Portable PR9112 ±0.05%F.S Automatic Pressure Calibrator

Categories Digital Pressure Calibrators
Brand Name: PANRAN
Model Number: PR9112
Certification: CE,ISO9001
Place of Origin: Tai’an,China
MOQ: 1 pcs
Price: negotiable
Payment Terms: TT, LC, Visa, Western Union, Alipay, Trade assurance, E-checking
Supply Ability: 30 pcs/month
Delivery Time: 10~25 working days
Packaging Details: Standard export Packing (aluminium alloy, laminated wood, carton)
Measurement Range: (-0.1~250)Mpa
Display accuracy: ±0.05%F.S,±0.02%F.S
Battery Operating Time: 60 hours (24V with no load)
Charging time: About 4 hours
Size: 115mm×45mm×180mm
Communication interface: specialized three-core aviation plug
Weight: 0.8KG
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Portable PR9112 ±0.05%F.S Automatic Pressure Calibrator

Standard Digital Pressure Calibrators With HART Communication Capability,With Uncertainty Better Than 0.02%FS


New-type products (HART agreement can be brought), Double-row liquid crystal display with backlight, There are nine pressure units can be switched according to the actual needs of users, with DC24V output function, Connect with various stressors and very suitable for field and laboratory use.


Main Application:

1.Calibrate pressure (differential pressure) transmitter

2.Calibrate pressure switch

3.Verify the precision pressure gauge, General pressure gauge.


Product Feature:

1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)

2.Double-row liquid crystal display with backlight.

3.mmH2O,mmHg,psi,kPa,MPa,Pa,mbar,bar,kgf/c㎡, switch between nine pressure units.

4.With DC24V output function.

5.With current, voltage measurement.

6.Measuring with switching volume.

7.With communication interface.(optional)


Technical Parameters

ModelPR9112 Intelligent Pressure Calibrator
Pressure MeasurementMeasurement Range(-0.1~250)Mpa
Display accuracy±0.05%F.S,±0.02%F.S

Electric Current Measurement

Range±30.0000mA
Sensitivity0.1uA
Accuracy±(0.01%R.D+0.003%F.S)

Voltage Measurement

Range±30.0000V
Sensitivity0.1mV
Accuracy±(0.01%R.D +0.003%F.S)
Switching ValueA group of Power/outage measurement
Output functionDirect-current outputDC24V±0.5V

Operating Environmental

Working Temperature(-20~50)°C
Relative Temperature<95%
Storage Temperature(-30~80)°C

Power Supply Configuration

Power supply modeLithium battery or power supply
Battery Operating Time60 hours (24V with no load)
Charging timeAbout 4 hours

Other indicators

Size115mm×45mm×180mm
Communication interfacespecialized three-core aviation plug
Weight0.8KG

Software Configuration:

PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.


Pressure Range Selection Table

1.Routine Pressure Range Selection Table

No.Pressure RangeTypeClass of accuracy
01(-100~0) kPaG0.02/0.05
02(0~60)PaG0.2/0.05
03(0~250)PaG0.2/0.05
04(0 ~ 1) kPaG0.05/0.1
05(0 ~ 2) kPaG0.05/0.1
06(0 ~ 2.5) kPaG0.05/0.1
07(0 ~ 5) kPaG0.05/0.1
08(0 ~ 10) kPaG0.05/0.1
09(0 ~ 16) kPaG0.05/0.1
10(0 ~ 25) kPaG0.05/0.1
11(0 ~ 40) kPaG0.05/0.1
12(0 ~ 60) kPaG0.05/0.1
13(0 ~ 100) kPaG0.05/0.1
14(0 ~ 160) kPaG/L0.02/0.05
15(0 ~ 250) kPaG/L0.02/0.05
16(0 ~ 400) kPaG/L0.02/0.05
17(0 ~ 600) kPaG/L0.02/0.05
18(0 ~ 1) MPaG/L0.02/0.05
19(0 ~ 1.6) MPaG/L0.02/0.05
20(0 ~ 2.5) MPaG/L0.02/0.05
21(0 ~ 4) MPaG/L0.02/0.05
22(0 ~ 6) MPaG/L0.02/0.05
23(0 ~ 10) MPaG/L0.02/0.05
24(0 ~ 16) MPaG/L0.02/0.05
25(0 ~ 25) MPaG/L0.02/0.05
26(0 ~ 40) MPaG/L0.02/0.05
27(0 ~ 60) MPaG/L0.05/0.1
28(0 ~ 100) MPaG/L0.05/0.1
29(0 ~ 160) MPaG/L0.05/0.1
30(0 ~ 250) MPaG/L0.05/0.1

Remarks: G=Gas L=Liquid


2.Composite Pressure Range Selection Table:

No.Pressure RangeTypeClass of accuracy
01±60 PaG0.2/0.5
02±160 PaG0.2/0.5
03±250 PaG0.2/0.5
04±500 PaG0.2/0.5
05±1 kPaG0.05/0.1
06±2 kPaG0.05/0.1
07±2.5 kPaG0.05/0.1
08±5 kPaG0.05/0.1
09±10 kPaG0.05/0.1
10±16 kPaG0.05/0.1
11±25 kPaG0.05/0.1
12±40 kPaG0.05/0.1
13±60 kPaG0.05/0.1
14±100 kPaG0.02/0.05
15(-100 ~160) kPaG/L0.02/0.05
16(-100 ~250) kPaG/L0.02/0.05
17(-100 ~400) kPaG/L0.02/0.05
18(-100 ~600) kPaG/L0.02/0.05
19(-0.1~1)MpaG/L0.02/0.05
20(-0.1~1.6)MpaG/L0.02/0.05
21(-0.1~2.5)MpaG/L0.02/0.05

Remarks:

1. Partial range can do absolutely pressure

  • Automatic temperature compensation range:(-20~50℃)
  • Pressure transfer medium requires non-corrosive