| Brand Name: | HongCe |
| Model Number: | HCWHEF01 |
| Certification: | calibration certificate (cost additional) |
| Place of Origin: | China |
| MOQ: | 1 set |
| Price: | Negotiatable |
| Payment Terms: | T/T |
| Supply Ability: | 1 set /month |
| Delivery Time: | 45 days |
| Packaging Details: | plywood |
| Product name: | Electric Water Heater Performance Test Lab |
| Power supply: | 220V 50Hz |
| Standard: | IEC 60379 |
| application: | perform the performance characteristics of electric storage water-heaters |
| usage: | Measuring Energy Efficiency |
| relative air-humidity: | not exceeding 85% |
| ambient temperature: | θamb of 20 ± 2 °C |
| Water temperature fluctuation: | θC of 15 ± 2 °C |
| Company Info. |
| Guangzhou HongCe Equipment Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Energy Efficiency Test Appliance Performance Test Lab For Storage Water Heater
Standard:
IEC 60379 Methods for measuring the performance of electric storage water-heaters for household purposes.
Application:
This system is to perform the performance characteristics of electric storage water-heaters which are of interest to the user and to describe the standard methods for measuring these characteristics. Appliance Performance Test Lab
The performance of water-heaters is determined by the following measurements:
verification of rated capacity; standing loss per 24; hot-water output; deviation of dial-calibration; cyclic variation (differential).
Feature:
Measurements are carried out on the water-heater, operating:
— in a substantially draught-free room;
— at an ambient temperature, θamb of 20 ± 2 °C.
— at a relative air-humidity not exceeding 85%.
— at rated input.
— at rated frequency, if applicable;
— mounted as described in Clause 9, supplied with water at a temperature θC of 15 ± 2 °C and provided from a source having a substantially steady pressure and installed according to the manufacturer's instructions;
— at a thermostat-setting as described in Clause 11.
Parameter:
| Test room size | 6000*4000*2600mm |
| Test room temperature | 20 ± 2 °C |
| Test room humidity | <85% |
| Sample mounting bracket | 2PCS |
| Test station | 6 stations |
| Water tank | 2PCS. Appliance Performance Test Lab |

|