| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Aluminum Single Point Load Cell |
|---|---|
| Brand Name: | inntronic |
| Model Number: | IPW2D |
| Place of Origin: | China |
| MOQ: | 1pc |
| Payment Terms: | L/C |
| Delivery Time: | 15-30 days |
| Price: | Negotiable |
| Type: | Single Point Load Cell |
| Capacity: | 7.2kg to 72kg |
| Output: | 2mv/v |
| Material: | Aluminum |
| Application: | static weighing |
| Interchangeable brand: | HBM |
| IP Protection standard: | IP67 |
| Accuracy grade: | C3 |
| Hysteresis error: | 0.0166 |
| Non-linearity: | 0.0166 |
| Company Info. |
| Innovation Electronic Co.,Ltd |
| View Contact Details |
| Product List |
− Accuracy class C3 with OIML-R60 test report
− Max. capacities: 7.2 kg ... 72 kg
− Off center load compensated(OIML R76)
− Degree of protection IP67(according to EN 60 529)
− Shielded connection cable
− optimized for dynamic weighing applications
− Connection cable in six wire circuit
− Different cable lengths
− Aligned output, suitable for
− Aligned output, suitable for connectionin parallel
| Type | IPW2D | ||||||
| Accuracy class1) | C3; C3MR | ||||||
| Number of load cell intervals (nLC) | 3000 | ||||||
| Maximum capacity (Emax)2)) | kg | 7.2 | 12 | 18 | 36 | 72 | |
Minimum LC verification interval (vmin) Accuracy class C3 | g | 1 | 2 | 5 | 10 | 20 | |
Temperature effect on zero balance (TK0) Accuracy class C3 | % v. Cn / 10 K | ±0.0194 | ±0.0233 | ±0.0389 | ±0.0389 | ±0.0389 | |
Minimum LC verification interval (vmin) Accuracy class C3MR | g | 0.5 | 1 | 2 | 5 | 10 | |
Temperature effect on zero balance (TK0) Accuracy class C3MR | % v. Cn / 10 K | ±0.0097 | ±0.0116 | ±0.0155 | ±0.00194 | ±0.0194 | |
| Max. platform size | mm | 380 x 380 | |||||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | |||||
| Zero balance | 0±0.1 | ||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K | ±0.0175 ±0.0117 | |||||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||
| Non-linearity (dlin)3) | ±0.0166 | ||||||
| Minimum dead load output return (DR) | ±0.0166 | ||||||
| Off center load error4) | ±0.0233 | ||||||
| Input resistance (RLC) | Ω | 300 ... 500 | |||||
| Output resistance (R0) | 300 ... 500 | ||||||
| Reference excitation voltage (Uref) | V | 5 | |||||
| Nominal range of excitation voltage (BU) | 1 ... 12 | ||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||
| Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | |||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||
Safe load limit (EL ), at max. 100mm eccentricity | % of Emax | 150 160 | |||||
| Lateral load limit (Elq), static | % of Emax | 300 | |||||
| Breaking load (Ed) | 300 | ||||||
| Weight (G), approx. | kg | 0.25 | |||||
Protection class according to EN 60 529 (IEC 529) | IP67 | ||||||
Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC | ||||||




|