| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Toroidal Power Transformer |
|---|---|
| Brand Name: | Tiger |
| Model Number: | YT-110VA |
| Certification: | UL,ISO,CE,ROSH,CCC |
| Place of Origin: | China |
| MOQ: | 1000 |
| Price: | negotiation |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 20000PCS/Per Day |
| Delivery Time: | 15-25days |
| Packaging Details: | Cartons/ Pallets |
| Shipping Term: | FOB ShangHai/TianJin |
| Application: | Switching Power Supply, LED, Driver... |
| ODM OEM: | Accepted |
| Shipping: | By air or by sea |
| Insulation: | Class B |
| Name: | Toroidal Transformer |
| Company Info. |
| ANHUI TIGER CO,.LTD |
| View Contact Details |
| Product List |
Toroidal Transformer Ring transformer with secure electrical insulation 110VA

FEATURE&APPLICATION:
Low Magnetic Noise
High efficiency
Excellent Load Regulation
Easy Assembely
Very Low No-load losses and magnetizing Current
Half Size and weight Comparing to EI Transformer
Various Input options
100V/110V/117V/120V/220V/230V/240V,50/60Hz
Dielectric Strength 3KV,1min
100% Electric parameters Test
Power Range 20VA-5000VA Available According to
customer's requirement
Class B insulation System
Optional Single or Dual Primary
According to:
![]()
![]()
![]()
![]()
![]()
Datasheet
Execution Ring transformer with secure electrical insulation
Power 175VA
Insulation class B
Insulation class 3
Ambient temperature 40°C
Operating time 100% with auto-cooled
Insulation required
Primary – Secondary – Double
Primary - casing - Base
Secondary - casing - Base
Secondary 1 - secondary 2 - Bas
Test voltage
Primary – secondary Up=4250V AC (6000V DC)
Primary – casing– Up=2150V AC (3000V DC)
Secondary – casing – Up=2150V AC (3000V DC)
Secondary 1 – Secondary 2 – Up=1000V AC (1450V DC
Distances:
| air distance / mm | Creepage / mm | |
| Primary - secondary | 8 | 17,6 |
| Primary - casing | 5,5 | 7,7 |
| Secondary - casing | 5,5 | 7,7 |
Note Design for a possible overvoltage of 20%
Temperature switch C1B–B110 (110°C) , of TMC or similar
Observation
Windings 20V e 25V, and windings 46V e 42V, are not loaded togheter.
Windings of 42V must be designed in such a way that at 10A
concurrence for about 100ms the c.d.t is less than 3V (effective).
Because the housing is the external attachment, ad es.
Metal disc
Mounting: Ring base transformer on mounting plate with central through hole.
PIN positions/connections
Primary Molex Mini Fit Bushing case with 18 pin 5557 18R
Voltage Wire color Pin
0V white 9
230V blue 6
400V black 3
460V brown 1
Secondary Molex Mini housing for bushings with 6 pin 5557 6R
Voltage Wire color Pin
0V blue 4
42V brown 1
46V grey 5
0V white 6
20V green 3
25V black 2



|