 
| Special requirement can be made by order | ||||
2. For 45KV XLPE cable on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Max Application | 
| CHX-108/54 | 54KV | 2A | 108KVA | 45kV cable≤1km | 
| CHX-216/54 | 54KV | 4A | 216KVA | 45kV cable≤2km | 
| CHX-324/54 | 54KV | 6A | 324KVA | 45kV cable≤3km | 
| CHX-432/54 | 54KV | 8A | 432KVA | 45kV cable≤4km | 
| CHX-540/54 | 54KV | 10A | 540KVA | 45kV cable≤5km | 
| CHX-1080/54 | 54KV | 20A | 1080KVA | 45kV cable≤10km | 
| Special requirement can be made by order | ||||
3. For 66KV XLPE cable on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Max Application | 
| CHX-160/80 | 80KV | 2A | 160KVA | 66kV cable≤0.5km | 
| CHX-320/80 | 80KV | 4A | 320KVA | 66kV cable≤1km | 
| CHX-640/80 | 80KV | 8A | 640KVA | 66kV cable≤2km | 
| CHX-960/80 | 80KV | 12A | 960KVA | 66kV cable≤3km | 
| CHX-1280/80 | 80KV | 16A | 1280KVA | 66kV cable≤4km | 
| CHX-1600/80 | 80KV | 20A | 1600KVA | 66kV cable≤5km | 
| CHX-3200/80 | 80KV | 40A | 3200KVA | 66kV cable≤10km | 
| CHX-9600/80 | 80KV | 120A | 9600KVA | 66kV cable≤20km | 
| Special requirement can be made by order | ||||
VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

|   | 
 High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test
                                                                                    
                        
                        
                        
                                                            High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation Test
                                                    
                        
                     810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30-300Hz
                                                                                    
                        
                        
                        
                                                            810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30-300Hz
                                                    
                        
                     45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test
                                                                                    
                        
                        
                        
                                                            45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test
                                                    
                        
                     132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                                                    
                        
                        
                        
                                                            132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                    
                        
                     FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity Optional
                                                                                    
                        
                        
                        
                                                            FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity Optional
                                                    
                        
                     High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low Noise
                                                                                    
                        
                        
                        
                                                            High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low Noise
                                                    
                        
                     30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                                                    
                        
                        
                        
                                                            30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                    
                        
                     Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                                                    
                        
                        
                        
                                                            Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                    
                        
                     380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                                                    
                        
                        
                        
                                                            380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                    
                        
                     Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS
                                                                                    
                        
                        
                        
                                                            Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS