IEC 62560 Test Equipment,Testing And Measuring Equipment/Allowed Subcontracting IEC 62560 Edition 1 2011 – A1:2015
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 62560 Edition 1 2011 – A1:2015
Self-ballasted LED lamps for general lighting services by voltage > 50 V - Safety specifications
“R” Required
“S” May be subcontracted, see OD 2012
“SF” Specialized Facility, see IECEE 02-2
“W” Witness testing in the categories “MED” and “MEAS”
“3PPS” Three Phase Power Supply required
| Clause | Measurement/testing | Testing / measuring equipment / material needed | Price (RMB) | Subcontracting |
| 5.3 | Marking | Hexane, | R | |
| water, | ||||
| piece of cloth | ||||
| 6.1 | Cap interchangeability - Table 1 | Gauges according to IEC 60061-1 and IEC 60061-3 | R | |
| 6.2 | Bending moment and mass imparted by the lamp at the lamp holder | Test finger with indicating device and with force meter, | R | |
| Weighting device | ||||
| 7 | Protection against accidental contact with live parts | Standard Test finger (IEC 60529) , | R | |
| IEC 60061-3, sheet 7006-51A for E27 caps | ||||
| IEC 60061-3, sheet 7006-55 for E14 caps | ||||
| Mega ohmmeter, | ||||
| High Voltage transformer | ||||
| 8.2 - 8.3 | Insulation resistance and electric strength after humidity treatment | Humidity cabinet, | R | |
| Mega ohmmeter, | Use same as Clause 7 | |||
| High Voltage transformer | Use same as Clause 7 | |||
| 9.2.1 | Torsion resistance of unused lamps | Holder for torque test Figure 3 and figure 4 | R | |
| 9.4 | Axial strength of Edison Caps | Gauges according table 4, | R | |
| dynamometer | ||||
| 10 | Cap temperature rise | Temperature test cap | R | |
| Temperature test draught-proof enclosure | ||||
| 11 | Resistance to heat | Heating cabinet, | R | |
| Ball pressure test apparatus | ||||
| 12 | Resistance to flame and ignition | Needle flame test apparatus, | R | |
| Glow-wire test apparatus | ||||
| 14 | Creepage distances and clearances | Digital calliper (or equivalent) | R | |
| 15 | Abnormal operation | Circuit shown in Figure 8 (for non-dimmable lamps on a dimmer or an electronic switch), | R | |
| test finger | ||||
| 17 | Photobiological safety | UV radiation test instruments / retinal blue light hazard test instruments (Equipment List of IEC/TR 62778:2012, Edition 1.0), | S | |
| Goniophotometric measurement system | ||||
| 18 | Ingress protection | IP X4 test equipment | R |

|