| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Electrical Appliance Testing Equipment |
|---|---|
| Brand Name: | Sinuo |
| Model Number: | SN2212L-1K/2K/3K/4K |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Customized |
| Payment Terms: | L/C, , T/T, Western Union, MoneyGram |
| Supply Ability: | 20 sets per month |
| Delivery Time: | 30 Days |
| Packaging Details: | Plywood |
| Standards: | IEC UL VDE BS and etc. |
| Application: | Leakage current test |
| Output Capacity: | 1000/2000/3000/4000VA |
| Output Voltage: | 30.0V~300.0 |
| Current Upper Limit Range: | 0.1μA ~ 20.00mA |
| Current Lower Limit Range: | 0.0μA~20.00mA |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
Programmable Multi-standard Leakage Current Tester 1000VA 2000VA LCD Display
Standards & Clauses:
The tester conforms to IEC 60601-1: 2005+A1:2012, IEC 60950-1: 2005+A1:2009+A2:2013, IEC 60065: 2014, IEC 61010-1: 2010+A1:2016, IEC 60990:2016 and etc.
Samples and Restrictions:
Household appliances, electrical accessories, lamps, medical appliances, information and communication equipment,etc.
Application:
Various types of laboratories, home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes, etc.
Test Contents:
This tester can simulate following 6 types of MD networks:
■MD-A compliant to : IEC 60990
IEC 61010-1
■MD-B compliant to : IEC 60990
IEC 61010-1
IEC 60335-1
IEC 60950-1
IEC 60665
IEC 60598-1
■MD-C compliant to : IEC 60990
IEC 60598-1
■MD-D compliant to : IEC 61010-1
■MD-E compliant to : IEC 60950-1
IEC 61010-1
■MD-F compliant to : IEC 60598-1
Technical Parameters:
| Model | SN2212L-1K | SN2212L-2K | SN2212L-3K | SN2212L-4K |
| Input characteristics | Single-phase 50Hz, 60Hz 110 / 220Vac ± 10% | |||
| Output Capacity | 1000VA | 2000VA | 3000VA | 4000VA |
| Output voltage setting | 30.0V ~300.0V, Resolution: 0.1V / Step | |||
| Current upper limit setting range | 0.1μA ~20.00mA | |||
| Current lower limit setting range | 0.0μA~20.00mA | |||
| Wave detection method | DC/AC/AC+DC/AC Peak | |||
| Voltmeter | (0.0-250.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) | (0.0-300.0) V Resolution: 0.1 V Accuracy: ± (2% of reading + 2V) | ||
| Ammeter | 0.0uA-20.00mA Resolution: 0.1uA for 200.0μA range, 0.001mA for 2mA range, 0.01mA for 20mA range, Accuracy: ± (2% of reading + 2 words) | |||
| Test time | (0.1-999.9) seconds, 0 = continuous | (0.0,0.3~999.9)s, 0 = continuous | ||
| Intervals | (0.1-999.9) seconds, 0 = Test time is over, the tester stops automatically | (0.0-999.9) seconds, 0 = Interval time off | ||
| Rise time | (0.1-999.9) seconds, 0 = rise time off | (0.0-999.9) seconds, 0 = voltage rise time off | ||
|